12Gb/s SAS JBOD Series

User's Manual

Содержание 12Gb/s SAS JBOD Series

Страница 1: ...UM_J4024 01_v6_121619 J4024 01 12Gb s SAS JBOD Series User s Manual...

Страница 2: ...Chapter 3 Sub system Configuration Setup 18 3 1 Supported Configuration on Host 18 3 2 Connect Host to JBOD via RS232 19 3 3 Utility Setup on Host 20 3 4 Updating Firmware and MFG through Console Port...

Страница 3: ...2 3 6 5 SES Element Control Functions 49 Chapter 4 BMC Configuration Settings 57 4 1 Login 57 4 2 Sensor s Location for Fan and Temperature 58 4 3 Utility Setup on Host 59 4 4 Connect Host to BMC by R...

Страница 4: ...Copyright 2017 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 5: ...Document Release History Release Date Version Update Content 2017 1 Manual release to public June 2018 5 Content update December 2019 6 1 New cover 2 BMC update...

Страница 6: ...le for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is prov...

Страница 7: ...y mount the equipment into the rack in such manner that it won t be hazardous due to uneven mechanical loading This equipment is to be installed for operation in an environment with maximum ambient te...

Страница 8: ...ys must not be empty They must have a dummy cover Equipment intended for installed in restricted access location CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used b...

Страница 9: ...p the hardware is highly advised Do not endanger yourself by placing the device in an unstable environment The consequences for negligent actions may be extremely severe Chapter 3 Sub system Configura...

Страница 10: ...he carton are damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and...

Страница 11: ...nd Redundancy Drive Bays 24 Cooling 4 x 60x38mm hot swap fans Power Supply 549W 1 1 hot swap redundant 80 Platinum Power Entry Dual AC Inlet Expander Modules Dual expanders Optional Electrical and Env...

Страница 12: ...g up to 12 Gb s this product enhances these features by integrating hotswap designs redundant fans and expansion to offer easy control and high performance for our customers Intelligent Enclosure Mana...

Страница 13: ...Chapter 1 Product Features J4024 01 User Manual 4 Front Panel Supports hot swappable 24 x 3 5 HDDs...

Страница 14: ...nder Panel 2 Dual Expander Primary Secondary It em Describtion Mini SAS HD Console port Debug port BMC LAN port BMC console port BMC console port BMC LAN port option 3 x Mini SAS HD BMC LAN port optio...

Страница 15: ...r Manual 6 Rear Panel 4 x 6038 hot swap fans 549W 1 1 hot swap redundant power supply Serial port for Remote JBOD Power on off Up to Host or JBOD Down to JBOD Daisy Chain 6 x 48Gb s Mini SAS HD Debug...

Страница 16: ...2 Hardware Setup J4024 01 User Manual Remove the screws on the top cover Slide the top cover towards the rear end of the system barebone Lift the cover upward to remove Chapter 2 Hardware Setup 2 1 T...

Страница 17: ...re Setup J4024 01 User Manual Pull the handle to remove the module out of the chassis Push the new power supply unit into the chassis Ensure that the module is robustly hooked into the cage 2 2 Power...

Страница 18: ...e Setup J4024 01 User Manual Loosen the thumb screws on the fan module Pull the fan module out of the chassis Align the new fan module with the opening in the enclosure Insert the fan module into chas...

Страница 19: ...oosen the lever Pull the tray lever outward completely Pull the tray out of the system Insert the hard disk drive into the tray Ensure that the dimples on the tray match the hard disk drive For additi...

Страница 20: ...11 Chapter 2 Hardware Setup J4024 01 User Manual 2 4 2 Drive Slot Map The drive slot map follows...

Страница 21: ...etup J4024 01 User Manual Detach the cables and hard disk drives from the backplane module Release the module by shifting the hook Dislodge the screws on the module Lift the module upward to remove 2...

Страница 22: ...Loosen the thumb screw to release the expander tray lever Pull the expander module out of enclosure Align the new expander module with the expander slot and insert it into the chassis Close the lever...

