AGS 2500/3000 EN-HP
USER MANUAL – rev.2016/12
page
29
7.11.3
Partial cleaning of sprayer
Partial cleaning of sprayer includes cleaning of filter, pump, pressure regulator and nozzles,
without changing crop protection liquid concentration in main tank. Switch valve for
discharge from additional tank (pos. 16 – figure 18) in direction towards suction valve (pos. 7
– figure 18). Direct the valve to suck from the additional tank with clean water. Use three-way
valve (pos. 8 – figure 18) to direct excess water through filter back to the pump and direct the
selection valve to spraying. Clean water has open flow through filter, pump, pressure
regulator and all nozzles, through which the system is completely discharged. Crop protection
liquid concentration in main tank remains the same.
Direction of valve flow is marked on the valve lever with an arrow. Correct setting of valves
for partial cleaning of sprayer is displayed in the figure below (figure 17).
WARNING:
Perform complete or partial cleaning after finishing spraying on the
field, which you have sprayed. Empty the tank or system through nozzles while
driving at half hectare consumption and increased driving speed on already
sprayed field!
Figure17: PARTIAL CLEANING OF SPRAYER
Содержание AGS 2500 EN-HP
Страница 2: ......
Страница 8: ...VI...
Страница 10: ...VIII...
Страница 113: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 103 PARAMETER VALUE NOTE imp l d1 d2 d3 d4 d5 d6 d7 D Imp km l ha...
Страница 120: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 110 14 3 Dimensions and weight...
Страница 127: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 117 16 COMBINATION MATRIX 16 1 Combination matrix AGS 2500 EN HP...
Страница 128: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 118 16 2 Combination matrix AGS 3000 EN HP...
Страница 129: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 119 17 NOTES...
Страница 130: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 120...
Страница 131: ......