Entrance Station 
(Integrated type)

Содержание 0311 A OI

Страница 1: ... UnitType Entrance Station IntegratedType Security Guard Station Entrance Station Unit type Security guard station 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M O 1 0 9 Y X W Z 7 R Q P S 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M O 1 0 9 Y X W Z 7 R Q P S Entrance Station Integrated type ...

Страница 2: ...t in injury to the ears General Precautions 1 The unit turns inoperative during power failure 2 In areas where broadcasting station antennas are close by intercom system may be af fected by radio frequency interference 3 Keep the unit more than 1 m away from radios or TV sets 4 Be careful about where the unit is used as use of computers televisions or radios near the unit may affect transmission f...

Страница 3: ...Calling another security guard station 12 Missed call 13 Call transfer Communication transfer 13 Emergency call 14 4 Setting list Setting list 15 5 CHANGING SETTINGS ENTRANCE STATION Setting method 16 Display language selection 17 Guidance language selection 17 Changing the ID code 18 Access code setting 18 Changing resident information 19 Setting messages and the standby screen 20 Adjusting scree...

Страница 4: ... Combination examples for entrance stations Camera module GT VA GT SW Name scrolling module Ten key module Switch module Forward search button or move the cursor to the right Cancel button or set and return Back search button or move the cursor to the left Call button or set and move forward Display 10 key 0 to 9 Directory card Call button Speech module GT NS V VIGIK compatible GT NS GT 10K Camera...

Страница 5: ...ll button Sensor Speaker Display 10 key 0 to 9 VIGIK GT DMV only available in France Handset Hearing aid T mode compatibility symbol 1 This button is not used Light button Door release button USB terminal B type 1 This unit emits an electromagnetic field for hearing aids with T mode to produce clear audio Off hook LED orange Call tone volume switch low medium high Forward search button or move curs...

Страница 6: ...ne Audio guidance will be heard depending on the settings Calling with the name scrolling module or GT DMV GT DM Display the residential station to be called 1 Display using scrolling to search 1 In the standby mode use the and buttons to display the room number and resident name Use the and buttons to search for the desired residential station Depending on the settings the resident name may only ...

Страница 7: ...umber and name for the resident whose initial corresponds to the entered letter will display Depending on the settings the resident name may only display NOTES 1 Pressing the or button for approximately 2 seconds will dis play the resident names in succession 2 If both room number 111 and 1111 exist the resident name for room 111 will be displayed when 1 1 1 is entered and the resident name for ro...

Страница 8: ...tton You will hear a call tone Audio guidance will be heard depending on the settings 1 In the standby mode enter the access code 4 to 6 digits after entering on the 10 key Audio guidance will be heard depending on the settings 2 The door is released 5 When the other person answers communication starts and the talk indicator lights up Audio guidance will be heard depending on the settings 6 When t...

Страница 9: ... ends automatically after approximately 3 minutes 2 Door release is activated at the entrance station 2 The outside light at the entrance will only turn on for the preset dura tion of time 2 Lift the handset to respond Calling from an entrance station Door release Light control 3 1 3 2 3 3 3 OPERATIONS SECURITY GUARD STATION With the expanded system the display number of the entrance station varie...

Страница 10: ...V 6 N M O 3 E D F 1 R Q P S 7 Y X W Z 9 0 2 B A C 4 H G I 5 K J L 8 U T V 6 N M O 3 E D F 1 R Q P S 7 Y X W Z 9 0 2 B A C 4 H G I 5 K J L 8 U T V 6 N M O 3 E D F 1 R Q P S 7 Y X W Z 9 0 2 B A C 4 H G I 5 K J L 8 U T V 6 N M O 3 E D F 1 R Q P S 7 Y X W Z 9 0 1 Lift the handset and press the 10 key button 3 Press the button to communicate with the entrance station If there is no corresponding entran...

Страница 11: ...rolling Calling residential stations 3 7 NOTES 1 Pressing the or button for approximately 2 seconds will dis play the resident names in succession 2 If both room number 111 and 1111 exist the resident name for room 111 will be displayed when 1 1 1 is entered and the resident name for room 1111 will be displayed if 1 is entered one more time 3 Stations can be made to display in order by room number...

Страница 12: ...utton Making a call using the ID After pressing and 1 on the 10 key enter 0 plus the security guard station ID number 1 to 4 and then press the button You will hear a low volume call tone from the handset Making a call by security guard station name scrolling Use the and buttons to search security guard station names by scroll ing Making a call by entering the security guard station number Enter t...

Страница 13: ...rance station number 2 Lift the handset to communicate with the entrance station 3 When transferring a call to the called residential station press the button 4 After the residential station answers hang up the handset to establish communication between the entrance station and the residential sta tion When there is no one at the residential station hang up the handset and pick it up again to comm...