Страница 23: ...MC module Expander Remove the expander module from the chassis Please refer to section 2 4 Place the BMC module on the Expander Module Make sure to match the screw holes Secure the screws Insert the n...

Страница 24: ...fer to the manual in the slide rail kit NOTE The product installation position is less than 1 meter in height from the supporting surface 2 8 Slide Rail Installation 7 Slide Rail Installation User s M...

Страница 25: ...onto the rack by following procedure 1a 1b 1a Secure the adjuster plate on the rack using the screws 1b Insert the slide rail into the adjuster plate and make sure the slide rail is fully hooked into...

Страница 26: ...Chapter 2 Hardware Setup J4024 01 User Manual Installing the front of JBOD onto the rack by following the procedure 2a 2b 2a Secure the JBOD on the rack using the screws 2b Complete installing the JB...

Страница 27: ...of wide ports on each AIC 12G expander controller only the followng drives are supported for shared access 1 SAS drive 2 SATA drive with an interposer which provides SATA to SAS conversion Host Each...

Страница 28: ...Chapter 3 Sub system Configuration Setup Use a RS 232 DB9 cable to connect the console port of JBOD with host s PC COM port see figures below for DB9 RS 232 cable and SAS expander COM port 3 2 Connect...

Страница 29: ...tep 1 Set up host RS232 connection Set up RS232 connection application into your host as shown in the example process below For example OS Microsoft Windows Server 2008 RS232 connection application Hy...

Страница 30: ...Sub system Configuration Setup Step 3 Enter a new name for the icon in the field below and click OK Step 4 Connect by using selecting an option in the drop down menu circled in red below we selected...

Страница 31: ...r Manual Step 6 After step 5 you will enter hyper terminal screen Please press the Enter key and the cmd line will appear on the screen Step 5 Under Bits per second select 38400 Under Flow control sel...

Страница 32: ...Chapter 3 Sub system Configuration Setup Step 1 Please input fdl 0 0 in command line to update the firmware Step 2 Select the tool bar Transfer Send File within 10 seconds 3 4 Updating Firmware and M...

Страница 33: ...Configuration Setup J4024 01 User Manual Step 3 Select the Firmware file and set the Protocol type as Xmodem Then press the Send button Step 4 After completing the FW update Buffer Download Complete...

Страница 34: ...0 in commond line to update the MFG Step 6 Go to the Transfer menu and then select Send file within 10 seconds Step 7 Select the MFG file and set the Protocol type as Xmodem Then press the Send button...

Страница 35: ...al 3 5 1 How to enable disable T10 zoning The default T10 zoning configuration is off A Check the current zoning state cmd phyzone state Zoning is OFF B Enable zoning cmd phyzone on C Disable zoning c...

Страница 36: ...drive accessed only by the second port The configuration for the example is A PHY0 PHY3 for the first wide port B PHY4 PHY7 for the second wide port C PHY12 PHY35 for drive Step 1 Read the current gro...

Страница 37: ...group for the phy cmd phyzone 7 9 Succeeded to set zone group for the phy cmd cmd cmd cmd cmd _ cmd phyzone 0 8 Succeeded to set zone group for the phy cmd phyzone 1 8 Succeeded to set zone group for...

Страница 38: ...00 cmd showmfg Manufacturing Image Version Information Mfg Revision 1 1 0 4 Product Name SAS3_HOTSWAP Platform Name AIC 12G cmd _ cmd sensor ENCLOSURE STATUS Total fan number 2 System Fan 0 speed 1088...

Страница 39: ...n Celsius t1 20 C t2 55 C warning 50 C alarm 55 C B Set temperature with new T1 18 C T2 52 C warning threshold 48 C and alarm threshold 54 C The new setting will take effect after reset cmd temperatur...

Страница 40: ...500605B0000272BF B Set the enclosure address with 0x500605B0000272BF The new setting will take effect after reset cmd enclosure_addr 500605B0000272BF cmd reset cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd...

Страница 41: ...Standby timer is in units of minutes Setting standby timer with 0 minute disables this feature A Get current standby timer cmd standby_timer Standby Timer 0 minutes B Set the standby timer with 10 min...

