How to Improve the Output Levels Display
You can change the display of an existing measurement, for example, if you wish
to see more details to investigate the graph.
This can be done on the
Graph
tab of the
Properties
dialog box:
1
Press the
Properties
button. If you have a mouse connected to your Serial
BERT, you can also click the right mouse button on the graph and select
Properties
from the context menu.
2
Switch to the
Graph
tab.
3
As an example, select
Show Measured Points
.
With this option selected, all measured points are indicated in the graph with
small squares.
The headline of the graph tells the number of data points included in the display:
101. This corresponds to the chosen threshold resolution of 100 steps per Volt.
With this number of measured points, you do not get very precise results during
the measurement, but it is quickly finished.
Depending on your personal needs, you can trade measurement precision
against test time.
4
Several more options are provided on the
Graph
tab for you to adjust the display
as you want. For instance, you can use markers for analyzing the graph or open
a zoom window for viewing the details. To find more information, refer to
.
6
Advanced Analysis
268
Agilent J-BERT N4903B High-Performance Serial BERT
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...