Страница 1: ...UM_SB402 VG_v1 2_022119 SB402 VG Storage Server Barebone User s Manual...

Страница 2: ...ling the Motherboard 15 2 4 1 Installing the Motherboard 15 2 5 Removing and Installing the Power Supply Unit Module 16 2 5 1 Removing the Power Supply Unit 16 2 5 2 Installing the Power Supply Unit 1...

Страница 3: ...3 6 HDD Backplane 2 Bay 40 3 6 1 Placement 40 3 6 2 Connector Location 41 3 6 3 Connector 41 3 6 4 LED Indicator 42 3 7 HDD Backplane 12 Bay 43 3 7 1 Placement 43 3 7 2 Connector Location 44 3 7 3 Con...

Страница 4: ...ket Configuration 68 4 4 4 PCH Configuration 72 4 4 5 H2o IPMI Configuration 76 4 4 6 H2o Event Log Config Manager 77 4 5 Security 78 4 5 1 Security 78 4 6 Power 79 4 6 1 Power 79 4 7 Boot 80 4 7 1 Bo...

Страница 5: ...Copyright 2018 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 6: ...ent Release History Release Date Version Update Content January 2018 1 Released to public January 2019 1 1 1 New cover 2 QIG update 3 BMC update 4 Hardware Update Febuary 2019 1 2 Safety Instruction u...

Страница 7: ...e for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is provi...

Страница 8: ...a stable surface when install A drop or fall could cause injury Please keep this equipment away from humidity Carefully mount the equipment into the rack in such manner that it won t be hazardous due...

Страница 9: ...er cord or plug is damaged 2 Liquid has penetrated the equipment 3 The equipment has been exposed to moisture 4 The equipment does not work well or will not work according to its user manual 5 The equ...

Страница 10: ...ngs This chapter elaborates the overall layout of the server motherboard including multifarious connectors jumpers and LED descriptions These descriptions assist users to configure different settings...

Страница 11: ...are damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify t...

Страница 12: ...ve activity System ID Drive Bays External 3 5 hot swap 36 2 5 hot swap 2 7mm rear Backplane and 3 SFF 8643 connectors and 3 SFF 8643 connectors Expansion Slots PCIe 3 0 System BIOS BIOS Type Insyde UE...

Страница 13: ...tilization In addition to the noteworthy features of the barebone SB402 VG provides immediate and efficient management with Onboard Baseboard Management Controller and greater I O extension Featuring...

Страница 14: ...l System LED Indicator and switch Rear Panel 24 x 3 5 hotwap drive tray 12 x 3 5 hotswap drive bays 6 x PCIe 3 0 slots RJ45 module 2 x 2 5 hotswap drive bays Power Button System Power LED System ID Sy...

Страница 15: ...5 Chapter 1 Product Features SB402 VG User Manual Top View...

Страница 16: ...you need to prepare before installation a T20 Torx screwdriver ESD wrist strap mat and conductive foam pad CAUTION The pins of the processor socket are vulerable and easily susceptible to damage if f...

Страница 17: ...r board includes two processor sockets LGA 3647 supports one or two of the Intel Xeon Processor Scalable Family and has a Thermal Design Power TDP of up to 165W on selected models PHM Processor Heatsi...

Страница 18: ...r socket assembly the four heat sink torque screws must be secured in the following order as shown below Processor Heat Sink Top View with Screw Tightening Order CAUTION Failure to tighten the heatsin...

Страница 19: ...Avoid moving the heatsink after it has contacted the top of the CPU Too much movement could disturb the layer of thermal compound causing voids and leading to ineffective heat dissipation and componen...

Страница 20: ...JDIMMF0 JDIMMD0 JDIMMC0 JDIMMB0 JDIMMA0 JDIMMC0 JDIMMB0 JDIMMA0 JDIMML0 JDIMMK0 JDIMMJ0 JDIMML0 JDIMMK0 JDIMMJ0 JDIMMG0 JDIMMH0 JDIMMI0 JDIMMG0 JDIMMH0 JDIMMI0 SFF 8643 SFF 8643 PCIE5 PCIE4 PCIE3 PCI...

