background image

Agilent Technologies

 

Agilent TS-8900 

Functional Test System

Site Preparation and 

Installation Guide

Содержание TS-8900

Страница 1: ...Agilent Technologies Agilent TS 8900 Functional Test System Site Preparation and Installation Guide...

Страница 2: ...find information about technical and professional services product support and equipment repair and service on the Web http www agilent com contacts Eng lish noscript html Double click the link to Te...

Страница 3: ...d Regulatory Markings 2 5 Declaration of Conformity 2 7 Electrostatic Discharge ESD Precautions 2 8 End of Life Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC 2 9 3 Site Preparati...

Страница 4: ...System Transportation Instructions 3 14 Ramp Requirements 3 14 Hallway and Door Width Requirements 3 14 If the System Cannot be Moved in the Crate 3 14 4 Installing The Keyboard Mouse and Printer Tool...

Страница 5: ...3 Figure 3 2 Recommended TS 8900 Functional Test System Layout overhead view 3 5 Figure 3 3 Rear View of The TS 8900 Functional Test System 3 6 Figure 3 4 E1135C Power Cord Installation 3 8 Figure 3...

Страница 6: ...vi TS 8900 Functional Test System Site Preparation and Installation Guide THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 7: ...d Regional Headquarters 1 3 2 Safety and Regulatory Information Table 2 1 Environment Requirements 2 3 Table 2 2 Safety Symbols and Regulatory Markings 2 5 Table 2 3 Suggested Anti Static Solutions fo...

Страница 8: ...viii TS 8900 Functional Test System Site Preparation and Installation Guide THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 9: ...te Preparation and Installation Guide First Edition April 2011 Agilent Technologies 1 Legal Information Warranty 1 2 Technology Licenses 1 2 Restricted Rights Legend 1 2 Service And Support 1 3 Agilen...

Страница 10: ...warranty terms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in acco...

Страница 11: ...d equipment repair and service on the Web http www agilent com Double click the link to Test Measurement Select your country from the drop down menus The Web page that appears next has contact informa...

Страница 12: ...nctional Test System Site Preparation and Installation Guide 1 Legal Information Manufacturing Address Agilent Technologies Microwave Products Malaysia Sdn Bhd Bayan Lepas Free Industrial Zone 11900 P...

Страница 13: ...afety Information 2 2 Safety Summary 2 2 Safety Notice 2 2 General 2 2 Environmental Conditions 2 3 Before Applying Power 2 4 Operator Safety Information 2 4 Safety Symbols and Regulatory Markings 2 5...

Страница 14: ...s of this product may be impaired if it is used in a manner not specified in the operation instructions CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice...

Страница 15: ...ucts that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by a qualified service personnel WARNING The protection provided by...

Страница 16: ...ard Verify there are multiple and sufficient protective means rated for the voltages you are applying to assure the operator will NOT come into contact with any energized conductor even if one of the...

Страница 17: ...ols and Regulatory Markings Safety symbols Warning risk of electric shock Warning hot surface Caution refer to accompanying documents Laser radiation symbol marked on products that have a laser output...

Страница 18: ...gistered trademark of the Spectrum Management Agency of Australia This signifies compliance with the Australian EMC Framework regulations under the terms of the Radio Communications Act of 1992 ISM 1A...

Страница 19: ...The Declaration of Conformity DoC for this product is available on the Agilent Technologies website You can search for the DoC by its product model or description at the following web address http re...

Страница 20: ...and or test disruption While not an exhaustive list of anti static precautions Table 2 3 shows suggestions to consider as you plan your system area ESD Symbol Caution Static Sensitive Electrostatic d...

Страница 21: ...e affixed product label see below indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE...

Страница 22: ...2 10 TS 8900 Functional Test System Site Preparation and Installation Guide 2 Safety and Regulatory Information THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 23: ...wer Requirements 3 7 Power Recommendations 3 7 Additional Power Information 3 9 Mains Disconnect Requirements 3 10 Disconnect Circuit Breaker Requirements 3 10 Mains Circuit Breaker Requirements 3 10...

