background image

UM_SB101-UR_v1_010719

SB101-UR

Storage Server Barebone

User's Manual

Содержание SB101-UR

Страница 1: ...UM_SB101 UR_v1_010719 SB101 UR Storage Server Barebone User s Manual...

Страница 2: ...lling the Power Supply Unit Module 12 2 4 1 Removing the Power Supply Unit 12 2 4 2 Installing the Power Supply Unit 12 2 5 Removing and Installing the Fan Module 13 2 5 1 Removing the Fan 13 2 5 2 In...

Страница 3: ...1 Main 42 4 4 Advanced 43 4 4 1 iSCSI Configuration 43 4 4 2 Trusted Computing 43 4 4 3 Serial Port Console Redirection 44 4 4 4 PCI Subsystem Settings 44 4 4 5 Network Stack Configuration 44 4 4 6 M...

Страница 4: ...53 4 10 Save and Exit 54 4 10 1 Save and Exit 54 4 11 Update Requirement 55 4 11 1 Utility 55 4 11 2 Update under EFI Shell 55 4 11 3 Update under Linux 55 4 11 4 Update under Windows 55 Chapter 5 BMC...

Страница 5: ...Copyright 2019 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 6: ...G Chapter 1 Product Features SB101 UR User Manual Document Release History Release Date Version Update Content January 2019 1 User s Manual release to public...

Страница 7: ...t is essential that only the supplied power cord be used 2 Use only shielded cables to connect I O devices to this equipment 3 You are cautioned that changes or modifications not expressly approved by...

Страница 8: ...n a stable surface when install A drop or fall could cause injury Please keep this equipment away from humidity Carefully mount the equipment into the rack in such manner that it won t be hazardous du...

Страница 9: ...power cord or plug is damaged 2 Liquid has penetrated the equipment 3 The equipment has been exposed to moisture 4 The equipment does not work well or will not work according to its user manual 5 The...

Страница 10: ...ngs This chapter elaborates the overall layout of the server motherboard including multifarious connectors jumpers and LED descriptions These descriptions assist users to configure different settings...

Страница 11: ...If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify that the numbe...

Страница 12: ...troller Intelligent Platform Interface 2 0 IPMI 2 0 iKVM Media Redirection IPMI over LAN Serial over LAN SMASH Support Network Controllers Intel PCH Lewisburg Integrated 10GbE LAN Controller with dual...

Страница 13: ...greater band width and utilization In addition to the noteworthy features of the barebone SB101 UR provides immediate and efficient management with Onboard Baseboard Management Controller and greater...

Страница 14: ...nel 4x 3 5 HDD tray System button and LED indicator Rear Panel 550 W 1 1 redundant PSU optional 800 W PSU BTO System Reset Switch System UID Switch System UID LED System Power Switch System Power LED...

Страница 15: ...5 Chapter 1 Product Features SB101 UR User Manual Major Components 550W 1 1 redundant power supply unit or 800 W BTO 6 x 4028mm system fans...

Страница 16: ...re vulerable and easily susceptible to damage if fingers or any foreign objects are pressed against them Please keep the socket protective cover on when the processor is not installed WARNING When unp...

Страница 17: ...the heatsink on top of the CPU Step 2 Secure the screws on the heatsink Removal Step 1 Dislodge the screws x 4 on the heatsink Step 2 Remove the heatsink by lifting it upward NOTE Failure to tighten...

Страница 18: ...ion Step 1 Unlock the DIMM socket by pressing the retaining clips outward Step 2 Insert the memory module into the slot Make sure that the DIMM notch is accurately positioned Step 3 Close the retainin...

Страница 19: ...DIMM N with EEC Error Correction Code Verify if all of the DIMMs installed are of the same DIMM type to avoid memory failure and loss of performance speed CPU0 CPU1 DIMM C0 DIMM C1 DIMM B0 DIMM B1 DIM...

Страница 20: ...n Order Populate the DIMM slots according to the suggested order below to ensure a stable system performance CPUs DIMM Slots Connectors CPU0 CPU1 Slots A0 A1 B0 B1 C0 C1 D0 D1 E0 E1 F0 F1 A0 A1 B0 B1...

Страница 21: ...11 Chapter 2 Hardware Setup SB101 UR User Manual Step 1 Press the release button x 2 on the top cover Step 2 Remove the top cover 2 3 Removing and Installing the Top Cover...

Страница 22: ...p 1 Press the latch and hold the tray on the module Step 2 Pull the module out of the system barebone 2 4 2 Installing the Power Supply Unit Push the module into the system until it clicks Check if th...

