AHP ALPHA-CUT60 Скачать руководство пользователя страница 1

 

PLASMA CUTTER 

 

 

 

 
 

 

 
  

              OWNER'S MANUAL

 

 
 
 
 
 
 
 
 
 

MODEL:

ALPHA-CUT60 

(INVERTER POWERED PLASMA CUTTING POWER SUPPLY)

 

 
 
 
 

 

 

Содержание ALPHA-CUT60

Страница 1: ...PLASMA CUTTER OWNER S MANUAL MODEL ALPHA CUT60 INVERTER POWERED PLASMA CUTTING POWER SUPPLY ...

Страница 2: ... ALPHA CUT 60 uses non HF cutting technology A blowback style torch is used to allow for easy cutting through rusted painted surfaces without having to clean the surface prior to being able to start the cutting arc as other HF ONLY models require Adjustable post flow allows cooling of the torch tips which in turn gives a longer consumable life Some of the characteristics of our ALPHA Cut are as fo...

Страница 3: ...2 ...

Страница 4: ...3 ...

Страница 5: ...4 The panel picture above is for reference only and subject to change ...

Страница 6: ...sing your fingers Do not overtighten the connection as it can cause damage 3 Connect the terminal ring eye wire to the pilot arc grounding screw beside the plasma torch connection Then connect the 2 pin Amphenolplug for the trigger control Finally connect the work lead Ground clamp connection to the red dinse connection CHECK 1 Check if the plasma cutter is grounded reliably according to local sta...

Страница 7: ... for air flow to and from all vents 2 Correct voltage must be used for all amp settings either on 110v or 220v the voltage drop cannot go lower than 105 volts on 110v or 210 volts on 220v Do not exceed load or operate at maximum duty cycle on a constant basis as this will shorten the life of various internal components 3 Voltage Range The power voltage range of the plasma cutter is shown on the te...

Страница 8: ... ground is bad problems will arise with poor cutting quality and loss of cutting arc MAINTENANCE AND TROUBLE SHOOTING Maintenance 1 Regularly remove dust by using compressed air If the Plasma cutter is used or stored in a dusty environment where a high volume of dust smoke or metal particles accumulate periodically remove the casing and carefully clean the interior using compressed air It is impor...

Страница 9: ...fan is working However when control knob of torch is activated there is no arc striking sound and interior red diode light is on Check if MOS FMH23N50E chips on top board are damaged driver module is damaged Step up transformer on bottom board is damaged Control module is damaged 4 Switch indicator is lit and fan and electromagnetic solenoid valve areworking however the interior red diode is not l...

Страница 10: ...d a failure with these items occur at AHP Welds discretion AHP Welds will not be responsible for time contract loss from unit failure damages occurring from improper or unskilled operation damages resulting from improper maintenance improper wiring poor quality power sources abuse or neglect Nor will AHP assume responsibility for the customer s failure to heed read safety instructions to read and ...

Страница 11: ...10 ...

Отзывы: