5 Maintenance and Repair
58
Hydrostatic Implement Carrier
agria 5900 Bison
Dry air filter
Prior to each startup, check the air filter (D/4) for
contamination. Clean if necessary.
At the latest every
50
operating hours or every
3
months
. After a few hours in very dusty environ-
ments.
Clean air filter and surrounding area.
Loosen the wing nut (1), remove air filter cover
(4) and cyclone prefilter (5).
Rotate the air filter cover (4) such that any dirt
falls out of the cyclone prefilter (5)
Carefully pull off the foam prefilter (3).
Wash the foam prefilter in soapy water (no not
use petrol).
Squeeze out the foam prefilter and dry it.
Remove the filter element (2).
Knock out the filter element on a level surface.
Do not blow out foam prefilter or filter element
with compressed air, or soak it with oil!
Insert the filter element and the foam prefilter.
Position the air filter cover and tighten the
wing nut.
Replace the filter element after every
400
operat-
ing hours or
at least yearly
.
Replace a damaged filter element immedi-
ately.