installation manual 

1.    PRECAUTIONS 

The safty precautions listed here are divided into two categories.  

After completing the installation, make sure that the unit operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.Also, inform 
customers that they should store this installation manual along with 
the owner's manual for future reference.  

Be sure only trained and qualified service personnel to 
install, repair or service the equipment. 
 

Improper installation, repair, and maintenance may result in 
electric shocks, short-circuit, leaks, fire or other damage to 
the equipment. 

CONTENTS PAGE 

PRECAUTIONS.......................................................................................1

INSTALLATION INFORMATION...............................................................2

ATTACHED FITTINGS.............................................................................3

INSPECTING AND HANDLING THE UNIT.................................................4

INDOOR UNIT INSTALLATION................................................................4

OUTDOOR UNIT INSTALLATION.............................................................5

INSTALL THE CONNECTING PIPE...........................................................9

CONNECT THE DRAIN PIPE..................................................................11

WIRING.................................................................................................12

TEST OPERATION.................................................................................13

Install according to this installation instructions strictly. 

 

If installation is defective, it will cause water leakage, 
electrical shock and fire. 
 

When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

 

 

Use the attached accessories parts and specified parts 
for installation. 

 

otherwise, it will cause the set to fall, water  leakage, 
electrical shock and fire. 
 

Install at a strong and firm location which is able to 
withstand the set' s weight. 

 

If the strength is not enough or installation is not properly 
done, the set will drop to cause injury. 
 

The appliance shall not be installed in the laundry. 
 
Before obtaining access to terminals, all supply circuits 
must be disconnected. 
 
The appliance must be positioned so that the plug is 
accessible. 
 
The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow. 

 

For electrical work, follow the local national wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

 

If electrical circuit capacity is not enough or defect in 
electrical work, it will cause electrical shock fire. 
 

Use the specified cable and connect tightly and clamp 
the cable so that no external force will be acted on the 
terminal.

  

If connection or fixing is not perfect, it will cause heat-up or 
fire at the connection. 

 
Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

 

If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical 
shock. 
 

If the supply cord is damaged, it must be replaced by the 
manufacturer or its service agent or a similarly qualified 
person in order to avoid a hazard. 
 
An all-pole disconnection switch having a contact 
separation of at least 3mm in all poles should be 
connected in fixed wiring. 
 
When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle.  

Otherwise, it will cause lower capacity, abnormal high 
pressure in the refrigeration cycle, explosion and injury. 
 

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

 

Otherwise, it will cause fire or electrical shock. 

 
Carry out the specified installation work after taking into 
account strong winds, typhoons or earthquakes. 

Improper installation work may result in the equipment falling 
and causing accidents. 

CAUTION 

WARNING 

WARNING 

If you do not follow these instrutions exactly, the unit may 
cause property damage, personal injury or loss of life.

If you do not follow these instrutions exactly, the unit may 
cause minor or moderate property damage, personal 
injury.

keep this manual where the operator can easily find them.  
 
Read this manual attentively before starting up the units. 
 
For safety reason the operator must read the following 
cautions carefully. 
 
Installation must be performed in accordance with the 
requirement of NEC and CEC by authorized personnel only. 
 

Содержание Ceiling Type

Страница 1: ...Ceiling And Floor Type INSTALLATION MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference...

Страница 2: ...ction of the fluid flow For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical...

Страница 3: ...not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditioner in the following circums...

Страница 4: ...me spare fittings please restore them carefully QUANTITY SHAPE NAME 5 Owner s manual 6 Installation manual 7 Remote controller manual 1 Remote controller on some models 2 Remote controller holder on s...

Страница 5: ...When handling the unit take into account the following Fragile handle the unit with care Keep the unit upright in order to avoid compressor damage Choose on before hand the path along which the unit...

Страница 6: ...Table 5 1 6 1 Installation Place 6 OUTDOOR UNIT INSTALLATION The outdoor unit should be installed in the location that meets the following requiements unit mm Fig 5 10 Fig 5 11 Fig 5 12 D Connecting...

Страница 7: ...outdoor unit The condensate should be well drained away by the drain hole to an appropriate place so as not to interfere other people Select the position where it will not be subject to snow drifts a...

Страница 8: ...ODEL A B C D E H REMARK F 24 18 30 36 845 560 335 360 312 700 320 900 590 333 355 302 860 315 990 624 366 396 340 965 345 990 624 366 396 340 965 345 990 624 366 396 340 965 345 990 624 366 396 340 96...

Страница 9: ...6 15 Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind Refer to Fig 6 15 NOTE NOTE Four different configuration are available for oudoo...

Страница 10: ...unit No Description Outdoor Unit Vibration proof rubber Anchor Bolt M10 Drainage Wide 100 Depth 150 Drainage Mortar Hole 100 Depth 150 Sling Bolt Suspension Bracket Table 6 4 Table 6 5 Fig 6 17 MODEL...

Страница 11: ...akage Please determine the torque according to Table 7 2 After the connecting work is finished be sure to check that there is no gas leak When connecting the flare nut coat the flare both inside and o...

Страница 12: ...rge hose with the vacuum pump Open the Lo lever of the manifold value completely Turn on the vacuum pump At the beginning of pumping loosen the maintenance nut of stop valve B a little to check whethe...

Страница 13: ...s position is shown figure below Drain Piping Fig 8 2 Fit the seal into the drain joint then insert the drain joint into the base pan hole of outdoor rotate 900 to securely assemble them Connect the d...

Страница 14: ...Whether the generated wind noise or condensed of by the air conditioner have influenced your neighborhood c Whether any of the refrigerant is leaked A protection feature prevents the air conditioner...

Страница 15: ...1Phase 208 240V 1Phase MODEL POWER CIRCUIT BREAKER FUSE A PHASE FREQUENCY AND VOLT 30 36 30 36 42 60 42 60 380 420V 25 20 25 20 40 25 45 35 208 240V 3Phase 380 420V 3Phase 3Phase 208 240V 3Phase Tabl...

Страница 16: ...0 36 30 36 42 60 42 60 380 420V 25 20 25 20 40 25 45 35 208 240V 3Phase 380 420V 3Phase 3Phase 208 240V 3Phase Table 9 5 Table 9 6 PHASE FREQUENCY AND VOLT POWER indoor POWER outdoor 30 20 30 20 40 30...

Страница 17: ...er wiring indoor Power linking wiring Outdoor Strong elec signal link wiring Weak elec signal link wiring Indoor Unit Outdoor Unit Ground the air conditioner properly in case to affect its anti interf...

Страница 18: ...in all active conductors should be incorporated in the fixed wiring according to the National Wiring Regulation When wiring please choose the corresponding chart or it may cause damage The signs of th...

Страница 19: ...tallation manual QSDLI 016AEN The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details 202000192522 20...

Страница 20: ...19 installation manual...

Страница 21: ...20 installation manual...

Страница 22: ...21 installation manual...

Страница 23: ...22 installation manual...

Страница 24: ...33...

Страница 25: ...34...

Отзывы: