Aiphone 83873900 0602 E - Продукт, который включает в себя установочное руководство и руководство пользователя. Вы можете загрузить бесплатные руководства на {веб-сайте}, чтобы установить и настроить этот продукт. Легко и просто!
HEALTH CARE COMMUNICATION SYSTEM
for Nursing Homes & Health Care Facilities
NHX SYSTEM
83873900 0602
E
– 1 –
INSTALLATION MANUAL
c
Страница 1: ...HEALTH CARE COMMUNICATION SYSTEM for Nursing Homes Health Care Facilities NHX SYSTEM 83873900 0602 E 1 INSTALLATION MANUAL c...
Страница 2: ...stallation Wiring 13 21 Mounting location Wiring Cable Power supply Power off system resetting Zone light installation 13 Setting Station 1 10 on Sub stations 14 Initializing NHX 80X for Sub stations...
Страница 3: ...t that varies in temperature in front of air conditioner inside a refrigerated area etc Places subject to moisture or humidity extremes Places subject to environmental conditions such as oil dust chem...
Страница 4: ...n may have urgent bathroom call button ea 3 wires Corridor light mounted on 1 gang box 3 wires Gang box may be used for junction of 3P Trunk cable 2 NHX 80X Central Control Unit 50 or 80 call station...
Страница 5: ...4A NHR 3A 4 up to 4 Do not connect two power supplies in parallel NHX 80X CCU Zone lights NHR SP Duty station NHX 50M NHX 30G Master Add on Staff call area Common area Restrooms Bedside sub area multi...
Страница 6: ...A Single call sub station NH 2SA A NH 2SA Dual call sub station Corridor lamp sub NHR 3TS Common area call station used w NHR 7A Bathroom pullcord NHR 3TS Urgent staff call sub station used w NHR 7A m...
Страница 7: ...orridor lamp in common area for urgent bathroom call or in the hallway for urgent staff call Urgent call switch cannot be used alone Contact Ratings DC 24V 10mA to max 20mA min 5mA or more Hand held c...
Страница 8: ...12 Speaker 13 Directory 14 Sub call in LED 15 Sub selector button 16 Power on LED 17 Mic 18 OFF button 19 TALK button 10 TONE OFF button 11 Attendance LED 12 RECEIVE VOL 13 TONE VOL See OPERATIONS se...
Страница 9: ...routine call only while the bathroom and cord out trouble call can be cancelled at the site NH 2SA A 2 gang mounting 1 Speaker mic 2 CANCEL button for Routine call only 3 TALK mode LED 4 Master RING...
Страница 10: ...460 18 1 8 13 3 8 3 7 8 2 NAMES FEATURES 1 24V DC output terminals 2 Terminal for grounding 3 120V AC input power cord plug of approx 6 3 1 9m long 4 Cover of Terminal section PS 24E PS 2420 Single g...
Страница 11: ...cover 4 Red lamps inside 2 5 gang mounting holes 1 Master RING LED 2 Pull lock switch Tie up the pullcord supplied NHR 3A 4 NHR 8A 45 28 116 1 4 16 9 1 120 4 4 3 8 1 1 4 3 116 120 1 2 3 4 16 9 4 4 3 4...
Страница 12: ...lights 8 Three types of calls with distinct tone and light signalling 1 Routine Call 2 Urgent Call from bathroom common area bath or urgent call station 3 Cord out trouble call from bedside Calls are...
Страница 13: ...el or twisted pair cable 22AWG or heavier UL Listed Power supply For NHX 80X CCU use the power supply exclusively designed as listed below PS 24E or PS 2420 Rated input 120V AC 50 60Hz Rated output DC...
Страница 14: ...ll in OFF position Move to upper ON position according to the Chart Example 7 1 2 4 7 Do not assign the same number for more than one sub within a trunk Otherwise system will malfunction FIG 2 BLOCK 1...
Страница 15: ...on while holding down OFF button on front panel The NHX 50M enters testing mode Check the sub stations throughout system as follows From sub 1 of the first row the LED is lit and goes out if the sub i...
Страница 16: ...on LED control 3 Zone light connection to sub s ZL terminal Z1 to Subs of zone 1 Z2 to Subs of zone 2 Z3 to Subs of zone 3 Z4 to Subs of zone 4 A sub cannot have more than one zone indication to Zone...
