36
ANET1553
Users
Manual
4.7.2 Time Tag Methods
The IRIG-IN and IRIG-OUT signals shall be connected depending on the time tag
method used as shown below.
a.
Single AIM-Module no external IRIG-B source
-
No connection required
b.
Multiple AIM-Modules with no common synchronization requirement
-
No connection required
c.
Single or multiple AIM-Module(s) with external IRIG-B source
-
Connect external IRIG-B source to IRIG-IN and GND of all modules
d.
Multiple AIM-Modules with no external IRIG-B source internally
synchronized
-
Connect the IRIG-OUT signal and the GND of the module you have
chosen as the time master to all IRIG-IN signals (including the time
master).
4.8 Powering the ANET1553
In general any external power supply (wall adapter) providing 9V
DC
…15V
DC
can be
used to power the ANET1553.
An external 12V
DC
power supply is recommended and is provided with a ANET1553
module. All onboard voltages are generated from this voltage.