75
Cycling the Unit
The fans continue to free-wheel for several minutes when the unit cycles off. This is normal. If
the unit is furnished with an Xtreme low ambient control, the condenser fan also cycles on and
off during cooling. This maintains the head pressure on the compressor under Xtreme low
ambient conditions, and is normal. The bottom of the compressor stays warm even when the unit
is off to keep the lubricating oil warm and separated from the refrigerant
.
Setting the Remote Interface Controller
Normal settings are between 54 and 58 Deg F (12-14 Deg C).
Regulating the Wine Cellar Temperature
Wine cellars have a natural temperature gradient of approximately 5 to 10 degrees between floor
and ceiling. To increase or decrease the temperature in various zones, change the air flow
patterns.
To keep the entire wine cellar at the same temperature, set the remote interface controller to run
the supply fan continuously and not just when the cooling is operating. Set Setting 7 to Setting
1.
NOTE: To monitor the Cellar Temperature, place thermometers in various
locations in the cellar to monitor the temperature zones. Change the
temperature in various zones by shifting the air flow patterns.
Changing the Air Flow Direction
The optional grilles furnished with Wine Guardian are single directional. Rotate the grilles to
change the direction of the air flow.
When using multiple supply ductwork, it is necessary to balance the air flow between the
ductwork. If too much air flows though one duct but not enough air flows from the other duct,
install a damper or other restriction into the duct with too much air. That will force more air to
flow out the other duct
.
Содержание 99H0360-10
Страница 12: ...12 Xtreme Low Ambient Illustrations Fig 1 Fig 2 Pressure cutout timer 33c0185 00...
Страница 14: ...14 Condensing unit dimensions DS050 COND NO OPTIONS...
Страница 15: ...15 Refrigeration Illustration of the system See next page for magnified image...
Страница 16: ...16 Magnified Image of the Condensing Unit...
Страница 17: ...17 Wiring Diagram for DS025 DS050 WGS40 WGS75...
Страница 18: ...18 Wiring Diagram for DS088 and WGS100...
Страница 19: ...19 Wiring Diagram for DS200 and WGS175 Units...
Страница 20: ...20 Wiring Diagram for Replacement Fan Motor XR 115 230 Models...
Страница 21: ...21 Wiring Diagram for DS025 and WGS40 Condensing Unit...
Страница 22: ...22 Wiring Diagram for DS050 and WGS75 Condensing Unit...
Страница 23: ...23 Wiring Diagram for DS088 and WGS100 Condensing Unit...
Страница 24: ...24 Wiring Diagram for DS200 and WGS175 Condensing Unit...
Страница 25: ...25 Ducted Split Systems Specifications 60Hz Models DS025 DS050 DS088 DS200...
Страница 26: ...26 Ducted Split System Specifications 50 Hz Models WGS40 WGS75 WGS100 WGS175...
Страница 44: ...44 Install refrigeration piping per local codes and ASHRAE guidelines...