Страница 1: ...UM_Lepus_v2 2_112618 Lepus Server Motherboard User s Manual...
Страница 2: ...4 2 1 3 CPU Heatsink Installation 7 2 2 System Memory Setup 8 2 2 1 DIMM Installation 8 2 2 2 DIMM Location 9 2 2 3 Dimm Slot Installation Order 9 Chapter 3 Motherboard Settings 10 3 1 Block Diagram 1...
Страница 3: ...Bridge Configuration 24 4 5 3 South Bridge Configuration 25 4 6 Security 26 4 6 1 Security 26 4 7 Server Management 27 4 7 1 FRB 2 Timer 27 4 7 2 OS Watchdog Timer 27 4 7 3 System Event Log 28 4 7 4...
Страница 4: ...5 2 9 Remote Control 39 5 2 10 Power Control 44 5 2 11 Chassis Identify Control 45 5 2 12 Set Front Panel Enables 45 5 2 13 Maintenance 46 5 2 14 Sign out 48 Chapter 6 Technical Support 49 Contents...
Страница 5: ...ease Date Version Update Content April 2018 1 User s Manual release to public September 2018 2 1 New cover 2 Correct grammar error 3 Connector and jumper update Novemer 2018 2 2 1 Motherboard settings...
Страница 6: ...Copyright 2018 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...
Страница 7: ...is essential that only the supplied power cord be used 2 Use only shielded cables to connect I O devices to this equipment 3 You are cautioned that changes or modifications not expressly approved by t...
Страница 8: ...cleaning Do not use liquid cleaners or aerosol cleaners Do not use this product near a water source including faucet and lavatory Never spill liquids of any kind on this product Never shove objects o...
Страница 9: ...fragile and vulnerable to exterior influence Do not attempt to endanger the device by placing the device in a potentially unstable or hazardous surroundings including positioning the device on an une...
Страница 10: ...pter 1 Product Features This section describes the hardware specifications and features of the Lepus motherboard The fundamental components of the Lepus severboard are provided below 1 1 Components Le...
Страница 11: ...l Broadcom LSI SAS 3008 IOC On board Devices IPMI Aspeed AST2400 Advanced PCIe Graphics Remote Management Processor Serial over LAN Network for quad port GbE BTO management port Graphics Aspeed AST240...
Страница 12: ...ormance providing support with two channels of DDR4 2400 2133 Unbuffered ECC UDIMM Up to 4x1GBase T and optional Broadcom LSI SAS 3008 IOC onboard Lepus series server board enables next generation ser...
Страница 13: ...at provides support for more than two CPU types and a Thermal Design Power TDP of up to 80W on selected models CAUTION When unpacking a processor hold the processor only by the edge to avoid touching...
Страница 14: ...he CPU socket Do not throw away the protective cover It may be further used for RMA purposes Step 4 Orient the processor with the socket so that the processor cutouts match the four orientation posts...
Страница 15: ...ual Step 5 Close the loading plate by pushing down the locking lever on the side Slide the tip of the lever under the notch on the loading plate Make sure the loading plate tab engages under the socke...
Страница 16: ...ase onto the heatsink and position the heatsink onto the CPU socket Make certain that the heatsink is accurately positioned Step 2 Tighten the four screws in a diagonal sequence Secure the screws a co...
Страница 17: ...annel per CPU 2 2 1 DIMM Installation Step 1 Unlock the dimm socket by pressing the retaining clips outward Step 2 Insert the memory module into the slot Make sure that the DIMM notch is accurately po...
Страница 18: ...t Installation Order Populate the DIMM slots in the following order JDIMMB1 JDIMMB0 JDIMMA1 JDIMMA0 CPU1 JDIMM_A0 JDIMM_B0 CPU0 DIMM NUMBER DIMM ARRANGEMENT 2 DIMMs JDIMM_A0 JDIMM_B0 JDIMM_A1 JDIMM_B1...
Страница 19: ...Jack RJ45 Jack RJ45 Jack USB3 0 USB3 0 USB3 0 USB3 0 USB3 0 USB3 0 USB2 0 PCI Express x16 Slot PCI Express x8 PTN3355 Display Port to VGA LSISAS3008 12Gb s SAS SATA Controller 0 ohn Resistor BOM optio...