Страница 17: ...ng to bathroom pullcord corridor lamp zone light Plug in the supplied connector for wiring to NHX 80X CAUTION When NHR SP Duty Station is installed remove the Shorting Connector CN104 on NHX 80X CCU P...
Страница 18: ...t is necessary only when wires to NHR SP are broken g p g p To silence the tone plug in the shorting connector until NHR SP is y y y y restored to normal operation p g p g WIRING DIAGRAMS 1 NHX 80X CC...
Страница 19: ...ne lights 3 4 Lamp Rated DC 24V 100mA each lamp Total 400mA per NHR 3A 4 PS24 PS24 Zone light NHR 3A 4 NHX 80X 5 2 1 2 3 4 5 2 5 5 1 1 2 2 3 3 1 3 4 1 1 2 2 3 3 1 2 3 4 2 2 3 3 4 1 1 2 2 3 3 1 2 3 4 1...
Страница 20: ...3TS NH 1SA A NH 1SA NH 2SA A NH 2SA or NHR 3TS PS24 PS24 Power supply PS 24E or PS 2420 DC24V 2A G B B PS24 G A A Z4 Z2 81 82 83 84 85 86 41 42 43 44 45 46 To Subs block 8 Z3 CCU Z1 ZL 51 52 53 54 55...
Страница 21: ...L RL E TC TL White Red Brown Green Yellow Blue Blue Green Yellow Blue Orange Red LED CN2 CN1 Brown Red Orange Orange LC terminal is not used not shown NHX 80X NHR 3TS NHR 7A NHR 7A NHR 7A NHR 7A CCU A...
Страница 22: ...TL E ZL LC Z1 11 12 13 14 15 16 3P or 4P 3P 2 3P or 4P 3 or 4 3 3P 2 3P 2 NHR 4A NHX 80X CCU NHR 7A common bathroom NHR 4A NHR 7A Brown Orange Red Orange Brown Red Orange Yellow Green Blue Purple Bro...
Страница 23: ...A NH 2SA A 1 2 3 3P 2 3P or 4P 3 or 4 3 3P 2 5 4 6 3P 2 3P 2 2 white lamps NHR 4A One red lamp NHR 4A NHX 80X CCU NHR 7A Left row Right row common bathroom Subs trunk line 1 Requried only when NHR 7A...
Страница 24: ...ed to wood backboard Conduits optional NHX 50M console Door Front cover PS 24E or PS 2420 NHX 80X Chassis NHX 80X should be mounted on either 3 gang box or non combustible mounting plane wall Mounting...
Страница 25: ...e socket Mount the cover at 3 points which connects NHX 50M NHX 30G units together To CN1 Socket on back of NHX 50M 10 pin plug Terminal cord 6 7 2m long approx Wire nuts NHX 80X cable As shown connec...
Страница 26: ...protecting from being pulled or crushed e Corridor lamp for bedside sub Cover Screws 4 2 gang box Box must be more than 2 50mm deep 3 5 16 83 5mm NH 2SA A in this illustration SINGLE GANG BOX for corr...
Страница 27: ...A A or NH 2SA A bedside sub or NHR 3TS common area call station 2 Mount NHR 7A on 1 gang box 3 For bathroom call tie up pullcord supplied NHR 3A 4 1 Put number labels 1 4 on lamp covers 2 Terminate 5...
Страница 28: ...tion is finished Receiving a Bathroom Pullcord Call or call from NHR 3TS sub At NHX 50M At site When a cord is pulled at Bathroom 1 Single chime tone rings on NHX 50M every 1 8 seconds together with L...
Страница 29: ...d will light on the NHX 50M until all calls are answered Other operations 1 Call in during communication will activate both call tone LED 2 While call tone is muted call ins will be annunciated by ton...
Страница 30: ...TS At NHR SP Duty station When Master received Routine call Single chime every 6 sec CALL blinking every 2 sec Urgent call Single chime every 2 sec CALL double blinking every 1 8 sec Cord out trouble...
Страница 31: ...and tone at NHX 50M after each previous call is concluded Momentarily hang up handset and the next call tone is audible The sixth call will not illuminate on NHX 50M nor on Corridor lamp Only zone lig...
Страница 32: ...m call room or common area or NHR 3TS staff call urgent call 3 Routine call Wiring Use UL Listed twisted pair only copper conductor cable for all wiring 6 3P looped CCU to a trunk line of 10 subs 10 5...