Page 16
10
Menu - Advanced Functions
Menu
Pressing the key marked Menu selects the System Menu screen.
This provides access to advanced options and functions. When the system menu is
displayed, setting of output parameters is not possible but operation of the output
On/Off keys is unaffected.
Each item of the system menu is selected by using the two arrow keys, or by turning
the spin wheel until the desired line is highlighted, and then pressing the Select soft
key. This selects a menu screen relating to the function selected.
Help Text
Alternatively, pressing the Help soft
key provides some on-screen
explanation of the highlighted function.
10.1 Setting Voltage Tracking
Menu > Voltage Tracking Setup
By default all three outputs are
completely independent. However, it
is possible to make the voltage of an
output always equal to the voltage set
on another output. This is called
voltage tracking.
Tracking voltages can be useful in
setting up adjustable voltages of equal
or opposite polarity, or when outputs
are wired in parallel or in series.
Three alternative voltage tracking arrangements are possible:
Mode 1
Output 2 tracks Output 1.
Mode 2
Output 2 and Output 3 both track Output 1.
Mode 3
Output 3 tracks Output 2.
The controlling output is described as Master, whilst a controlled output is described as Slave.
Voltage tracking can only be selected when the voltage range for the Slave output is equal to or
higher than that of the Master output.
The tracking condition is displayed on the top line of the display, see section 8.
When tracking is set, changing the range of either the Master or Slave output will cancel
tracking regardless of the direction of the change.
Содержание MX100T
Страница 1: ...MX100T MX100TP Triple Output Multi Range DC Power Supply INSTRUCTION MANUAL ...
Страница 34: ...Page 33 Status Model ...
Страница 46: ......