Performance Tests
Equipment Required
Procedure
52/155 and 622 Mb/s Optical Output Checks
1
Press
<Menu>
, choose
Tx/Rx > Stored Settings
then press
<Select>
. Select
Default
then
Recall
.
2
Press
<Menu>
, choose
Tx/Rx > Transmitter Settings
then
press
<Select>
. Select the
Physical
tab. Set the
Signal Mode
to
SONET,
the
Signal Rate
to
OC1
and the
Wavelength
1310 nm
(or if this is not fitted, or already tested, select
1550 nm
). Ensure the
Laser
is set to
OFF
.
High Speed Optical
Oscilloscope
Agilent Infinium 86100A Mainframe
Agilent Infinium 86103A option 201, Optical
Plug-in
Agilent Infinium 86105A option 202, Optical
Plug-in
Optical Attenuator
Agilent 8156A
Optical Patch Cord(s)
Agilent PN 1005-0337
BNC(m) to SMA(f) Adapter
Agilent E9632A
SMA(m) to SMA(m) cable
Agilent PN 8120-4948
N O T E
This performance test uses the Infinium 86100A Optical Oscilloscope
(DCA) with appropriate Optical Plug-in modules and built-in filters. If a
different oscilloscope is used refer to the oscilloscope information for
Optical Eye Mask measurement.
The OTU-1 and OTU-2 pulse mask files may not be available on your
Oscilloscope. If required these can be obtained from the Agilent.com web
site at http://www.agilent.com/comms/omniberotn under the heading
“Software and Drivers”
To test the OC-1/STM-0 power level and eye mask
panther3_iv.book Page 82 Wednesday, January 15, 2003 12:03 PM
Содержание OmniBER J7230A
Страница 2: ...sdh_Lynx2 book Page 148 Wednesday April 17 2002 12 49 PM...
Страница 10: ...8 Installation and Verification Manual panther3_iv book Page 8 Wednesday January 15 2003 12 03 PM...
Страница 172: ...170 Installation and Verification Manual panther3_iv book Page 170 Wednesday January 15 2003 12 03 PM...
Страница 173: ...sdh_Lynx2 book Page 148 Wednesday April 17 2002 12 49 PM...