Страница 20: ...Address 0xA4 J8C3 27 SAS Port LSI SAS3008 MINI SAS 2 Port 12 Gbit s OPTIONAL WITH BTO J29 9 DIMM_A1 DDR4 Black Address 0xA2 J8C2 28 SAS Port LSI SAS3008 MINI SAS 2 Port 12 Gbit s OPTIONAL WITH BTO J28...
Страница 21: ...en LED1 48 USB Port USB 3 0 2 J5 41 LSI SAS3008 Error LED Red LED4 49 VGA Port D Sub COM Port RS 232 J10 42 PCI Express Slot x8 Slot w x8 link OPTIONAL WITH BTO J11 50 8 Pin CPU Power Supply Connector...
Страница 22: ...apter 3 Motherboard Settings Lepus User Manual 3 3 Layout 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 51 5...
Страница 23: ...CC3 5 1 VCC3_AUX GND BMC_SMB_DATA 1 4 FP_PWR_BTN_N GND 4 3 FP_PWR_BTN_N GND 2 1 FP_RST_BTN_N GND 4 3 FP_RST_BTN_N GND 2 1 7 GND SATA TX DP SATA TX DN GND SATA RX DN SATA RX DP GND 1 2 1 10 9 SMBCLK SM...
Страница 24: ...ACH7 TACH8 TACH9 TACH10 SMBDATA SMBCLK NC LSIRQ0 LAD3 LAD2 LAD1 LAD0 VCC3 NC GND CLK GND RESET KEY FRAME 2 1 16 15 1 2 9 10 DCD RXD TXD DTR GND DSR RTS CTS RI 1 2 5 6 INTRUSION GND 2 1 PWRLED KEY PWRL...
Страница 25: ...utiility Turn on or reboot your system Press DEL or F2 during POST Del on remote console to start the BIOS setup 4 1 Navigation Keys The navigation keys are listed below Function Key Description Chang...
Страница 26: ...ings such as ACPI features boot and chipset configuration Security Sets passwords and security functions Boot Sets boot options such as Quick Boot or USB Boot Power Allows configuration of timer Syste...
Страница 27: ...18 Chapter 4 BIOS Configuration Settings Lepus User Manual Main Option Key 4 3 1 Main Main System time Configures current time System date Configures current date 4 3 Main Lepus...
Страница 28: ...1 Trusted Computing Displays Trusted Computing settings Trusted Computing Security Device Support Enable Disable 4 4 2 APCI Settings Displays system ACPI parameters ACPI Settings Security Device Supp...
Страница 29: ...ct Enable Disable NMI Function Enable Disable PMBUS Support Enable Disable Number of PSU 1 1 1 4 4 4 Hardware Health Configuration Displays Hardware Health Configuration parameters Hardware Health Con...
Страница 30: ...ings Serial Port Console Redirection Console Redirection Settings Serial Port Console Redirection Disable Enable Terminal Type VT100 VT100 VT UTF8 ANSI Bits per Second 38400 9600 19200 57600 115200 Da...
Страница 31: ...Configuration Hyper threading Enable Disable Active Processor Cores All One Intel Virtualization Technology Enable Disable Boot Performance Mode Turbo Performance Max Non Turbo Performance Max Batter...
Страница 32: ...rap Response Immediate Postponed Boot option filter UEFI and Legacy Legacy Only UEFI Only Network Legacy Do not launch UEFI Storage Legacy Do not launch UEFI Video Legacy Do not launch UEFI Other PCI...
Страница 33: ...arameters Intel Server Platform Services Configuration Intel Server Platform Services Enable Disable Power Measurement support Enable Disable Hardware change detected Enable Disable 4 5 2 North Bridge...
Страница 34: ...iguration Displays PCH Parameters South Bridge Configuration Intel PCH RC Version Read only Intel PCH SKU Name Read only Intel PCH Rev ID Read only DeepSx Power Policies Enable in S4 S5 Disable High P...
Страница 35: ...ministrator password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create...
