F. Configuration Parameters
air
avionics
F.7 Relay
F.7.1 Relay Mode
Description
Selects the mode of operation for the relay pins. The relay can be closed (contact between
relay input and output pins is established) or opened (contact between input and output
pins is interrupted) if targets are detected inside of the relay volume.
•
Item Code:
RELAYMODE
•
Valid Values:
UNUSED, CLOSE, OPEN
•
Default Value:
UNUSED
F.7.2 Relay Volume Range [m]
Description
Sets the horizontal dimension of the ’relay volume’ inside of which a target triggers the
relay to be opened or closed (depending on its configuration).
•
Item Code:
RELAYRANGE
•
Valid Values:
integer value, 0 - 1000000
•
Default Value:
1000
F.7.3 Relay Volume Vertical Range [m]
Description
Sets the vertical dimension of the ’relay volume’ inside of which a target triggers the relay
to be opened or closed (depending on its configuration).
•
Item Code:
RELAYVRANGE
•
Valid Values:
integer value, 0 - 1000000
•
Default Value:
100
70
AT-1
·
Installation Manual
·
rev. 4.0
·
2020/01/09