Страница 24: ...irements Preparing Your Site for the System WARNING No operator serviceable parts inside Refer servicing to qualified personnel To prevent electrical shock do not remove instrument covers The protecti...

Страница 25: ...irements 3 TS 8900 Functional Test System Site Preparation and Installation Guide 3 3 Typical System Figure 3 1 shows a typical hardware configuration of the TS 8900 Functional Test system Figure 3 1...

Страница 26: ...Requirements System Dimensions Table 3 1 shows rack dimensions for the primary rack only Table 3 1 Primary Rack Dimensions Size No of Bays per Pallet Height Width Depth Estimated Weight 1 6m 1 1616mm...

Страница 27: ...s a recommended layout for a typical TS 8900 Functional Test System Allow 1 meter 3 3 feet of space behind the system for service WARNING The Remote ON Standby switch at the upper right hand corner of...

Страница 28: ...section describes the electrical power requirements of the Agilent TS 8900 Functional Test System using the Agilent E1135C Power Distribution Unit PDU It also describes how to connect AC mains power t...

Страница 29: ...ns Provide a separate AC mains for the system due to the current requirements of the system Use copper wire for the system drop between the AC source and system For Agilent E1135C PDU a jumper wire ma...

Страница 30: ...Requirements WARNING Electrical Shock Hazard Protection This is a Safety Class 1 Product provided with a protective earthing ground incorporated in the power cord The mains plug shall be inserted into...

Страница 31: ...or block and the ground connection to a terminal bolted to the chassis Power is connected to the mains disconnect switch and a ground terminal attached to the chassis For ease of installation in areas...

Страница 32: ...equirements The disconnect circuit breaker must be Rated for the maximum system amperes Approved for use in building installations in your locality Marked Mains Disconnect or the equivalent in your lo...

Страница 33: ...m Important recommendations about wiring Make certain that the wire used for the neutral is the same size as the hot leads or larger Do not rely on conduit for the ground always use at least one wire...

Страница 34: ...5 should be connected by a wire separate from the system AC power cord to the Protective Earth connection at the AC source where the system AC power cord is connected The wire must be the same wire s...

Страница 35: ...ntain proper airflow keep the area directly above the fans as well as the intake air louvers on the back clear for a minimum of 1 meter 3 3 feet Cleaning Instructions WARNING To prevent electrical sho...

Страница 36: ...hen evaluating hallways doors and elevators along the route the system must travel If the System Cannot be Moved in the Crate If obstacles or lack of space restrict moving the crated system remove the...

Страница 37: ...aration and Installation Guide First Edition April 2011 Agilent Technologies 4 Installing The Keyboard Mouse and Printer Tools Required 4 2 Installation Procedure 4 3 Printer Tray 4 3 Mouse Tray 4 4 P...

Страница 38: ...shelf mouse tray and printer tray onto the Test Rack how to connect the keyboard and mouse and how to connect an optional strip printer NOTE Four captive nuts are installed on the front of the test r...

Страница 39: ...Printer Tray Attach the printer tray to the keyboard shelf Make sure that the two hooks engage the shelf and the bottom of the tray is inserted into the tab under the keyboard shelf Figure 4 1 Attach...

Страница 40: ...tion Guide 4 Installing The Keyboard Mouse and Printer Mouse Tray Attach the mouse tray to the keyboard shelf Make sure that the two hooks engage the shelf and the bottom of the tray is inserted into...

Страница 41: ...rd Mouse and Printer 4 TS 8900 Functional Test System Site Preparation and Installation Guide 4 5 Palm Rest Install the plastic palm rest by slipping it into the sots in the keyboard shelf Figure 4 3...

Страница 42: ...les are labelled Keyboard and Mouse Slide the excess cabling into the slot in the keyboard shelf Figure 4 4 Connecting Keyboard and Mouse If you have an optional Strip Printer not provided by Agilent...

Отзывы: