GENERAL INFORMATION 

 

• 

LED lights indicate when the sensor is firing (spraying).  

• 

Jockey wheel pressure is 20 psi 

• 

Operating height is 65 to 75 cm above the ground, at 70cm it gives the sensor a 
60cm field of view, this is the same width as the nozzle sprays. 

• 

Don’t leave folded up, 1 day in the sun will damage the sensors 

• 

Maximum operating speed is 16 to 17 KPH 

• 

Do not exceed 3 bar operating pressure on the Weedseeker spray line ( the goyen 
solenoids are direct acting plunger type ) 

• 

Every 3 to 4 hours check sensors & solenoids by passing a green leaf under the 
sensors 

• 

Changing light conditions will require regular recalibration.  

• 

When working in variable soil types, calibrate over the lightest coloured soil. 

• 

Voltage is most important, any change in voltage will effect the sensitivity of the 
sensors 

• 

The recommended sensitivity setting is 4 to 5 in stubble conditions, a lower setting 
will cause misfires. 

WIRING INFORMATION 

 

 

 
The largest wiring harness is 1 long continuous cable to give power to the sensors, 
when they see green the valve driver acts as a switch and sends power to the goyen 
solenoids & LED lights .  
 
The main harness is wired like Christmas tree lights. 
 
Line controllers: 

• 

The left hand 2 pin plug is to power up the line controller,direct from the weed-

seeker battery.          

• 

The right hand side 21 pin deutsch plug is from the in cab control box. 

• 

The middle 2 plugs are the daisy cables linking each sensor. 

 

100 amp blade fuse 

Located at the tractor battery on 2 pin grey lead for trickle charge 

100 amp mega fuse 

From battery to isolation switch 

40 amp midi fuse 

To power goyen solenoids, 1 for each section 1,2 & 3. 

15 amp blade fuse 

To power line controllers 1,2 & 3. 