Страница 21: ...JDIMMD0 JDIMMH0 JDIMME0 JDIMMI0 JDIMMF0 CPU 1 CPU 1 CPU 0 CPU 0 4 DIMMs CPU1 CPU0 JDIMM_L0 JDIMM_C0 JDIMM_J0 JDIMM_A0 JDIMML0 JDIMMC0 JDIMMK0 JDIMMB0 JDIMMJ0 JDIMMA0 JDIMMG0 JDIMMD0 JDIMMH0 JDIMME0 JD...

Страница 22: ...CPU 0 CPU1 CPU0 JDIMM_L0 JDIMM_C0 JDIMM_K0 JDIMM_B0 JDIMM_J0 JDIMM_A0 JDIMM_G0 JDIMM_D0 JDIMM_I0 JDIMM_F0 10 DIMMs JDIMML0 JDIMMC0 JDIMMK0 JDIMMB0 JDIMMJ0 JDIMMA0 JDIMMG0 JDIMMD0 JDIMMH0 JDIMME0 JDIM...

Страница 23: ...he DIMM socket by pressing the retaining clips outward Step 2 Insert the memory module into the slot Make sure that the DIMM notch is accurately positioned Step 3 Close the retaining clips to complete...

Страница 24: ...1 Press the release button on both sides of the system Step 2 Pull horizontally away from the front panel and lift upward to remove 2 3 2 Installing the Top Cover Position the top cover onto the syste...

Страница 25: ...stalling the Motherboard Step 1 Push the motherboard into the system Step 2 Secure the screw x 8 pcs on both sides x 4 pcs on each side of the system This information is provided for professional tech...

Страница 26: ...1 Push the latch inward and hold the tray handle Step 2 Pull the tray handle to remove 2 5 2 Installing the Power Supply Unit Push the tray handle on the module to install This information is provided...

Страница 27: ...and Installing the Fan Module 2 6 1 Installing and removing the Fan Insert or pull the fan module to install or remove the the fan module Make certain to align the fan module to the appropriate slot T...

Страница 28: ...p 1 Remove the 4 screws from both sides of the system Step 2 Pull the motherboard tray from the rear of the chassis to reveal the bottom row of the fan Step 3 Remove the bottom row of the fan by pulli...

Страница 29: ...rd Disk Tray 2 7 1 2 Removing the 2 5 hard disk drive tray Step 1 Press the release button on the HDD tray lever Step 2 Pull the HDD tray out of the system to remove 2 7 1 1 Installing the 2 5 hard di...

Страница 30: ...5 Hard Disk Tray 2 7 2 1 Installing the 3 5 hard disk drive tray Push the HDD tray lever and tray into the system 2 7 2 2 Removing the 3 5 hard disk drive tray Step 1 Press the release button on the H...

Страница 31: ...21 Chapter 2 Hardware Setup SB402 VG User Manual Rear Panel 3 5 Tray This information is provided for professional technicians only...

Страница 32: ...Disk Drive Directly place HDD into tool less HDD tray untli it snaps Please check if the screw holes on HDD match the dimples on HDD tray HDD can also be screwed on HDD tray by fastening two screws as...

Страница 33: ...Disk Drive Directly place HDD into tool less HDD tray untli it snaps Please check if the screw holes on HDD match the dimples on HDD tray HDD can also be screwed on HDD tray by fastening two screws as...

Страница 34: ...Step 2 Release the lock pin to remove the HDD backplane 2 8 2 Installing the HDD Backplane Step 1 Slide the HDD backplane module into the enclosure Step 2 Secure the HDD backplane module onto the enc...

Страница 35: ...tallation guide that came with your purchased product CAUTION They rack may tilt and fall due to incorrect installation or placed on uneven grounds The rack must be placed in a flat surface before you...

Страница 36: ...VG User Manual 2 Place the inner rail firmly against the side of the chassis Make sure that the hooks are straight and aligned with the holes in the inner rail 3 Slide the inner rail forward until it...

Страница 37: ...Hardware Setup SB402 VG User Manual 4 Press the locking tab and push the middle rail back into the outer rail 5 Hang the hooks of the rails on the rack holes and if necessary secure with screws 1 2 op...

Страница 38: ...ils as necessary 7 Pull the middle rail out of the front of the outer rail and make sure that the ball bearing shuttle is locked at the front of the middle rail Align the inner rails with the middle r...