Страница 42: ...e power consumption of SAS drives Otherwise AIC Expander Controller starts all attached SAS drives to provide drive access service to any active SAS initiator The same setting should be applied to HUB...

Страница 43: ...34 Chapter 3 Sub system Configuration Setup J4024 01 User Manual...

Страница 44: ...der number 421 12021704510010 or Expander number 421 12021704510010 Enclosure number 526 12071100500088 B Only set Expander serial number with 421 12021704510010 cmd serial_number 421 12021704510010 C...

Страница 45: ...tive SAS initiator by checking all wide ports AIC Expander Controller powers off all attached SAS SATA drives to save power consumption Otherwise AIC Expander Controller powers on all attached SAS SAT...

Страница 46: ...Chapter 3 Sub system Configuration Setup 3 5 10 How to configure EDFB The default EDFB configuration is off A Check the current configuration cmd edfb EDFB is OFF B Enable the edfb cmd edfb on C Disab...

Страница 47: ...ing on AC power loss Three supported options are keep off keep on and keep last state The default setting is keep off A Get the current power setting cmd power_setting Power setting keep off B Set kee...

Страница 48: ...39 J4024 01 User Manual Chapter 3 Sub system Configuration Setup...

Страница 49: ...formation please visit http www t10 org If you are a member of the T10 working group the Standard which controlled by T10 technical committee could be found at http www t10 org cgi bin ac pl t f f ses...

Страница 50: ...odule2 STATUS_WORD Byte 5 14 Reserved 0xFF 3 6 3 2 SES Threshold Out In It includes only Temperature Sensor and Voltage Sensor elements Threshold control element format BYTE BIT 7 6 5 4 3 2 1 0 0 REQU...

Страница 51: ...unctions for details B Power Supply Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE 1 IDENT Reserved 2 Reserved DC OVER VOLTAGE DC UNDER VOLTA...

Страница 52: ...ent Control Functions for details B Cooling Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE 1 IDENT Reserved ACTUAL FAN SPEED MSB 2 ACTUAL FAN...

Страница 53: ...TUS CODE 1 IDENT FAIL Reserved 2 TEMPERATURE 3 Reserved OT FAILURE OT WARNING UT FAILURE UT WARNING Field Value ELEMENT STATUS CODE OK Everything is Ok NON CRITICAL If either warning limit is exceeded...

Страница 54: ...to section SES Element Control Functions for details REQUEST WARNING Please refer to section SES Element Control Functions for details B Enclosure Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STAT...

Страница 55: ...NTROL SELECT PRDFAIL DISABLE RST SWAP Reserved 1 RQST IDENT RQST FAIL Reserved 2 Reserved 3 Reserved B Voltage Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELE...

Страница 56: ...CHECK Please refer to section SES Element Control Functions for details RQST IN CRIT ARRAY Please refer to section SES Element Control Functions for details RQST IN FAILED ARRAY Please refer to secti...

Страница 57: ...e Control Element RSVD DEVICE Set by the RQST RSVD DEVICE on Array Device Control Element HOT SPARE Set by the RQST HOT SPARE on Array Device Control Element CONS CHK Set by the RQST CONS CHECK on Arr...

Страница 58: ...and When the RQST IDENT bit is set the blue LED overwrites its default behavior with a slow blink while the red LED is off The blue LED is set Activity for not overwriting its default behavior The beh...

Страница 59: ...element in the SES specification Set the bit to turn off a slot power and vice versa We use the software package sg3_utils on Linux for example and have a SAS HBA and a cable to connect your host wit...

Страница 60: ...ecification Clear the bit on Power Supply Element DiskPowerSupply to power off all disk drives Set the bit on Power Supply Element DiskPowerSupply to power on all disk drives We use the software packa...

Страница 61: ...r Supply is defined in the bit5 byte3 of the Power Supply control element in the SES specification Clear the bit on Power Supply Element PowerSupply01 or PowerSupply02 to power off the entire enclosur...

Страница 62: ...abled When blinking the identity is enabled The RQST IDENT for Enclosure is defined in the bit7 byte1 of the Enclosure control element in the SES specification Set the bit to enable the identity Clear...

