![Agrio Gigant Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/agrio/gigant/gigant_instruction-manual_2869980076.webp)
16.4.7
Summa
16.4.8
ry of the main points
-
Pump speed max. 540 rpm.
-
Avoid frequent shutdown of the pump using the drive coupling; if there is no other solution,
make sure that the drive coupling is re-engaged at low speed.
-
Initially run the cold pump at low speed.
-
Avoid the formation of a vacuum in the suction paths - there is a possibility of rupture of the
diaphragms!
-
The suction filter must always be well cleaned.
-
The main cock between tank and pump must not be closed.
-
There must be no foreign bodies in the suction hoses.
-
After each tank filling, check the entire suction paths to avoid clogging the pump inlet.
-
Symptoms of diaphragm rupture - oil loss from the pump or emulsion formation in the oil
expansion tank -
shut down the machine immediately and repair the pump
.
16.5
Calibration of the flow meter
-
Calibrate the flow meter at least once a year.
-
Always calibrate the flow meter:
- After disassembly of the flow meter
- after prolonged operation, as chemical residues may be deposited on the flow meter
- if there isa difference between the actual and the calculated application rate
-
Calibrate the flow meter separately for water and DAM 390
-
Calibrate the flow meter according to the instructions for the particular type of computer.
16.6
Connection for sprayer test/inspection
1-
Connection point pump
2-
Connection point pressure side (if available)
1
2
Содержание Gigant
Страница 1: ...Instruction manual GIGANT ver 1 2022 ...
Страница 16: ...4 3 1 Location of the safety labels BZ 3 BZ 3 BZ 3 BZ 4 BZ14 BZ 5 BZ 7 BZ 8 BZ 9 BZ 6 ...
Страница 66: ......
Страница 78: ......
Страница 82: ......
Страница 88: ...19Attachments 19 1 Hydraulic diagram of the sprayer ...
Страница 89: ...19 2 Sprayer water scheme ...