Страница 23: ...the fan from the fan slot 2 5 2 Installing the Fan Step 1 Insert the fan module into the fan slot Step 2 Install the fan connector NOTE The heatsink s fan should be blowing toward the rear end of the...

Страница 24: ...s the release button the tray lever The lever will be ejected from the tray Step 2 Pull the tray lever outward to remove the tray 2 6 2 Installing the Hard Disk Drive Insert the hard disk drive into t...

Страница 25: ...ust the hook on the side of the backplane to detach it from the system Step 3 Dislodge the screws on the backplane module x 3pcs 2 7 2 Installing the HDD Backplane Step 1 Slide the HDD backplane modul...

Страница 26: ...w Step 2 Remove the riser card from the system 2 8 2 Installing the Riser Card Step 1 Align and insert the riser card with bracket into the riser card slot Check if the card is properly aligned Step 2...

Страница 27: ...17 Chapter 2 Hardware Setup SB101 UR User Manual Locate the positon of airduck as demonstrated below Make sure to position it on top of the fan modules 2 9 Removing and Installing the Airduck...

Страница 28: ...18 Chapter 2 Hardware Setup SB101 UR User Manual 1 Release and detach the inner rail from the slide 2 10 Tool less Slide Blade Installation PUSH 1 2 3 4...

Страница 29: ...19 Chapter 2 Hardware Setup SB101 UR User Manual 2 Attach the inner rail to the barebone Click 1 2...

Страница 30: ...20 Chapter 2 Hardware Setup SB101 UR User Manual 3 Attach the outer rail to the rack Click Click PUSH 1 1 1 2...

Страница 31: ...21 Chapter 2 Hardware Setup SB101 UR User Manual 4 Pull out the middle channel until the ball bearing retainer is locked forward CAUTION Verify ball bearing retainer is locked forward 1 1 1 2...

Страница 32: ...ser Manual 5 Slide the release tab and push barebone into rack Make sure the barebone is completely installed onto the rack NOTE Tool less rails vary per order The rail in this manaul may not exactly...

Страница 33: ...the jumpers internal connectors and internal LEDs settings in SB101 UR 3 1 Motherboard Layout Chapter 3 Hardware Settings CPU0 CPU1 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 30 31 32 33 34...

Страница 34: ...r 0 CPU0 12 PCI E X16 Gen3 Slot2 J59 38 Fan Connector 2 J99 13 PCI E X16 Gen3 Slot1 J58 39 Fan Connector 1 J98 14 NIC OCP 2 0 Connector B J75 40 DIMM Slots for Processor 0 J11 J12 J9 J10 J7 J8 15 PCI...

Страница 35: ...A22 PS1 ALERT N B22 PS CR BUS R A23 PS1 VSENSE DN B23 PS LOAD SHARE A24 PS1 VSENSE DP B24 PS1 Present N A25 PS1 DCOK B25 PS1 ACOK 23 Power Supply Connectors J85 Pin Description Pin Description A1 Grou...

Страница 36: ...5 Pin Description Pin Description 1 Ground 9 12V 2 Ground 10 12V 3 Ground 11 12V 4 Ground 12 12V 5 Ground 13 12V 6 Ground 14 12V 7 Ground 15 RST_I2C_HDDBP_N 8 I2C_HDDBP_SDA 16 I2C_HDDBP_SCL 20 Rear 2H...

Страница 37: ...4_ ESD_DN 19 PSV_USB3_FRONT2 3 PCH_USB3_RX_P4_ ESD_DP 18 PCH_USB3_RX_P5_ ESD_DN 4 Ground 17 PCH_USB3_RX_P5_ ESD_DP 5 PCH_USB3_TX_P4_ ESD_DN 16 Ground 6 PCH_USB3_TX_P4_ ESD_DP 15 PCH_USB3_TX_P5_ ESD_DN...

Страница 38: ...0 2 TPM_Vendor_ID1 3 TPM_PRSNT_N 4 LPC_AD_1 5 LPC_FRAME_TPM_Module_N 6 LPC_SERIRQ 7 Ground 8 3V3 9 Clock_33M_PCH_LPC_TPM5 10 RST_LPC_TPM_Module_N 11 Ground 12 LPC_TPM_Module_AD 2 13 3V3_STBY 14 Groun...

Страница 39: ..._C_DN B6 PCH_SATA_TX_P1_C_DN A7 Ground B7 Ground A8 SGPIO_SATA_DATA0 B8 SGPIO_SATA_CLOCK A9 TP_SATA0_RSVD_A9 B9 SGPIO_SATA_LOAD A10 Ground B10 Ground A11 TP_SATA0_RSVD_A11 B11 TP_SATA0_RSVD_B11 A12 TP...

