The frequency range of sinusoidal interference is limited (see the technical
specifications).
One of four modes can be chosen for sinusoidal interference:
•
Common
: Requires that a differential data signal is generated and connected
to P1/P1 or P2/P2 of the Interference Channel.
In common mode, both components of the differential data signal are
amplitude-modulated with the same sinewave. This adds common mode noise.
•
Differential
: Requires that a differential data signal is generated and connected
to P1/P1 or P2/P2 of the Interference Channel.
In differential mode, both components of the differential data signal are
amplitude-modulated, one with the normal sinewave, the other with the
inverted sinewave. This adds differential noise.
•
Single-ended normal
: Modulates the data signal that is connected to P1 or P2
of the Interference Channel.
•
Single-ended complement
: Modulates the data signal that is connected to
P1 or P2 of the Interference Channel.
Jitter Tolerance Characterization
Jitter Tolerance Characterization - Concepts
During a jitter tolerance characterization test, jitter is applied sequentially at a
number of frequency points in the frequency range of interest.
The receiver checks for the onset of transmission errors and increments/
decrements the jitter amplitude using a control algorithm, re-testing for errors at
one frequency point until the target BER threshold is found. This is repeated for
each subsequent jitter frequency step to provide a plot of the DUT tolerance.
Jitter Tolerance Tests
8
Agilent J-BERT N4903B High-Performance Serial BERT
433
Frequency
Mode
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...