5-37
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
5.5.5. Contact setting
Step 1.
Click on the Contact I/O tab. The setting screen is displayed.
Step 2.
Set each item of "Contact input."
(1) Contact No.
(Can't be edited.)
The Multi interface unit's contact input terminal number.
(2) Mode
Select the contact input's operation mode. The setting contents differ depending on the mode selected
here.
Input interlock level: Select this item when closing the contact output terminal in synchronization with
the contact input terminal as shown below.
Input interlock edge: Select this item when closing the contact output terminal in synchronization with
the contact input terminal as shown below.
[Input interlock level]
ON
Input
OFF
ON
Output
OFF
[Input interlock edge]
ON
Input
OFF
ON
Output
OFF
50 ms
50 ms
50 ms
50 ms