Страница 40: ...Ground A17 PCH_SATA_RX_P7_C_DP B17 PCH_SATA_TX_P7_C_DP A18 PCH_SATA_RX_P7_C_DN B18 PCH_SATA_TX_P7_C_DN A19 Ground B19 Ground 16 Slimline Connector 2 J70 Pin Description Pin Description A1 Ground B1 Gr...

Страница 41: ...X_S5_C_DN 2 PCH_SATA_TX_S5_C_DP 6 PCH_SATA_RX_S5_C_DP 3 PCH_SATA_TX_S5_C_DN 7 5V_SATADOM_2 4 Ground 8 5V 9 Ground 49 SATA SATADOM Connectors sSATA 4 J74 Pin Description Pin Description 1 Ground 5 PCH_...

Страница 42: ...tion Pin Description 1 Ground 4 BMC_FAN_PWM_2_R 2 PU_FAN_ID_2 5 PU_FAN_INSTALL_2_N 3 BMC_FAIL_2_R 6 12V 36 Fan Connectors 3 J100 Pin Description Pin Description 1 Ground 4 BMC_FAN_PWM_3_R 2 PU_FAN_ID_...

Страница 43: ...2 PU_FAN_ID_5 5 PU_FAN_INSTALL_5_N 3 BMC_FAIL_5_R 6 12V 30 Fan Connectors 6 J103 Pin Description Pin Description 1 Ground 4 BMC_FAN_PWM_6_R 2 PU_FAN_ID_6 5 PU_FAN_INSTALL_6_N 3 BMC_FAIL_6_R 6 12V 34 F...

Страница 44: ...tion 1 Ground 2 PU_VROC_CONN_PIN2 3 Ground 4 FM_PCH_SATA_RAID_KEY_R 2 Internal Serial Header J2043 Pin Description Pin Description 1 COM1_RES_DCD 2 COM1_RES_RX_N 3 COM1_RES_TX_N 4 COM1_RES_DTR 5 Groun...

Страница 45: ...LD2SSIFP_R_N 7 3V_FP 8 LED_HLTH_GRN_CPLD2SSIFP_R 9 DC_LED_HDD_ACT_CPLD2SSIFP_R_N 10 LED_HLTH_RED_CPLD2SSIFP_R 11 BTN_PWRON_SSIFP2CPLD_N 12 3V_Standby_FP 13 Ground 14 LED_NIC0_LINK_ACT_R_N 15 BTN_RST_S...

Страница 46: ...Recovery 11 Password Clear Jumper Setting J39 Function Password clear 6 BIOS CMOS Clear Jumper Setting J46 Function BIOS CMOS Clear Jumper Function 9 Manufacturing Mode Jumper Setting J90 Function Ma...

Страница 47: ...37 Chapter 3 Hardware Settings SB101 UR User Manual 3 4 HDD Backplane 3 4 1 Layout Top view Bottom view...

Страница 48: ...nction and Setting Pin Status Description 1 2 Open Disable External LED input Close Enable External LED input 3 4 Open ActivityLED from HDD Pin P11 Close ActivityLED from SGPIO 5 6 Open Identify behav...

Страница 49: ...vity LEDs Blue On HDD Present Blue Blinking HDD activity detected or has located HDD Off HDD has no connection or the power is off H D D Fa u l t S t a t u s LEDs Red On HDD has fault or located HDD R...

Страница 50: ...re listed below Function Key Description Select item Enter Select and enter sub screen Modify selected option F1 General help F2 Previous Value F3 Optimized defaults F4 Save Exit F5 F6 Change values F...

Страница 51: ...as PCH miscellaneous and server ME configuration Socket Configuration Allows configuration of socket settings such as processor Common RefCode UPI and memory configurtaion BMC Allows configuration of...

Страница 52: ...42 SB101 UR User Manual Chapter 4 BIOS Configuration Settings 4 3 1 Main Main Option Key Option Key Description System time Configures current time System date Configures current date 4 3 Main...

Страница 53: ...nced Option Key 4 4 1 iSCSI Configuration iSCSI Configuration Add an Attempt Delete Attempts Change Attempt Order 4 4 2 Trusted Computing Trusted Computing Security Device Support Enable Disable TPM S...

Страница 54: ...iguration Network Stack Enable Disable Ipv4 PXE Support Enable Disable Ipv4 HTTP Support Enable Disable Ipv6 PXE Support Enable Disable Ipv6 HTTP Support Enable Disable PXE boot wait time 0 1 2 3 4 5...