Страница 39: ...n both sides of the chassis simultaneously and push the chassis all the way into the rear of the rack If additional security is required secure the chassis handles to the front of the rack with two sc...

Страница 40: ...SASPort x4 12Gb s PCI Express x 16 S25FL256SAGMFI001 NVSRAM CY14V101LA BA25 Flash UART0 Debug port ICE0 Debug port PCIe slot X8 PCI E GEN3 8GT s X8 Port1 IOU0 PCIE x 8 PCI E GEN3 8GT s SFF 8643 SFF 86...

Страница 41: ...N4 CN5 CN6 36 ME Force Recovery Mode Jumper J3 11 SFF 8643 Connector SAS CN7 CN8 37 BMC Debug Port Select Jumper J27 12 Battery Socket JBAT 38a 38b Front COM Header JCOM1 JCOM4 13a 13b Serial ATA SATA...

Страница 42: ...B2 B3 B5 A1 A2 A3 A4 A5 A6 A7 A8 A9 C8 C6 C2 C3 C5 C9 C7 C4 C1 D6 D8 D3 D2 D5 D9 D7 D4 D1 B1 B4 B7 B9 B8 B6 B2 B3 B5 A1 A2 A3 A4 A5 A6 A7 A8 A9 A9 A8 A7 A6 A5 A4 A3 A2 A1 B5 B3 B2 B6 B8 B9 B7 B4 B1 D...

Страница 43: ...RT Header J20 12V 12V 12V 12V GND GND GND GND PWM TACH 12V GND 3 3V GND PMBUS_ALERT_N SMB_PMBUS_DATA SMB_PMBUS_CLK GND 5V 5V 5V N C GND GND GND PS_ON GND 12V 3 3V 3 3V 12V 12V 5V_AUX POWER OK GND 5V G...

Страница 44: ..._EXP1_RX_DN_0 GND D6 B6 GND CPU1_EXP1_TX_DP_2 D7 B7 CPU1_EXP1_RX_DP_2 CPU1_EXP1_TX_DN_2 D8 B8 CPU1_EXP1_RX_DN_2 GND D9 B9 GND 10d SFF 8643 Connector for PCIe CN4 SMBDAT_MUX_4 C1 A1 CLK_100M_SSD4_P SMB...

Страница 45: ...EXP_TX_N5 D5 B5 SAS_EXP_RX_N5 GND D6 B6 GND SAS_EXP_TX_P4 D7 B7 SAS_EXP_RX_P4 SAS_EXP_TX_N4 D8 B8 SAS_EXP_RX_N4 GND D9 B9 GND 11b SFF 8643 connector for SAS CN8 SIO0_SAS_DOUT C1 A1 N C GND C2 A2 SIO0_...

Страница 46: ...L0 ICE0_TRST_L ICE0_TCK SAS3008_1V8 GND N C 5V_USB23 PCH_FP_USB3_RX_N2 PCH_FP_USB3_RX_P2 GND PCH_FP_USB3_TX_N2 PCH_FP_USB3_TX_P2 GND PCH_FP_USB2_N2 PCH_FP_USB2_P2 PCH_USB_OC 23 KEY no pin 5V_USB23 PCH...

Страница 47: ...GND PCH_PME_N PCH_LPC_CLKRUN_N PCH_SMI_N 5V_AUX 10 PCH_LPC_LAD0 3 3V PCH_LPC_LAD3 RST_PLTRST_N PCH_LFRAME_N CLK_24M_DP80 GND PCH_LPC_LAD1 PCH_LPC_LAD2 AST_SERIRQ PCH_LDRQ0_N GND 11 CPU0_HP_I2C_CLK CP...

Страница 48: ...51 Front VGA Header VGA_INT GND 3 3V_DUAL GND PCH_GPP_C10 SW_PWR_BTN SW_RST_BTN TXDC RXDC GND BMC_UART_TXD5 BMC_UART_RXD5 GND NC I2C1SCL GND I2C1SDA BMC_GPY0 BMC_GPY1 EXTRST I2C9SCL I2C9SDA GND GND I2...

Страница 49: ...verride Jumper J8 J8 Setting Short Flash Security override Open Normal Default 20 NTB Jumper JNTB JNTB Setting Short Downstream port Open Upstream port Default 22 System Power Good Lock JPG_LOCK JPG_L...

