corresponding power is from 17-19W (L), 19-23W (M), 23-27W (S) to 27-30W (H).
7.
AUTO OFF: Settings from 1- 24 hours. 0 means cancelling the settings. 3 seconds after your
settings, the timer function will be counted down to work by minutes and will display with
current humidity by turns for 5 seconds if having set the humidity level.
8.
HUMIDISTAT: Settings from 40 -95RH% by 5RH%. 0 means cancelling the settings. 3
seconds after your settings, the humidistat works. It stops when the current humidity is more
than the setting level, but the fan motor will keep working for 5 minutes. And will operate
when the current humidity is 2RH% less than the setting level.
9.
ANION: When the machine stands by, press the ANION button, it works whatever it is
humidifying. The fan motor works at the same time. If it is not humidifying, when the
ANION is off, the fan motor stops. But if it is humidifying, when the ANION is off, the fan
motor still works.
10.
Protection when waterless: When the tank is out of water, the Waterless lamp is on. And the
machine stops. Then the settings of TIMER and HUMIDISTAT will be cancelled. When
filling the water, it should be reset for the functions.
*Trouble Shooting Guide
Any trouble found in normal operation, please kindly refer to the following points:
Trouble
Possible reasons
Shooting Way
LED display is off
No power supply
Connect power supply
Not press ON
Switch on
LED display is on, no mist no
wind
No water in water tank
Fill water into water tank
Too much water in the water
basin
Pull out some water from the
water basin, closed the cover of
water tank tightly.
LED display is on, no mist but
with wind
Mist output is set on the lowest
level
Adjust the mist output
LED display is on, with water
but shows waterless
Floater is interrupted
Waver the floater, keep it free
Abnormal smell mist
New unit
Take out water tank, open cover,
let it stays 12 hours in cool
position
Dirty water or long time staying
water
Cleaning water tank, fill in clear
water
Mist fog is too small
Too much scale in the water
basin
Clean transducer
Water is too dirty or water kept
too long time in the tank
Clean water tank, change to
fresh clear water
Water is too cold
Add some warm water inside
Abnormal noise
Resonant in water tank when
water is too lower
Fill water tank with water