background image

 
 

  SCC10APWM Solar Charge Controller Installation and Operation Manual 

AIMS POWER 

9550 Gateway Dr 

Reno, NV 89521 

Tel:(775)359-6703

    Fax:(775)359-6753 

Email: [email protected]   

[email protected] 

READ MANUAL BEFORE USING THIS PRODUCT 

1. PRODUCT INTRODUCTION

 

This AIMS Power PWM solar charge controller is designed to charge and monitor your LiFePO4 battery 
to achieve a longer life cycle. It also trickle charges AGM, GEL and lead acid battery technologies.   
Using the latest charging technologies combined with state of charge monitoring, this product allows 
for optimal battery maintenance and efficient solar power monitoring. The LCD screen displays 
operating modes such as; state of charge, voltage, and current. The product also displays symbols for 
easy user interface. 

 

Integrated data logger energy meter 

Automatic detection of voltage 12 or 24 Vdc 

PWM control   

Automatic load reconnection   

Listed to UL 1741 & CSA 22.2 No. 107.1   

Adjustable charge voltage   

 

2. INSTALLATION

 

Install the charge controller near the battery on a

 stable

 surface. This surface should be solid, even, dry 

and nonflammable. The battery cable should be as short as possible and have a cable diameter size to 
minimize loss, e.g. 4 mm²  at 20 A and 6ft in length (16 AWG). 
Do not install the controller in direct sunlight. 
To ensure adequate airflow around the controller, allow a 4 inch clearance around the unit. The 
temperature at the installation site may never fall below or exceed the maximum

 

permitted ambient 

temperature range. 
Connect the individual components to the symbols provided on the bottom of controller.

 

 

Follow the following connection sequence during installation: 
1. Connect the battery to the charge controller - positive and negative 
2. Connect the solar module to the charge controller - positive and negative 
3. Connect the DC load to the charge controller – positive and negative (optional) 
 
The reverse order applies when uninstalling. 

NOTE! The automatic detection of 12V or 24V systems functions properly only if this sequence 
order is followed. An improper sequence order can damage the battery! 
 
*There are no user serviceable parts inside the charge controller. Do not disassemble or attempt 
to repair the unit. Contact manufacturer.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

3. OPERATION

 

3.1 Description of LCD symbols

 

 

3.2 Description of Button Function 

 

Button for switching display windows 

 Enter/exit the setting (press for 5 seconds)

 

 

Adjust parameters up 

 Restore factory setting in each parameter (press for 5 seconds)

 

 

Adjust parameters down (minus) 

 Click this button to switch the load in main display 

window

 

3.3 View and Set the Parameters 

The controller will auto display the “battery voltage” main display once power is connected (follow 
correct sequence from INSTALLATION instructions. This is the main display window. Use the button 

 

  to switch between different display windows. If the parameter can be set, press the button 

  (>5 seconds, numbers start flashing) to enter the setting, then press the 

  or 

  to 

select the setting, after that, press the button (>5 secs) 

  again to exit the setting (numbers stop 

flashing).

 

 

 

 

   

 

 

 

 

 

Battery voltage 
(main display)

 

 

 

Solar panel 
voltage

 

 

Solar panel 
charging current

 

 

 

 

 

 

 

 

 

 

 

 

High voltage 
disconnection(HVD) 

Float voltage

 

 

Accumulative sum of 
kwh drawn by load 

 

Accumulative sum   
of recharged kwh 

 

Load discharging 
current 

 

 

 

 

 

 

 

 

 

 

 

Low voltage 
reconnection(LVR) 

 

Low voltage 
disconnection(LVD) 

 

Load working 
mode 

 

 

 

 
 

 

 

 

 

 

 

 

 

3.3.1 Battery voltage (main display) 

Displays the battery voltage measured by the controller. Also, it displays the 
charge and discharge status, battery capacity. 

 

3.3.2 The load ON/OFF control 

In the main display window, click the button

  to ON/OFF the load. The button 

doesn’t have this feature in the other interface.

 

 

 

 

 

3.3.3 Environment temperature   

Displays the ambient temperature of the controller. 

̊

 

 

3.3.4 Solar panel voltage   

Displays the solar panel voltage measured by the controller. 

 

3.3.5 Solar panel charging current   

Displays the charging current from the solar panel. 

 

3.3.6 Load discharging current   

Displays the discharging current drawn by load. 

 