OPERATION NOTES:
1. Only one master can be used at a time.
2. If both masters are activated, a feedback will be heard through the system when either
TALK button is pressed.
3. If feedback occurs, press the OFF button on one of the LEM-1DL masters.
INSTALLATION GUIDELINES:
1. Use 2 conductor wire from the door station to the first master, then to the second master.
2. Install the units at the desired locations.
3. Separate PT-1210N power supplies are required for each master station.
4. Install the bare wire leg of the component module directly onto the "1" terminal of the LEM-1DL's.
5. Attach the wire coming form the "1" terminal of the LE-D to the colored wire end of the component modules at both
masters. (The component modules will easily fit within the space available.)
6. Connect the "E" terminals between the door station and master stations.
7. If door release is included, use a separate 2-conductor wire from the "EL" terminals of the masters through an AC
transformer and to the door strike.
8. The EL-9S is designed for a standard wood framed door, and for light and medium usage. If a different type of door is
used, install a strike appropriate for the door.
9. The door release button on the master station is a "Normally Open" contact closure.
Component
Module*
Component
Module*
PT-1210N
PT-1210N
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
DAK-2S Instr.
0301bkjd
LE-D
1
E
-
Door
Master #1
Master #2
EL-9S
Please read and understand all
instructions before installation.
IMPORTANT!!!
Each master REQUIRES an individual PT-1210N power supply.
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
E-MAIL: [email protected]
1
E
+
-
EL
EL
LEM-1DL
1
E
+
-
EL
EL
LEM-1DL
DAK-2S
Dual Adaptor Kit for 2 Station Systems
DAK-2S Includes: 2 component modules
- DAK-2S with LEM-1DL SYSTEM -
* Install bare wire
end to "1" terminal
(DAK-2S contains two
component modules)