Страница 63: ...bit1 byte3 and bit0 byte3 of the Enclosure control element in the SES specification Setting either bit can enable the enclosure alarm Clearing both bits disables the enclosure alarm We use the softwar...

Страница 64: ...Cooling elements by setting the REQUESTED SPEED CODE bits Clear RQST IDENT bit to enable the smart fan function again Please disable the smart fan function before changing PWM or fan speed Only Coolin...

Страница 65: ...56 Chapter 3 Sub system Configuration Setup J4024 01 User Manual REQUESTED SPEED CODE PWM 7 100 6 90 5 80 4 70 3 60 2 50 1 40 0 Leave at current speed...

Страница 66: ...a web browser and enter the default IP http 192 168 11 11 When the login window appears set the user name and password to admin Click Log In to continue Type the default account and password Account a...

Страница 67: ...58 Chapter 4 BMC Configuration Settings J4024 01 User Manual Fan1 FRONT Fan0 T0 EXP expander chip 4 2 Sensor s Location for Fan and Temperature...

Страница 68: ...Host to BMC by RS232 1 Type the and it will show the IPMI serial interface Type in the command for logging in the interface sys pwd u admin admin It will response OK Type in the command for checking t...

Страница 69: ...30 00 02 01 04 00 00 Find LAN IP 30 00 02 01 03 00 00 Find submask 30 00 02 01 06 00 00 Find gateway 30 00 02 01 0C 00 00 Get LAN static IP DHCP 01 is static IP 02 is DHCP The red box is hexadecimal...

Страница 70: ...00 0A Set submask 30 00 01 01 06 FF FF FF 00 Set gateway 30 00 01 01 0C C0 A8 00 01 The Green returns text that in red box is completion code 00 means OK The blue text can change the value what you w...

Страница 71: ...4 BMC Configuration Settings J4024 01 User Manual There are have two LEDs under the BMC console port Blue LED Light Identify LED Red LED Light When the light keep blinking means BMC got error 4 5 BMC...

Страница 72: ...console preview Sensor Monitoring It lists all available sensors on the device with information such as status name reading and status icon as well as a link to that sensor s page There are 3 possible...

Страница 73: ...Chassis information fields Area Format Version Chassis Type Chassis Part Number Chassis Serial Number Chassis Extra Board Information It displays the following Board information fields Area Format Ve...

Страница 74: ...atus using the Power On and Power Off button to control HDD status ACTIONS Power On Select a HDD to turn it power on Power off Select a HDD to turn it power off Icon status Green This slot inserted HD...

Страница 75: ...representation of all associated events Double click on a record to toggle ON OFF the live widget for that particular sensor You can filter the list to view particular sensors only using the drop dow...

Страница 76: ...he device BMC Timezone Check this option to display the event log entries logged with the BMC Timezone value Client Timezone Check this option to display the event log entries logged with the Client u...

Страница 77: ...t to register with the DNS settings Check the option Register BMC to register with the DNS settings Choose the option Direct Dynamic DNS to register with direct dynamic DNS or choose DHCP Client FQDN...

Страница 78: ...guration DNS Server 1 2 3 Specify the DNS Domain Name System server address to be configured for the BMC An IPv4 Address is made of 4 numbers separated by dots as in xxx xxx xxx xxx Each number ranges...

Страница 79: ...y IPv4 Configuration It lists the IPv4 configuration settings Obtain an IP address automatically Enable Use DHCP to dynamically configure the IPv4 address using Dynamic Host Configuration Protocol DHC...

Страница 80: ...uration Protocol DHCP IPv6 Address Specify a static IPv6 address to be configured for the selected interface Subnet Prefix length Specify the subnet prefix length for the IPv6 settings Value ranges fr...

Страница 81: ...are to be configured Auto Negotiation This option is enabled to allow the device to perform automatic configuration to achieve the best possible mode of operation speed and duplex over a link Link Spe...

Страница 82: ...a year 2038 problem exists the acceptable date range is from 01 01 2005 to 01 18 2038 NTP Server Specify the NTP Server for the device Check the Automatically synchronize option to configure the NTP...

