background image

Installation, Operation & Maintenance                                                                         Parksafe Gas Detector 

 

 

Rev: 11      0421

 

3  

 

Important Warning Statements 

 

Before any installation, use or maintenance read this manual carefully. 
The information contained within this manual should be referenced for typical installation and operation only.  
For site specific requirements that may deviate from the information in this guide – contact your supplier.  
If this device is used in a manner not specified by the manufacturer, the safety and provided by this device may be impaired. 
This device is designed for indoor operation only. 
The expected lifetime of a NO

gas sensor element is 2 years upon initial power up. The Parksafe control panel will display a 

message to indicate this time and detectors should immediately be replaced. 
The expected lifetime of a CO gas sensor element is 5 years upon initial power up. The Parksafe control panel will display a 
message to indicate this time and detectors should immediately be replaced. 
It is recommended that this device be commissioned upon installation and serviced annually. 
Do not apply lighter gas or other aerosols to the device – this will cause extreme damage. 
High concentrations of alcohol / ethanol found in many products may damage, deteriorate or affect the gas sensing elements 
– Avoid exposure near your device. 
This equipment is designed to detect carbon monoxide and nitrogen dioxide from any source of combustion.  
It is NOT designed to detect smoke, fire or other gases and should NOT be used as such. 
DO NOT remove the gas sensing module when the system is powered up. 
This device provides early warning of the presence of nitrogen dioxide or carbon monoxide, usually before a healthy adult 
would experience symptoms. This early warning is possible provided your alarm is located, installed and maintained as 
described in this guide. 
This device requires a continual supply of electrical power – it will not work without power. 
This device should not be used to substitute proper installation, use and / or maintenance of fuel burning appliances 
including appropriate ventilation and exhaust systems. 
This device does not prevent nitrogen dioxide or carbon monoxide from occurring or accumulating. 
Actuation of your alarm indicates the presence of dangerous levels of NO

2

 or CO.  

Seek fresh air supply and contact your local gas emergency service should you suspect a gas leak. 
This device may not fully safeguard individuals with specific medical conditions.  
If in doubt, consult a doctor / physician. 
Your product should reach you in perfect condition, if you suspect it is damaged, contact your supplier. 

 

 

Manufacturer’s Warranty

 

 

 

Coverage: The manufacturer warrants to the original consumer purchaser, that this product will be free of defects in material and 
workmanship for a period of three (3) years from date of purchase. The manufacturer’s liability hereunder is limited to replacement 
of the product with repaired product at the discretion of the manufacture. This warranty is void if the product has been damaged by 
accident, unreasonable use, neglect, tampering or other causes not arising from defects in material or workmanship.  
This warranty extends to the original consumer purchaser of the product only. Disclaimers: Any implied warranties arising out of 
this sale, including but not limited to the implied warranties of description, merchantability and intended operational purpose, are 
limited in duration to the above warranty period. In no event shall the manufacturer be liable for loss of use of this product or for any 
indirect, special, incidental or consequential damages, or costs, or expenses incurred by the consumer or any other user of this 
product, whether due to a breach of contract, negligence, strict liability in tort or otherwise. The manufacturer shall have no liability 
for any personal injury, property damage or any special, incidental, contingent or consequential damage of any kind resulting from 
gas leakage, fire or explosion. This warranty does not affect your statutory rights. Performance: During the above warranty period, 
your product will be replaced with a comparable product if the defective product is returned together with proof of purchase date. 
The replacement product will be in warranty for the remainder of the original warranty period or for six months – whichever is the 
greatest.  
 

 
Information on waste disposal for consumers of electrical & electronic equipment.

 

 

When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE). Any 
WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and 
recycling of the materials used. Please contact your supplier or local authority for details of recycling schemes in your area. 

 
At the end of their working life, electrochemical sensors for parksafe detectors should be disposed of in an environmentally safe 
manner.Alternatively all detectors can be securely packaged and returned to AGS clearly marked for disposal. 
Electrochemical sensors should not be incinerated as this may cause the cell to emit toxic fumes.  

Содержание Carbon Monoxide

Страница 1: ...The Parksafe gas detection range designed for installation into car parking facilities and enclosed garages paired with the Parksafe control panel which will monitor up to 16 gas detectors per panel p...

Страница 2: ...ernal Board Overview 5 Wiring a Detector 6 Wiring a Detector Chain 6 Detector ID Switches 7 120ohm Termination Resistance 7 Quick Circuit Test 7 Operation 8 First Power Up 8 LED Indications 8 Alarm Se...

Страница 3: ...s If in doubt consult a doctor physician Your product should reach you in perfect condition if you suspect it is damaged contact your supplier Manufacturer s Warranty Coverage The manufacturer warrant...

Страница 4: ...target gas and its density relative to air are used as the basis for the recommended height of gas detectors These heights may vary based on air flow and temperature conditions in addition to the prop...

Страница 5: ...ition as per the recommended heights and in accordance with applicable local national regulations After executing the mounting connections and ID switches secure the front cover Carbon Monoxide CO gas...

Страница 6: ...should be connected to of the chain terminals Reversing the D and D connections of any device can lead to the whole system to stop working owing to reverse polarity found on the terminals The detector...

Страница 7: ...on Resistance Signal communication issues may occur where the bus length is too long high baud rates are used or signal reflections are occurring To avoid this terminating at each end of a chain may h...

Страница 8: ...h off and the detector will be in operation Check your Parksafe panel for the gas detector status We recommend all gas detection systems be commissioned by a competent trained engineer to ensure corre...

Страница 9: ...t person This test does not check the gas sensing element itself Annual Service Message It is recommended that detectors be serviced at least annually from the date of installation for optimum perform...

Страница 10: ...act your S S Northern representative for details of suitable bump testing kits and gases Kits usually consist of a certified gas cylinder flow control regulator tube pipe and applicator cone We recomm...

Страница 11: ...sed in potentially explosive atmospheres Indicators LED Green Power Yellow Fault State Red Alarm Orientation Wall Mounted Electrical Max Power Consumption 15mA Max 24Vdc Power Voltage Input Range 12 3...

Страница 12: ...erforms as intended and is free from any unforeseen damage caused by transit installation Every effort is made to ensure the accuracy of this document however AGS can assume no responsibility for any...

Отзывы: