Sync Now
Click this button to manually start a pattern synchronization. See
Synchronization Should You Use?” on page 208
should use this function.
Note that this button is not available in bit recovery mode.
0/1 THReshold Center
Starts an auto-search function that sets the 0/1 threshold to the optimum point of
the incoming data eye on the vertical voltage axis without changing the data input
delay. This function can be used for determining the optimum 0/1 threshold for
asymmetric data eyes, or for patterns with an unequal mark density.
The status message bar will indicate if this function is unsuccessful. This function
clears the
Avg. 0/1 Threshold
checkbox.
N O T E
This function uses the alignment
BER Threshold to determine the top and bottom
eye edges.
Data Center
This button starts an auto-search function that aligns the data signal with the clock
signal so that the error detector samples at the optimum point of the data eye in
the time axis. This automatically compensates for delays in the clock/data paths,
preventing unnecessary errors. The 0/1 decision threshold is not changed. The
status message bar will indicate if this function is unsuccessful.
N O T E
Ensure that the received clock frequency is stable before using
Data Center.
T I P
The clock/data alignment process time is pattern dependent, and with some large
user patterns the alignment can take several minutes. If you encounter such a long
time with a user pattern, it may be possible to first perform clock/data alignment
on a pure PRBS pattern. This generally does not affect alignment accuracy, and can
minimize measurement time.
This tip does not apply in cases of severe pattern dependent jitter or with devices
that do not work with PRBS patterns.
N O T E
This function uses the alignment
BER threshold to determine the left and right eye
edges.
5
Setting up the Error Detector
200
Agilent J-BERT N4903B High-Performance Serial BERT
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...