Страница 50: ...tical failure is detected Hard Disk Green Blinking Disk activity is detected Off No disk activity is detected NIC 1 Green Blinking NIC1 activity is detected Off NIC is not active NIC 2 Green Blinking...

Страница 51: ...9 10 11 12 13 14 15 16 17 18 19 20 21 22 1 13 1 20 19 2 1 20 19 2 1 20 19 2 A2 A1 B1 B2 A48 A49 B49 B48 A2 A1 B1 B2 A2 A1 B1 B2 A48 A49 B49 B48 C8 C6 C2 C3 C5 C9 C7 C4 C1 D6 D8 D3 D2 D5 D9 D7 D4 D1 B1...

Страница 52: ...40 SB402 VG User Manual Chapter 3 Hardware Settings 3 6 HDD Backplane 2 Bay 3 6 1 Placement Top view Bottom view...

Страница 53: ...BP Power JPWR Activity Selection HD_ACT_SW0 HD_ACT_SW1 Open Standard 1 On And 5Hz on DAS for SSD320 2 On Invert DAS for SSD520 LED I O Header JLED_E HDD1 HDD0 HDD0 SATA0 Power Header SATA1 1 4 5V GND...

Страница 54: ...Chapter 3 Hardware Settings 3 6 4 LED Indicator SATA HD Link Status LED0 LED1 Blue On Link up Blue Blinking Activity detected Blue Off Link down Red On HDD error external control only Red Off HDD Nor...

Страница 55: ...43 Chapter 3 Hardware Settings SB402 VG User Manual 3 7 HDD Backplane 12 Bay 3 7 1 Placement Top view Bottom view...

Страница 56: ...Connector Location Top view Bottom view HDD11 HDD12 HDD10 HDD7 HDD8 HDD9 HDD4 HDD5 HDD6 HDD3 HDD2 HDD1 JPWR1 JPWR2 JFAN1 JFAN2 JFAN3 JFAN4 JPMBUS JEXP_UART JEXP2 SASHD3 SASHD2 SASHD1 JMCU_DBG JMCU_UA...

Страница 57: ...JPWR1 Pin Description Pin Description 7 12V 1 GND 8 12V 2 GND 9 3 3V 3 GND 10 5V 4 MUTE_L 11 5VSTBY 5 PSU_N1 12 PS_ON_L 6 GND Power Connector JPWR2 Pin Description Pin Description 8 12V 1 GND 9 12V 2...

Страница 58: ...C_CLOCK 3 I2C_DATA 4 N A FAN Connector JFAN1 JFAN2 JFAN3 JFAN4 Pin Description 1 GND 2 12V 3 TACH 4 PWM Console for Expander JEXP_UART Pin Description Pin Description 2 DEBUG_RXD 1 SMART_RXD 4 GND 3 G...

Страница 59: ...47 Chapter 3 Hardware Settings SB402 VG User Manual 3 7 4 LED Indicator Act Fail Act Fail Act Fail Act Fail SASHD Status LED LED1 LED2 LED5...

Страница 60: ...7 DEVICE OFF Red Blinking Set by any of the following bits 1 RQST CONS CHECK 2 RQST IN CRIT ARRAY 3 RQST IN FAILED ARRAY 4 RQST REBUILD REMAP 5 RQST R R ABORT 6 RQST INSERT 7 RQST REMOVE 8 PRDFAIL Red...

Страница 61: ...loader mode 2 54mm Header for Front I O JFRONT Fan number select Pin 5 6 Pin 3 4 Pin 1 2 Fan no support Active Fan Locate Close Close Close No Fan Close Close Open One Fan JFAN1 Close Open Close Two...

Страница 62: ...50 SB402 VG User Manual Chapter 3 Hardware Settings AT Mode Setting Pin Description Remark 9 GND 10 AT_SEL_N Active Low Mute SW Pin Description Remark 17 GND 18 MUTE Input Active Low...

Страница 63: ...51 Chapter 3 Hardware Settings SB402 VG User Manual 3 7 6 Drive Slot Map...

Страница 64: ...52 SB402 VG User Manual Chapter 3 Hardware Settings 3 8 1 Placement Top view Bottom view 3 8 HDD Backplane 24 Bay...

