4
IMPORTANT SAFETY INFORMATION ABOUT
PROPANE (LP) GAS
A LP-gas cylinder for use with this appliance must have a capacity of
9 kgs / 20
lbs
. and must be equipped with a Type 1 connector and an OPD (overfill protection
device). Figure 1
The LP-gas supply cylinder to be used must be constructed and marked in
accordance with the specification for LP-gas cylinders of the U.S. Department of
Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339,
Cylinder, Sphere and Tubes for the Transportation of Dangerous Goods
.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and shall
not be used in a building, garage, or any other enclosed space.
When this appliance is not in use, the gas must be turned off at the supply
cylinder.
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the reach of
children. Disconnected cylinders must have threaded valve plugs tightly
installed and must not be stored in a building, garage or any other enclosed
areas.
The gas hose is routed through a “U” bolt to prevent the hose from coming in contact
with the burner. DO NOT remove the hose from the “U” bolt. See Figure 2.
SPECIFICATIONS
The maximum inlet supply pressure,as follows:
“Max.gas supply:6922 in wc (1723Kpa)”
INPUT 30,000
Btu/hr(8.8kW)
Clearances to
combustible surfaces
Sides 60.96 cm / 24 inches
Top:182.8cm/72 inches
Propane Regulator
Pressure
2.74 kpa / 11 in water column
Natural Gas Minimum
Inlet Pressure
1.74 kpa / 7 in water column
Figure 1
Figure 2
Regulator hose
pointed down
Содержание 4000904
Страница 34: ...34...