Agilent Ininiium 9000 Series Oscilloscopes

Engineered for broadest measurement capability

Data Sheet

Содержание Infiniium DSO9064A

Страница 1: ...Agilent Ininiium 9000 Series Oscilloscopes Engineered for broadest measurement capability Data Sheet ...

Страница 2: ...s That s why we designed our new Ininiium 9000 Series oscilloscope to meet a full range of needs First we built in the powerful features you d expect in any Ininiium scope Then we engineered the scope for the broadest measurement capability so it would be the most indispensable tool in your arsenal Model Analog bandwidth Analog sample rate 4 channel 2 channel Standard memory 4 channel 2 channel Sc...

Страница 3: ...and compliance application software Need accurate answers to your measurement questions The Ininiium 9000 Series offers the largest range of application speciic software for debug analysis and compliance test ing Which application is right for you Take a look at the possibilities on pages 7 12 It s sized to fit your environment Limited bench space It has a small footprint and thin proile Height 12...

Страница 4: ...g boxes with descriptive graphics Drag and drop measurements It s simple drag an icon from the measure ment bar and drop it on the cycle you want to measure You can make up to ten measure ments on your waveforms All of the measure ments appear at the bottom of the display with statistics and are color coded to the channel you are measuring High performance scope channels ensure superior viewing of...

Страница 5: ...g Windows View buses as waveforms or easily follow events in the listing window expandable to the entire display A blue tracking marker provides time correlation between waveform and listing displays MSO models add 16 high speed timing channels with standard 128 Mpts digital memory allowing you to retain fast 2 GSa s sample rates over long periods of time Use the timing channels to evaluate contro...

Страница 6: ...r information using the time correlated tracking marker Display protocol content using waveform symbols and the industry s first multi tab protocol viewer The packets tab shows a high level view of the packet over time Protocol level triggering makes it easy to isolate events with pinpoint accuracy Use any combination of analog or digital channels for serial protocol decode with up to four buses d...

Страница 7: ...d view both protocol layer information and physical layer signal characteristics for CAN LIN and FlexRay buses Numerical decode values are automatically displayed and synchronized below the captured signal or seen in protocol viewer Hardware based triggering for CAN and LIN means triggering reliably even on the most infrequent events FlexRay uses software based protocol triggering This application...

Страница 8: ...agilent com find N8802A SATA triggering and decode N8801A or option 038 on new scope purchases Trigger on and view both protocol layer information and physical layer signal characteristics for SATA 1 1 5 GB s Numerical decode values are automatically displayed and synchronized below the capture signal or seen in protocol viewer This application enables software based protocol triggering This appli...

Страница 9: ...cation is supported on all models However the DDR technology you are using may dictate the minimal bandwidth required for your scope For more information www agilent com find 9000_DDR Ethernet and Energy Efficient Ethernet compliance testing N5392A and N5392B Perform a wide range of electrical tests for 10 100 and 1000 Base T systems An N5395C test ixture and N5396A jitter test cable speed complia...

Страница 10: ...to EZJIT Plus order N5401A EZJIT Plus adds additional compliance views and an expanded measurement setup wizard to simplify and automate RJ DJ separation for testing against industry standards This application is supported on all models For more information www agilent com find EZJITPlus Identify signal integrity issues with InfiniiScan Zone Qualify triggering Conduct jitter analysis Analyze jitte...

Страница 11: ...tration out of communications testing and prove your designs conform to industry standards with the communication mask test kit option The kit comes with a set of electrical communication adapters to ensure convenient reliable and accurate connections to your device under test The kit includes more than 20 industry standard ANSI T1 102 ITU T G 703 and IEEE 802 3 communication signal mask templates...

Страница 12: ...ments FPGA dynamic probe application N5397A or Option 016 on new scope purchases Agilent s MSO FPGA dynamic probe provides internal FPGA visibility and quick instrument setup using an innovative core assisted debug approach Measurement tasks that previously took hours can be done in seconds with a few mouse clicks This application is supported on all MSO models For more information www agilent com...

Страница 13: ...Biggest display plus thin depth 9000 Series 9000 H Series 90000 Series 90000 X Series 90000 Q Series Bandwidth Up to 4 GHz Up to 2 GHz Up to 13 GHz Up to 33 GHz Up to 63 GHz 50 Ω 1 MΩ inputs 1 M Ω with adapter 1 M Ω with adapter 1 M Ω with adapter MSO models Max 2 channel 4 channel sample rate 20 GSa s 10 GSa s 10 GSa s 10 GSa s 40 GSa s 40 GSa s 80 GSa s 40 GSa s 160 GSa s 80 GSa s GPIB N4865A GP...

Страница 14: ...te four analog scope channels with 16 digital channels Comprehensive built in information system gives you fast answers to your questions The task oriented setup guide provides step by step instructions for several measurement procedures XGA and DVI video output port lets you connect to an external monitor Standard USB and LAN ports provide PC and printer connectivity Trig in out ports provide an ...

Страница 15: ...r controls for the best display while optimizing memory Digital channel button provides quick setup access Serial decode button enables quick setup access Dedicated per channel front panel controls make it easy to access the vertical and horizontal scaling and offset Quick access to fine vernier control by pressing the horizon tal and vertical sensitivity knobs Accessory pouch detaches easily Auto...

Страница 16: ...ries probes Agilent offers an innovative family of probes that are engineered for signal access and measurement accuracy Whether you re looking for simple passive probes the high bandwidth and low loading of an active probe or specialty probes for current or high voltage we can meet your needs Our inno vative accessories allow reliable connection to challenging DSO MSO9404A 1132A IniniiMax 5 GHz p...

Страница 17: ...5 C from cal temp Maximum input voltage1 1 MΩ 150V RMS or DC CAT I 250 V DC AC in AC coupling 50 Ω 5 Vrms Offset range Vertical sensitivity Available offset 1 MΩ 1 mV to 10 mV div 2 V 10 mV to 20 mV div 5 V 20 mV to 100 mV div 10 V 100 mV to 1 V div 20 V 1 V to 5 V div 100 V 50 Ω 12 div or 4V whichever is smallest 1 Denotes warranted specifications all others are typical Specifications are valid a...

Страница 18: ...0 mV 100 mV 200 mV 5 00mV 1V 2V 5V Vertical digital channels On all MSO Models Input channels 16 digital channels Threshold groupings 16 digital channels Pod 2 D15 D8 Threshold selections TTL 1 4V CMOS 5 0V 3 3V 2 5V ECL 1 3V PECL 3 7V user defined 8 00 V in 100 mV increments Maximum input voltage 40 V peak CAT I Threshold accuracy 100 mV 3 of threshold setting Input dynamic range 10 V about thres...

Страница 19: ...libration temperature 2 Noise is the displayed noise floor SlewRate is the displayed slew rate of the signal at the threshold crossings Sample rate max sin x x interpolation enabled 3 Measurement threshold fixed voltage at 50 level 4 Time ranges 10 μs 5 Values represent time error between two edges on a single channel Standard deviation value refers to the standard deviation of 256 consecutive mea...

Страница 20: ...64 32 Mpts with sampling 2 GSa s single repetitive mode Minimum width glitch detection 2 ns Trigger scope channels Trigger sources Channel 1 channel 2 channel 3 channel 4 aux and line Sensitivity 1 MΩ input edge trigger DC to 500 MHz 0 6 div 50 Ω DC to 2 GHz 0 5 div 2 GHz to 4 GHz 1 0 div Auxiliary DC to 700 MHz 300 mVp p Trigger level range 4 div from center screen 50 Ω Channel 1 2 3 4 8 div from...

Страница 21: ...urement values for the displayed automatic measurements Histograms scope channels Source Waveform or measurement histogram on measurement requires EZJIT EZJIT or EZJIT Complete option Orientation Vertical for timing and jitter measurements or horizontal noise and amplitude change modes regions are defined using waveform markers Measurements Mean standard deviation mean 1 2 and 3 sigma median mode ...

Страница 22: ...tectable pulse width 500 ps for analog channels 1 ns for digital channels Pulse width range settings 700 ps to 10 s for analog channels 2 ns to 10 s for digital channels Runt analog Triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Runt settings equal pulse width settings Timeout analog and digital Trigger when a channel stays high...

Страница 23: ...mouse and compact keyboard supplied All Infiniium models support any Windows compatible input device with a PS 2 or USB interface File types Waveforms Compressed internal format wfm comma separated values csv hdf5 bin tab separated values tsv ability to save osc composite including both setup and waveform and Y value files txt Images BMP TIFF GIF PNG or JPEG I O ports LAN RJ 45 connector supports ...

Страница 24: ...es per axis 0 3 g rms Non operating Random vibration 5 500 Hz 10 minutes per axis 2 41 g rms resonant search 5 500 Hz swept sine 1 octave minute sweep rate 0 75 g 5 minute resonant dwell at 4 resonances per axis Power 100 120 V 10 50 60 400 Hz 100 240 V 10 50 60 Hz Max power dissipated 375 W Typical operator noise 30 dB at front of instrument Weight Net 11 8 kg 26 lbs Shipping 17 8 kg 39 lbs Dimen...

Страница 25: ...4A 1 GHz 10 GSa s 20 GSa s 20 Mpts 40 Mpts 4 16 DSO9254A 2 5 GHz 10 GSa s 20 GSa s 20 Mpts 40 Mpts 4 MSO9254A 2 5 GHz 10 GSa s 20 GSa s 20 Mpts 40 Mpts 4 16 DSO9404A 4 GHz 10 GSa s 20 GSa s 20 Mpts 40 Mpts 4 MSO9404A 4 GHz 10 GSa s 20 GSa s 20 Mpts 40 Mpts 4 16 In 2 channel mode maximum sample rate and memory depth double How to configure an Infiniium 9000 Series 1 Choose needed bandwidth 2 Choose...

Страница 26: ... U1882A Xilinx FPGA dynamic probe 016 N5397A Altera FPGA dynamic probe 017 N5433A RS 232 SPI and I2 C triggering and decode bundle 018 N8800B MIPI D Phy Triggering and decode 019 N8802A 036 Ethernet compliance 021 N5392A 008 USB2 0 compliance 029 N5416A 017 DDR1 and LPDDR compliance 031 U7233A 021 DDR2 and LPDDR2 compliance 032 N5413B 016 DDR3 compliance 033 U7231A 020 MIPI D Phy compliance 035 U7...

Страница 27: ... existing DSO to an MSO model in 5 minutes The upgrade kit turns on all MSO capability and includes an MSO cable 16 channel lead set with grabbers an MSO enabled sticker and a digital analog deskew fixture Additional acquisition memory N2900A or options 50 100 200 and 500 on new scope purchase Increase memory depth to capture longer time periods and maintain faster speeds Memory depth doubles in 2...

Страница 28: ...lpartners Get the best of both worlds Agilent s measurement expertise and product breadth combined with channel partner convenience www agilent com www agilent com ind 9000 For more information on Agilent Technologies products applications or services please contact your local Agilent office The complete list is available at www agilent com find contactus Americas Canada 877 894 4414 Brazil 11 419...