Страница 55: ...210ms 260ms to 900ms 1s to 3 5s 4s to 13s 17s to 64s No PCIe port active EC0 PCU Squelch exit ignore option Reset the SQ FLOP by CSR option 4 4 9 IIO1 Configuration IIO1 Configuration IOU2 IIO PCIe P...

Страница 56: ...d I O VT d Intel VT for Directed I O VT d Enable Disable Interrupt Remapping Enable Disable Pass Through DMA Enable Disable ATS Enable Disable Coherency Support Non Isoch Enable Disable Coherency Supp...

Страница 57: ...On board device PCIE Device RTC Wake system from S4 S5 Enable Disable 4 5 3 Server ME Configuration Server ME Configuration General ME Configuration Configures Server ME Technology Parameters Oper Fi...

Страница 58: ...rocessor Configuration Hyper Threading Enable Disable Enable Intel R TXT Enable Disable VMX Enable Disable Enable SMX Enable Disable Extended APIC Enable Disable Force x2APIC IDs Enable Disable AES NI...

Страница 59: ...1T MMIO High Granularity Size 1G 4G 16G 64G 256G 1024G Numa Enable Disable 4 6 5 Memory Configuratiuon Memory Configuration Memory Frequency Auto 1866 2133 2400 2666 Enable ADR Enable Disable Erase A...

Страница 60: ...2 Timer FB 2 Timer Enable Disable 4 7 2 FB 2 Timer Policy FB 2 Timer Do Nothing Reset Power Down Power Cycle 4 7 3 BMC Network Configuration BMC Network Configuration Configuration Address source Unsp...

Страница 61: ...administrator password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Creat...

Страница 62: ...Attempt Secure Boot Enable Disable Secure Boot Mode Standard Custom Key Management Provision Factory Default keys Install Factory Default Keys Enroll Efi Image Save All Secure Boot Variables Platform...

Страница 63: ...apter 4 BIOS Configuration Settings SB101 UR User Manual Boot Option Key 4 9 1 Boot Boot Bootup NumLock State On Off Quiet Boot Enable Disable New Boot Option Policy Default Place First Place Last 4 9...

Страница 64: ...tem after saving the changes Discard Changes and Reset Resets system setup without saving any changes Save Changes Saves the changes Discard Changes Discards the changes Restore Defaults Restores or l...

Страница 65: ...ux AMI Flash Utility 1 Copy AfuLnx_64 and RomFileName BIN to Linux OS 2 Open the folder with terminal 3 Enter AfuLnx_64 RomFileName BIN P B 4 Restart the system after finishing BIOS part flashing If y...

Страница 66: ...P setting The IP address is configurable Step 1 Open the browser then type in the default BMC IP address 192 168 22 108 Step 2 Use the default user name and password for first time BMC WEB GUI login F...

Страница 67: ...are allowed except for the configuration commands that can change the behavior of the out of hand interfaces Administrator All BMC commands are allowed No access Login access denied Notification Click...

Страница 68: ...supports BMC Watchdog Timer Commands 5 2 3 System LED Indicator System LED System Health Front Panel Green On Control By CPLD System is Good No Error Off Normally in Standby Amber Blink 1Hz Non Critic...

Страница 69: ...on ready approximate 120 sec then send the Set SEL Time command with the current system time to sync RTC timer In runtime on every BMC reset BMC will assert GPIO to generate SMI to BIOS then BIOS woul...

Страница 70: ...ype SSOL Authentications Administrator Administrator access over SOL Non Volatile Bit Rate 115200 115200 baud rate Volatile Bit Rate 115200 115200 baud rate Gratuitous ARP Interval 4 seconds ARP respo...

Страница 71: ...X Integrity None O O O O X HMAC SHA1 96 O O O O X HMAC MD5 128 O O X X X MD5 128 X X X X X HMAC SHA2 128 X X X X X Confidentiality None O O O O X AES CBC 128 O O O O X XRC4 128 X X X X X XRC4 40 X X X...

Страница 72: ...00x600 60 Yes Yes 1024x768 60 Yes Yes 1280x800 60 Yes Yes 1280x1024 60 Yes Yes 1440x900 60 Yes Yes 1600x1200 60 Yes Yes 1680x1050 60 Yes Yes 1920x1080 60 Yes Yes 1920x1200 60 Yes Yes Full Screen and W...

Страница 73: ...01 UR User Manual Chapter 5 BMC Configuration Settings Step 4 Select Remote Control from the menu bar The KVM window will pop up Step 5 Click the button Start KVM To terminate the KVM service click St...

Страница 74: ...ting it If the boot loader detects that the loaded firmware image is invalid it will not be executed BMC will select another SD storage for boot If Both of ROMs part are fail BMC SOC will reboot by WD...

Страница 75: ...aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Em...

Отзывы: