Performance Specifications
108
Series N6700 User’s Guide
Performance Specifications
Agilent Models N6751A/N6752A and N6761A/N6762A
N6751A / N6752A
N6761A / N6762A
DC Output Ratings:
Voltage
50 V
50 V
Current (derated 1% per °C above 40°C)
5 A / 10A
1.5 A / 3 A
Power
50 W / 100 W
50 W / 100 W
Output Ripple and Noise (PARD):
(from 20 Hz – 20 MHz)
CV peak-to-peak
NOTE 1
6 mV
6 mV
CV rms
1 mV
1 mV
Load Effect (Regulation)
(for any output load change, with a maximum load-lead drop of 1V/lead)
Voltage
2 mV
0.5 mV
Current (@ 0 - 7 V)
(@ 0 - 50 V)
2 mA
2 mA
30
µ
A
NOTE 2
65
µ
A
Source Effect (Regulation):
Voltage
1 mV
0.5 mV
Current
1 mA
30
µ
A
Programming Accuracy:
(@ 23 °C
±
5 °C after 30 min. warm-up. Applies from min. to max. programming range)
Voltage high range
0.06% + 19 mV
0.016% + 6 mV
Voltage low range (
≤
5.5 V)
N/A
0.016% + 1.5 mV
Current high range
0.1% + 20 mA
0.04% + 200
µ
A
Current low range (
≤
100 mA, @ 0 - 7 V)
NOTE 2
(
≤
100 mA, @ 0 - 50 V)
N/A
N/A
0.04% + 15
µ
A
0.04% + 55
µ
A
Measurement Accuracy:
(at 23 °C
±
5 °C)
Voltage high range
0.05% + 20 mV
0.016% + 6 mV
Voltage low range (
≤
5.5 V)
N/A
0.016% + 1.5 mV
Current high range
0.1% + 4 mA
0.03% + 200
µ
A
Current low range (
≤
100 mA, @ 0 - 7 V)
NOTE 2
(
≤
100 mA, @ 0 - 50 V)
N/A
N/A
0.03% + 15
µ
A
NOTE 3
0.03% + 55
µ
A
Load Transient Recovery Time:
(time to recover to within the settling band following a load change
- from 60% to 100% and from 100% to 60% of full load for models N6751A & N6761A
- from 50% to 100% and from 100% to 50% of full load for models N6752A &N6762A.)
Voltage settling band
± 75 mV
NOTE 4
± 75 mV
Time
< 100
µ
s
< 100
µ
s
1
For typical values, refer to Supplemental Characteristics.
2
Requires a 3 minute wait if you have entered the 0 – 7 V range from a voltage greater than 7 V.
3
Applies when measuring 4096 data points (SENSe:SWEep:POINts = 4096).
4