Страница 83: ...Manual Correct UTC Check this option to automatically synchronize Date and Time with the NTP Server Refresh Click Refresh to reload the current date time settings Save Click Save to save any changes...

Страница 84: ...w configured Alert policies and available slots You can modify or add new alert policy entries here A maximum of 60 slots are available LAN Destination Click the LAN Destination tab to show configured...

Страница 85: ...and click Add to add a new entry to the device Alternatively double click on a free slot Modify Select a configured slot and click Modify to modify that entry Alternatively double click on the config...

Страница 86: ...meric characters Space special characters are not allowed Primary SMTP Server It lists the Primary SMTP Server configuration SMTP Support Check this option to enable SMTP support for the BMC Server Ad...

Страница 87: ...ric characters It must start with an alphabet Special characters comma colon semicolon space and backslash are not allowed Password Enter the password for the SMTP User Account Passwords must be at le...

Страница 88: ...ration Settings 4 6 5 7 Schedule This page displays the device s current date time It can be used to configure dates within a week or specific a date to power on off the device If you want to change t...

Страница 89: ...able schedule Check this option for enable disable the schedule Action Check a action to do power on off for the device Set days for action Setting dates within a week to do power on off for the devic...

Страница 90: ...ified as a security measure To view the page you must have Operator privileges To modify or add a user You must have Administrator privileges NOTE Free slots are denoted by in all columns for the slot...

Страница 91: ...cycle operations Reset Expander Select an expander to do cold reset Power Off Storage Select this option to immediately power off the storage Power On Storage Select this option to power on the stora...

Страница 92: ...installed in the system prior to the launch of the JNLP file Launch the Java SOL you must have Administrator privileges Choose an expander that can use smart console in Java SOL Volatile Bit Rate Plea...

Страница 93: ...edhat 6 4 NOTE If you want to update a new version firmware for BMC please clear the web browser cookies when the update process is complete 4 7 2 Web update 1 Check if the BMC IP is valid 2 Open a br...

Страница 94: ...85 J4024 01 User Manual Chapter 4 BMC Configuration Settings 3 This is login main page 4 Click the Firmware Update and it will pop a drop down menu Click the Firmware Update...

Страница 95: ...J4024 01 User Manual 5 This page will display the update warning Click the Enter Update Mode button to update the BMC firmware 6 Wait few minutes and it will pop a window Click the Select file to upl...

Страница 96: ...apter 4 BMC Configuration Settings 7 Wait a few minutes and it will pop a window for check update section Select the Check this option to do all full firmware flash option 8 Click OK the firmware to s...

Страница 97: ...ll take 3 5 minutes to complete firmware update NOTE Please do not close this webpage during the update process to prevent the system from crashing down 10 When show the Device has been reset window i...

Страница 98: ...Manual Chapter 4 BMC Configuration Settings 1 Click the Firmware Update and it will pop a drop down menu Click the Expand Update 2 Choose the expander firmware file that you want to update 4 8 Expande...

Страница 99: ...90 Chapter 4 BMC Configuration Settings J4024 01 User Manual 3 Choose the expander firmware file then click the upload button 4 Click the Proceed button...

Страница 100: ...91 J4024 01 User Manual Chapter 4 BMC Configuration Settings 5 Processing 6 Update successful...

Страница 101: ...92 Chapter 4 BMC Configuration Settings J4024 01 User Manual 7 If the update processes is not successful Please check the expander firmware is latest version or the system power is turned off...

Страница 102: ...ils or the primary firmware suffers some error it will boot into safety mode 1 If you see the sensor name status LED and ID LED are abnormal the LEDs are cross blinking it means the firmware is in saf...

Страница 103: ...ngs J4024 01 User Manual 2 Please clear browser cookies and re start browser The BMC web UI will refresh the web page object 3 Click the BMC Reset button to enter the reset page 4 Select the BMC reset...

Страница 104: ...The page will show Requesting This web page will be invalid because of resetting the BMC Wait 90 seconds and clear browser cookies to re login web UI again 6 If you still see the safety mode page ple...

Страница 105: ...Sales Email support ru aicipc com tw Support Email support ru aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 67...