Страница 14: ...n another security guard station cannot interrupt An in use tone will be heard from the handset of the security guard station 2 The emergency alarm is given priority even when the system is in use Alarms can be activated at the same time for up to 5 units This excludes GT 2C L and GT 2C 3 When a security guard station has received multiple emergency alarms an arrow will be shown to the right of EM...

Страница 15: ... Change the greeting message 20 PROGRAMMING Perform link settings TRANSFER DATA Transfer link information to another entrance station or security guard station VERIFY PROGRAM Perform a link check SCROLL SPEED Set the scroll speed for display messages and resident names etc MONITOR ENTRANCE Select the setting for monitoring with the entrance station camera from a residential station CALL IN DISPLAY...

Страница 16: ...changing settings use the GT NS V GT NS or GT DMV GT DM program mode Program Mode 1 In the standby mode enter the 4 digit ID code after entering and on the 10 key Initial setting 1111 2 The RE ENTER ID CODE is displayed Re enter and the 4 digit ID code 3 The first menu item is displayed Use the and buttons to select the desired menu item 4 When quitting the program mode select QUIT and press the bu...

Страница 17: ... ESPAÑOL NEDERLANDS ITALIANO MENU ENTER SELECT LANGUAGE GUIDE LANGUAGE CHANGE ID CODE GUIDE LANGUAGE NO GUIDANCE ENGLISH FRANÇAIS ENTER Next menu item Start the program mode with the GT NS V GT NS or GT DMV GT DM and select SELECT LANGUAGE Select English French German Spanish Dutch or Italian Start the program mode with the GT DMV GT DM and select GUIDE LANGUAGE Select English French German Spanis...

Страница 18: ...t is displayed after NO OF DIGIT Set a digit from 4 to 6 Enter the digit using the 10 key or with the GT DMV GT DM select it by using the and buttons and then press the button 3 ACCESS CODE 001 will be displayed Up to 500 access codes can be set Select access codes from 001 to 500 Enter the digit using the 10 key or with the GT DMV GT DM select it by using the and buttons and then press the button...

Страница 19: ... 9 on the 10 key and then press the button Room numbers can have up to 6 digits 4 Press the button The display will return to the room number entry screen 5 To newly register another residence or edit information enter the room number Press the button to return to the menu 3 The room number is displayed If the resident name has already been registered it will also display Enter or edit the residen...

Страница 20: ...0 LETTERS ENTER Ex WELCOME TO Next menu item GT DMV GT DM Start the program mode and select STANDBY SCREEN Select from the following in the standby screen display Greeting message Operation message Original picture Uploading an original picture These items are set when a unit is installed When making changes consult with an qualified installer Changing the greeting message GT NS V GT NS GT DMV GT D...

Страница 21: ...E Current search order Next menu item Screen brightness can only be adjusted with the GT DMV GT DM Start the program mode and select BRIGHTNESS Set a digit from 0 to 9 0 Dark 9 Bright Select either name order or room number order for searching at the entrance station GT NS V GT NS GT DMV GT DM Start the program mode and select SORT SETTING Switching between name order or room number order occurs e...

Страница 22: ... Current ID code CHANGE ID CODE 0123 ID code after change Start the program mode and select SELECT LANGUAGE Select English French German Spanish Dutch or Italian 1 Start the program mode and select CHANGE ID CODE 2 The current ID code is displayed Enter the new 4 digit ID code after entering on the 10 key 3 Press the button to return to the menu Display language selection Changing the ID code 6 2 ...

Страница 23: ...er residence or edit information enter the room number Press the button to return to the menu 3 The room number is displayed If the resident name has already been registered it will also display Enter or edit the resident name Resident names can have up to 32 characters Press to delete the room number and resident name Up to 4 names can be registered for the same residence Press on the 10 key to d...

Страница 24: ...tral household cleanser Do not use any abrasive cleaner or cloth Repair requests If there is a system malfunction unplug the power supply and contact a qualified technician for service 7 TECHNICAL PRECAUTIONS 8 SPECIFICATIONS GT DA L GT DA Dimensions 93 H 108 W 49 D mm 3 5 8 H 4 1 4 W 1 7 8 D inches Weight GT DA L Approx 160 g 0 35 lbs GT DA Approx 150 g 0 33 lbs GT VA Imaging element Complementary...

Страница 25: ...een the equipment and receiver Consult the dealer or an experienced radio TV technician for help WEEE indicates applicability to the EU Aiphone warrants that its products have no material or workmanship defects under normal use conditions for two years after delivery to the end user Aiphone will perform repair or replacement free of charge if the product is defective and the warranty applies to th...