Central Air Purifier (CAP)
Owner’s Manual
For use with Models:
CAP3000, CAP5000
For safety and to ensure proper use carefully read
the contents of this manual before operating or
installing the unit.
Air Fantastic
Страница 1: ...ral Air Purifier CAP Owner s Manual For use with Models CAP3000 CAP5000 For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit Air Fanta...
Страница 2: ...lease contact us Mail Air Fantastic LLC Attn Customer Service 4406 Eagles Landing Dr Austin TX 78735 Web www airfantastic com E mail markm airfantastic com Phone 1 877 424 7326 Important Safety Instru...
Страница 3: ...4 F 180 F humidity 10 90 Non Condensing Do not operate unit in ambient temperatures above 150 F KEEP OUT OF REACH OF CHILDREN Only use the power adapters included with the purification system WARNING...
Страница 4: ...ld bacteria virus es and VOCs Proprietary UVC Lamps At the core of the Quad Ion Cell is a UVC lamp The 254 nm germicidal lamp kills mold bacteria viruses and breaks down VOCs They are American made la...
Страница 5: ...mps Induct Quad Ion Cell CAP System devices are intended for the removal of air borne contaminations of pathogens and or harmful molds and volatile organic compounds present in rooms or en closed area...
Страница 6: ...still red please contact an Air Fantastic representative Lamp Replacement Indicator Blue Solid The UVC lamp is within its two year life span No action is needed Blue Flashing The UVC lamp is outside...
Страница 7: ...ing premature system failure Air Fantastic has designed the perfect solution With the development of our proprietary Rotational UV Shield you can control how little or how much UV light is emitted fro...
Страница 8: ...running parallel with the duct ensuring air flow through the device When possible the UV Shield should be rotated the open position for optimal efficiency to expose more contaminants to UVC radiation...
Страница 9: ...yourself or others if you elect to install the device without utilizing qualified technicians Use the suggestions on page 6 to determine the optimal mounting location s To complete the installation pr...
Страница 10: ...four pins are in line with the Four Pin Connector Before inserting the CAP System use a 1 4 hex head screw driver to remove the four outer screws and pull off the Ballast Assembly from the Retainer Ri...
Страница 11: ...sive gasket will help secure the unit but the four hex screws are still required to secure the Ballast Assembly 7 Using a 1 4 hex head screw driver secure the power adapter with four self tapping 1 2...
Страница 12: ...Lamp Replacement light will begin to blink as a reminder that it s time to replace the Quad Ion Cell The CAP System utilizes a proprietary UVC lamp that can only be purchased from an authorized Air F...
Страница 13: ...until the four pins have completely disconnected from the Ballast Assembly 3 Using a 1 4 hex head screw driver remove the four screws securing the Quad Ion Cell and pull the Quad Ion Cell out from the...
Страница 14: ...allast Assembly should be orientated with the air flow label running parallel with the length of the duct to ensure the four pins are in line with the Four Pin Connector Optional mounting config urati...
Страница 15: ...dealer your purchase is AS IS which means Air Fantastic grants you no warranty and that you not Air Fantastic assume the entire risk of the quality and performance of this product including the entir...
Страница 16: ...rs since the Quad Ion Cell has been replaced Contact an Air Fantastic authorized dealer to purchase a new Quad Ion Cell If the above does not repair the symptom please contact an Air Fantastic Cus tom...