WEATHER-RESISTANT SUB STATION

NEM/C, NEM-A/C Series

NE-JA

Model:

INSTALLATION & OPERATION MANUAL

    A83090  1201  A

SYSTEM OUTLINE & COMPONENTS

Package Contents

NE-JA

  Door station (NE-JA) 
  Packet of screws
  Installation & Operation 
  Manual

Components
  NEM-n/c :    Press-to-talk master
  NEM-nA/C : Press-to-talk or VOX handset 
                      master (n=10, 20, 30 & 40)
  Other models;
    NEM masters with 50 ~ 120 calls

Weather-resistant door station style
Two-gang flush-mounting with stainless 
steel cover
LED staying lit while master is ringing

1. Loosen 2 screws on front cover.
2. Connect wires on back of NE-JA.
3. Mount NE-JA unit on 2-gang box.
4. Reattach front cover on NE-JA.

1. When exisitng chime wires are used, be sure to locate and disconnect the bell transformer.  
    Unit damage or electric shock could result.  Ask qualified personnel.
2. Do not change or alter NE-JA.  It can cause fire or electric shock.
3. The NE-JA is weather-resistant, but do not spray water directly on NE-JA station to  
    prevent electric shock.
4. Make sure wires are connected properly before plugging in power supply. Fire or electric
    shock could result. 

DISMANTLE PROHIBITIONS

GENERAL PRECAUTIONS

  –        mark indicates

caution statement (incl. danger and warning), which
is specifically shown inside. 

GENERAL PROHIBITIONS:

 –

 

       mark 

indicates contents which prohibit a specific 
action shown inside or attached. 

GENERAL INSTRUCTIONS

  –        mark indicates

contents which demand a specific action shown
inside or attached.

PRECAUTIONS ON INSTALLATION & WIRING

WARNING    

Negligence could result in death or serious injury.

NAMES & FEATURES

MOUNTING

RY-PA

NE-JA

NE-JA

NE-JA

NEM master

External device

Speaker/mic.

Master ring LED

Cover mount screws

CALL button

Stainless   

steel cover

NBY-4A

NAR-2A

: PS-24E. PS-2410A (USA; for up to 20 subs) 

PS24

PS24

2

2

2

1

1

2

2 wires homerun

1

1

1

1

The NE-JA is weather resistant sub station designed for use with the 
NEM system. The unit is equipped with an option for an external output 
contact closure when the sub station places a call (relay required). The 
NE-JA flush mounts in a 2-gang box, and has a stainless steel cover.                                       

Important: 
It is suggested to connect an NE-JA('s) in a 
homerun manner, particularly when corridor 
light is installed. To secure brightness of the 
corridor light, use thicker wire possible and limit 
wiring within 60% range of the Distance Chart 
on Page 2.

When an NE-JA('s) is connected to a common 
E line, do not exceed two NE-JA's per E line, as 
the calls will not be fulfilled if placed from three 
NE-JA's (or more) at the same time.

(*) Important: 
It is suggested to connect NE-JA in homerun 
manner. Otherwise, do not exceed two NE-JA's 
on common E wire.

2-gang box

2 screws

(supplied)

Front cover

(Stainless steel)

2 front screws

83.5mm
(3-5/16")