Страница 36: ...es 4 minutes 5 minutes 6 minutes FRB 2 Timer Policy Do Nothing Reset Power Down Power Cycle 4 7 2 OS Watchdog Timer OS Watchdog Timer Helps determine whether the OS is successfully loaded or follows t...
Страница 37: ...ble Disable Erase SEL No Yes on next reset Yes on every reset When SEL is Full Do Nothing Erase Immediately Log EFI Status Codes Disable Both Error Code Progress Code 4 7 4 BMC Network Configuration B...
Страница 38: ...tem boot order Endless Boot Configures Endless boot Wait for ESC If Error Configures Wait ESC key Function When Chassis intrusion CMOS Clear or BMC not Response New Boot Option Policy Controls the pla...
Страница 39: ...m after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes don...
Страница 40: ...ting The IP address is configurable Step 1 Open the browser then type in the default BMC IP address 192 168 22 108 Step 2 Use the default user name and password for first time BMC WEB GUI login Field...
Страница 41: ...t and video Settings The Settings page allows you to configure various basic settings such as date time KMV Mouse Services and ect Remote Control The Remote Control page allows you to remotely manage...
Страница 42: ...ands are allowed except for the configuration commands that can change the behavior of the out of hand interfaces Administrator All BMC commands are allowed No access Login access denied Notification...
Страница 43: ...boord page displays device system and network information Click Dashboard on the menu bar to view the overall information of the server 5 2 4 Sensor The Sensor page displays the status and records on...
Страница 44: ...on including Vendor name Model and Sofware version Click System Inventory on the menu bar to open 5 2 6 FRU Information The FRU Information page displays Basic Information Chassis Information Board In...
Страница 45: ...on Settings Lepus User Manual 5 2 7 Logs and Reports The System Inventory page displays IPMI Event Log and Video Log Click Logs and Reports from the menu bar select Event Log or Video Log to view the...
Страница 46: ...s page displays the configuration settings for Date Time External User Services KVM Mouse Setting Log Settings Media Redirection Settings Network Settings PAM Order Settings Platform Event Filter Serv...
Страница 47: ...ttings VMedia Instance Settings Remote Session Network Settings Network Settings Network Link Configuration DNS Configuration Sideband Interface NC SI PAM Order Settings PAM Authentication Order Platf...
Страница 48: ...5 BMC Configuration Settings Lepus User Manual 5 2 9 Remote Control The Remote Control page displays the configuration for power control and remote KVM Click Java Console to start the JViewer video r...
Страница 49: ...40 Chapter 5 BMC Configuration Settings Lepus User Manual Click Launch KVM to open the Remote KVM page...
Страница 50: ...nual Procedure To Start KVM Step 1 Click Start KVM to start the H5Viewer video redirection Step 2 Click Browse to select CD Image Step 3 Click Start Media to redirect the selected CD image file to the...
Страница 51: ...Mode This option handles mouse emulation from local window to remote screen using either of the two methods Only Administrator has the right to configure this option Absolute mouse mode The absolute p...
Страница 52: ...pressed the CTRL ALT and DEL keys down simultaneously on the server that you are redirecting Left Windows This menu item can be used to act as the left side WIN key when in Console Redirection You can...
Страница 53: ...options of Power Control are given below Power Off To immediately power off the server Power On To power on the server Power Cycle This option will first power off and then reboot the system cold boot...
Страница 54: ...s the BMC s UID control information Users can change the Identify LED behavior on this page Click Chassis Identify Control from the menu bar Select Off On to control UID LED 5 2 12 Set Front Panel Ena...
Страница 55: ...aintenance This Maintenance page displays the configuration settings for Backup Configuration Firmware Image Location Firmware Information BIOS Information Fimware Update Preserve Configuration Restor...
Страница 56: ...cally follow if the upgrade is completed or cancelled An option to Preserve All Configuration is available Enable it if you wish to preserver configured settings through the upgrade Click Start Firmwa...
Страница 57: ...ration Settings Lepus User Manual 5 2 14 Sign out To log out of the BMC Method 1 Click Sign out from the menu bar The Logout dialog box will pop out Method 2 Click the root quick button on the top rig...
Страница 58: ...aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Em...