Страница 65: ...HDD6 HDD12 HDD13 HDD19 HDD24 HDD23 HDD22 HDD21 HDD20 HDD18 HDD16 HDD17 HDD15 HDD14 HDD7 HDD8 HDD9 HDD10 HDD11 HDD1 HDD2 HDD3 HDD4 HDD5 JPWR1 JPWR2 JFAN1 JFAN2 JFAN4 JFAN3 JPMBUS JEXP_UART JEXP2 SASHD...

Страница 66: ...JPWR1 Pin Description Pin Description 7 12V 1 GND 8 12V 2 GND 9 3 3V 3 GND 10 5V 4 MUTE_L 11 5VSTBY 5 PSU_N1 12 PS_ON_L 6 GND Power Connector JPWR2 Pin Description Pin Description 8 12V 1 GND 9 12V 2...

Страница 67: ...C_CLOCK 3 I2C_DATA 4 N A FAN Connector JFAN1 JFAN2 JFAN3 JFAN4 Pin Description 1 GND 2 12V 3 TACH 4 PWM Console for Expander JEXP_UART Pin Description Pin Description 2 DEBUG_RXD 1 SMART_RXD 4 GND 3 G...

Страница 68: ...56 SB402 VG User Manual Chapter 3 Hardware Settings 3 8 4 LED Indicator LED3 LED3 SASHD Status LED SASHD Status LED LED2 LED2 LED1 LED1...

Страница 69: ...7 DEVICE OFF Red Blinking Set by any of the following bits 1 RQST CONS CHECK 2 RQST IN CRIT ARRAY 3 RQST IN FAILED ARRAY 4 RQST REBUILD REMAP 5 RQST R R ABORT 6 RQST INSERT 7 RQST REMOVE 8 PRDFAIL Re...

Страница 70: ...mm Header for Front I O JFRONT Fan number select Pin 5 6 Pin 3 4 Pin 1 2 Fan no support Active Fan Locate Close Close Close No Fan Close Close Open One Fan JFAN1 Close Open Close Two Fan JFAN1 and JFA...

Страница 71: ...59 Chapter 3 Hardware Settings SB402 VG User Manual AT Mode Setting Pin Description Remark 9 GND 10 AT_SEL_N Active Low Mute SW Pin Description Remark 17 GND 18 MUTE Input Active Low...

Страница 72: ...60 SB402 VG User Manual Chapter 3 Hardware Settings 3 8 6 Drive Slot Map...

Страница 73: ...tem off and on NOTE The following pages provide the details of BIOS menu Please be noticed that the BIOS menu are continually changing due to the BIOS updating The BIOS menu provided are the most upda...

Страница 74: ...system information and date time Advanced Allows configuration of advanced system settings Security Sets passwords and security functions Power Sets the power management parameters Boot Sets boot opt...

Страница 75: ...ettings SB402 VG User Manual Step 2 There will be a message Entering SETUP displayed on the diagnostics screen Step 3 Identify the BIOS version NOTE For the official released version the last digit of...

Страница 76: ...64 SB402 VG User Manual Chapter 4 BIOS Configuration Settings Step 4 Load Optimal Default Setting Step 5 Save the setting and exit the BIOS setup utility...

Страница 77: ...65 Chapter 4 BIOS Configuration Settings SB402 VG User Manual 4 2 3 Update To identify the latest BIOS version please check the BIOS setup...

Страница 78: ...to update Flash in the DOS environment please use H2OFFT D utility To use this utility you must include the flash bat H2OFFT D exe and bin file in the same folder Please follow the instructions to upd...

Страница 79: ...67 Chapter 4 BIOS Configuration Settings SB402 VG User Manual Main Option Key 4 3 1 Main Option Key Description System time Configures the current time System date Configures the current date 4 3 Main...

Страница 80: ...PCIe ARI Enable Disable ARI Forward Enable Disable Spread Spectrum Enable Disable Redfish On Off Enable Disable 4 4 2 Video Configuration Video Configuration Display Mode Plug In First On Board First...

Страница 81: ...ncy Select 9 6Gb s 10 4Gb s Auto Use Per Link Setting Link L0p Enable Auto Enable Disable Link L1 Enable Auto Enable Disable Legacy VGA Socket Min 0 Max 3 Legacy VGA Stack Min 0 Max 6 Memory Configura...

