130
N9310A User’s Guide
6
Subsystem Command Reference
Pulse Modulation Subsystem
The phase modulation (
F
M) subsystem controls the settings
and parameters associated with phase modulated signal.
Pulse Modulation State
:PULM:STATe ON|OFF|1|0
:PULM:STATe?
This command toggles the pulse modulation state between
ON
and
OFF
.
The query returns the current pulse modulation state
.
Pulse Source
:PULM:SOURce INT|EXT
:PULM:SOURce?
This command sets the pulse source to either internal or
external source.
The query returns the current pulse modulation source.
Range
ON(1), OFF(0)
*RST value
OFF
Returned data
1, 0
Front panel access
Pulse > Pulse On/Off
Range
INT, EXT
*RST value
INT
Returned data
INT, EXT
Front panel access
Pulse > Pulse Source