Fine Adjust
Fine Adjust allows you to tweak the response of the CDR according to
transition density changes. This control can be used to reduce jitter in
pattern with high changes in transition density.
Peaking
The drop down list provides a maximum of three peaking values. If a
standard from the preset list is selected, this field is preset. A low value
reduces the peaking near the loop bandwidth while, a higher value
improves the SSC response.
Auto Threshold
If the
Auto Threshold
option is selected, the Serial BERT continuously
analyzes the incoming data stream to detect the voltage level that is
optimal for the derivation of the clock signal.
This function is recommended for all applications where a valid data
stream is continuously arriving at the error detector.
For measurements with partly invalid data, such as burst tests, this
function may cause a clock loss. In such cases, deactivate
Auto
Threshold
and
•
enter a fixed voltage level manually, or
•
press the
Measure
button to measure the voltage level of the incoming
signal while a burst signal is applied.
Once the level is defined, it remains fixed for the following
measurements.
Note that the entered voltage level has to be within the input range of
the error detector. If the value lies outside this range, the change is
rejected and an error message is displayed.
CDR Spread Spectrum Clocking
The CDR Spread Spectrum Clocking is available only with the option
CTR / upgrade UTR.
Setting up the Error Detector
4
Agilent J-BERT N4903 High-Performance Serial BERT
125
Содержание J-BERT N4903
Страница 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Страница 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Страница 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Страница 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Страница 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Страница 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Страница 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...