36
Chapter 3. 2U30 JBOD Subsystem Configuration Settings
Rack Venus User Manual
3�5�9 How to power off/on all disk drives automatically
This feature is applicable for SAS/SATA drives. If there is no connection with any
active SAS initiator by checking all wide ports, AIC Expander Controller powers
off all attached SAS/SATA drives to save power consumption. Otherwise, AIC
Expander Controller powers on all attached SAS/SATA drives to provide drive
access service to any active SAS initiator. The same setting should be applied to
HUB and EDGE.
(A) Apply the following commands on the COM port.
cmd> check_wide_port standby
cmd> reset