Alternate Pattern Trigger Level
N O T E
This option applies for alternating patterns only.
Select this option to set the trigger level high whenever alternate pattern B is sent.
The trigger output for 1024-bit patterns looks as follows:
Data Out
A
A
B
A
B
B
A
Trigger Out
N O T E
This pattern must be at least 1024 bits long.
Alternate Pattern Trigger Pulse
Select this option to send a trigger pulse whenever the pattern being sent changes
(A to B or vice versa). For patterns with a length divisible by 512, there is one trigger
pulse sent for every pattern repetition.
Data Out
Trigger Out
A
B
A
B
B
If the length of the pattern is not divisible by 512, a trigger is sent whenever the
pattern reaches a 512-bit RAM boundary.
Sequence Trigger
This checkbox becomes available after a user-defined sequence has been
downloaded to the pattern generator.
Click this checkbox to switch the Trigger/Ref Clock Out port to
Sequence
mode.
In
Sequence
mode, the Trigger/Ref Clock Out can generate a spike whenever the
execution of a block starts or restarts. Whether that happens for a particular block
or not is defined for each block individually in the SequenceExpression. See also
“Sequence Block Parameters” on page 102
.
Setting up the Pattern Generator
4
Agilent J-BERT N4903B High-Performance Serial BERT
147
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...