- INSTRUCTIONS -

The NDR Lamp Memory and External Control System is designed for communication between a central master
station and remote intercom stations.  In addition to communication to remote locations, an external device can
be activated, such as activating a CCTV camera when the associated sub station is selected, or selectively
controlling the corresponding door strike or maglock.  All other features, functions, and components are the same
as the standard NEM system.

WIRING DIAGRAM:     SYSTEM USED FOR CCTV CAMERA CALL-UP

NDR

NDR Lamp Memory Master Station with External Control Capability

NDR-10

NDR-20

NDR-30

NDR-40

NDR-10A

NDR-20A

NDR-30A

NDR-40A

Individual Components for System:

NDR-

n     

Master station with selective contact output capability (10, 20, 30, 40)

NDR-

nA

Master station w/handset and selective contact output capability (10, 20, 30, 40)

ND-20AS

20-call Add-on Selector with selective output capability

ND-40AS

40-call Add-on Selector with selective output capability

RY-PA

Relay for selective output (1 per station requiring external contact)

PS-2410A

24V DC, 1A Power Supply for 10-20 station systems

PS-24E

24V DC, 2A Power Supply for 30-40 station systems

N-series

Any model sub station with NA- or NE- prefix

IMPORTANT:

1. RY-PA must be used for each additional contact

 to isolate AC voltage from the intercom circuit.

2. Extra contact connections and L are on separate

 terminal block.  NDR-30/40 have two terminal blocks.

Special
Order
Products

1
2
3
~

20

E

H

+

-

NDR-20A

+

-

PS-2410A

NE-NVP

Red

Blk

Grn
Grn

Leave green

jumper intact

Red

Blk

Grn

NA-NE

1

2

3
~
20       L

1

2

Blk

Wht

NE-DA

RY-PA

#1

RY-PA

#2

RY-PA

#3

BLK

BLK

BLK

YEL

YEL

YEL

External

Terminal Block

Normally Open contacts remain
closed as long as master has sub
station selected.

Closure for Station #1

Closure for Station #2

Closure for Station #3

Pg. 1

1

          L

2

RY-PA

#1

BLK

H

+

-

RY-PA

#2

NEM Master

RY-PA

#1

RY-PA

#2

BLK

BLK

BLK

YEL

Momentary closure #1

YEL

Constant closure #1

YEL

Momentary
closure #2

YEL

Constant
closure #2

Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
1 Diode (1N4001)

DUAL FUNCTIONS FROM EACH CHANNEL:

Terminal Block

NDR TERMINAL DEFINITIONS:

+

Positive 24V DC

-

Negative

1~40

Station number

E

Common communication

H

Positive output for constant closure

L

Positive output for selective closure