Страница 82: ...able PCIe ACPI Hot Plug Enable Disable Per Port MC BaseAddress Range Auto Below 4G MC Index Position 12 20 MC Num Group 1 8 32 64 PCI E Completion Timeout Global Disable No Yes Per Port PCI E Global T...

Страница 83: ...are PM State Control Hardware P States Disable Native Mode Out of Band Mode Native Mode with No Legacy Support HardwarePM Interrupt Enable Disable EPP Enable Enable Disable EPP profile Performance Bal...

Страница 84: ...t Plug Enable Disable Configure as eSATA Enable Disable Mechanical Presence Switch Enable Disable Spin Up Device Enable Disable SATA Device Type Hard Disk Drive Sata State Drive SATA Topology Unknown...

Страница 85: ...eSATA Enable Disable Spin Up Device Enable Disable sSATA Device Type Hard Disk Drive Sata State Drive SATA Topology Unknown ISATA Direct Connect Flex M 2 Port 1 Enable Disable Hot Plug Enable Disable...

Страница 86: ...ec 1s 3 5s Disable MPL for Uplink x16 MPL for Uplink x8 MPL 128B MPL 256B MPL 512B PCIE Clock Gating Enable Disable PCH DMI ASPM Platform POR ASPM L Disable DMI Link Extended Synch Control Enable Disa...

Страница 87: ...Error Reporting Enable Disable PCIe Speed Auto Gen 1 Gen 2 Gen 3 MSI Enable Disable PCIE Lane Topology Unknown x1 x4 Sata Express M 2 Max Payload Size MPL MPL 128B MPL 256B Compl Timeout 40 50ms spec...

Страница 88: ...Max 240 ACPI SPMI Table Enable Disable Boot Option Support Enable Disable Set BIOS version to BMC Enable Disable BMC Configuration Watchdog Timer Support Enable Disable Not disable in OS Enable Disabl...

Страница 89: ...Rate 1200 2400 4800 9600 19200 38400 57600 115200 Data Bits 7 Bits 8 Bits Parity None Even Odd Stop Bits 1 Bits 2 Bits Flow Control None RTS CTS XON XOFF Information Wait Time 0 Second 2 Seconds 5 Se...

Страница 90: ...on Settings Security Option Key 4 5 1 Security Security Current TPM Device Not Detected TPM 1 2 TPM 2 0 TrEE Protocol Version 1 0 1 1 TPM Availability Available Hidden TPM Operation No operation Disab...

Страница 91: ...79 SB402 VG User Manual Chapter 5 BMC Configuration Settings Power Option Key 4 6 1 Power Power Wake on PME Enable Disable 4 6 Power...

Страница 92: ...uiet Boot Enable Disable Network Stack Enable Disable PXE Boot to LAN Enable Disable PXE Boot capability Disable UEFI IPv4 UEFI IPv6 UEFI IPv4 UEFI IPv6 Legacy Add Boot Options First Last Auto ACPI Se...

Страница 93: ...your changes without exiting the system Exit Discarding Changes Discard your changes when existing the system Load Optimal Defaults Load optimal default items Load Custom Defaults Resets the BIOS sett...

Страница 94: ...There are two methods to setup BMC IP 5 1 Method 1 Use the BIOS Setup Step 1 BIOS SETUP Advanced H2O IPMI configuration BMC Configuration IPv4 source Static Chapter 5 BMC Configuration Settings Chapte...

Страница 95: ...83 SB402 VG User Manual Chapter 5 BMC Configuration Settings Step 2 Input the IP address Set static IP...

Страница 96: ...84 Chapter 5 BMC Configuration Settings SB402 VG User Manual Step 3 Input the subnet mask address...

Страница 97: ...e default BMC IP address 192 168 22 22 Step 2 Use the default user name and password for first time login to BMC WEB GUI Field Default User Name admin Password admin NOTE The default user name and pas...

Страница 98: ...hboard The Dashboard page gives the overall information about the status of a device Server Health Sensor Readings Then Sensors Readings page displays all the sensor related information Settings The S...

Страница 99: ...the setting for mouse emulation from local window to remote screen For Windows OS environment set mode to absolute For Linux OS environment set mode to relative For SLES 11 OS environment set mode to...

Страница 100: ...88 Chapter 5 BMC Configuration Settings SB402 VG User Manual Environmental setting...

Страница 101: ...aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Em...