background image

Agilent Ininiium 90000 Series Oscilloscopes

Engineered for unmatched real-time measurement accuracy

Data Sheet

Содержание Infiniium 90254A

Страница 1: ...Agilent Ininiium 90000 Series Oscilloscopes Engineered for unmatched real time measurement accuracy Data Sheet...

Страница 2: ...GSa s on 4 ch 20 Mpts on 4 ch 1 Gpts on 4 ch 1 15 mVrms 90604A 6 GHz 20 GSa s on 4 ch 20 Mpts on 4 ch 1 Gpts on 4 ch 0 98 mVrms 90404A 4 GHz 20 GSa s on 4 ch 20 Mpts on 4 ch 1 Gpts on 4 ch 0 79 mVrms...

Страница 3: ...y s lowest noise floor Leveraging the company expertise in RF design Agilent has invested in key technology blocks like our proprietary Faraday caged front end to significantly reduce our inherent sco...

Страница 4: ...s sit on the industry standards committees and help define the compliance requirements They make sure our tools deliver exactly to the standards You get the benefit of years of training and experience...

Страница 5: ...apabilities like Zone Qualify and Generic Serial triggering possible Rapidly automate any scope measurement using the N5467A User Defined Application and have it appear seamlessly in your scope s menu...

Страница 6: ...ents A resolution bandwidth of 6 kHz is supported with the standard 10 Megabytes of acquisition memory at the maximum sample rate of 40 GSa s With optional acquisition memory installed resolution band...

Страница 7: ...to simplify and automate RJ DJ separation for testing against industry standards This application is supported on all models and is standard on DSA models For more information www agilent com find EZJ...

Страница 8: ...e diagrams The SDA package also includes software based bit level triggering and decode for 8B 10B This application is supported on all models and comes standard on DSA models For more information www...

Страница 9: ...PI Control your applications remotely InfiniiSim Waveform Transformation and De embedding Toolset Basic N5465A 001 or option 13 on new scope purchases Advanced N5465A 002 or Option 14 on new scope pur...

Страница 10: ...s graphically visualize signals in 2 D or 3 D plots automate measurements or build test applications Purchase MATLAB with your Agilent 90000 Series oscilloscope to ensure version compatibility and so...

Страница 11: ...oscilloscope based protocol analyzer with time correlated views of physical layer and transaction layer errors The multi tab protocol viewer includes correlation between the waveforms and the selected...

Страница 12: ...and detail information Powerful time correlated views of waveform symbol character link and transaction layer packet data down to the bit level make it easy to isolate communication faults to logic or...

Страница 13: ...CI EXPRESS Electrical Performance Validation and Compliance Software N5393B or Option 022 on new scope purchases Provides fast and easy way to verify and debug your PCI EXPRESS designs Allows you to a...

Страница 14: ...tion 038 on new scope purchases Rapidly validate and debug your SATA 1 5Gb s Gen 1 3 0 Gb s Gen2 and 6 0 Gb s Gen3 silicon host bus adapter port multiplier high density disk drive solid state disk dri...

Страница 15: ...w agilent com find N5431A Perform automated testing and margin analysis for XAUI and XAUI derived specifications DVI Electrical Performance Validation Compliance Software N5394A or Option 034 on new s...

Страница 16: ...ww agilent com find USB3 Validate and debug your USB 3 0 silicon host hub or device DDR1 and LPDDR DDR2 LPDDR2 DDR3 DDR4 and GDDR5 compliance testing U7233A N5413B U7231B N6462A U7245A or Options 031...

Страница 17: ...GHz 600 MHz 1 GHz 2 5 GHz 4 GHz 2 5 GHz 4 GHz 6 to 16 GHz 6 GHz 8 GHz 12 GHz 13 GHz 13 GHz 16 GHz 20 to 63 GHz 20 GHz 25 GHz 33 GHz 20 GHz 25 GHz 33 GHz 50 GHz 63 GHz Max upgradable bandwidth 4 GHz 13...

Страница 18: ...t the bottom left of the Infiniium screen to minimize the status and scales tab for full screen viewing Maximize your viewing needs Ever wanted to change the scale or offset of a function or waveform...

Страница 19: ...d marker knob provides quick access to your marker control Quick access to fine vernier control by pressing the horizontal and vertical sensitivity knobs Increase your productivity with a familiar Inf...

Страница 20: ...xible connectivity solutions for today s high density ICs and circuit boards InfiniiMax probes have fully characterized performance for all of their various probe heads This includes Swept frequency r...

Страница 21: ...st efficient solution and wider dynamic range N5450B InfiniiMax extreme temperature extension cable provides extra reach into environmental chambers N5380B 13 GHz high bandwidth differential SMA probe...

Страница 22: ...mic range 4 div from center screen DC voltage measurement accuracy 1 Dual cursor DC gain accuracy resolution Single cursor DC gain accuracy offset accuracy resolution 2 RMS noise floor scope only Volt...

Страница 23: ...time Main timebase delay range 200 s to 200 s real time 25 s to 200 s equivalent time Zoom timebase range 1 ps div to current main time scale setting Channel deskew 25 s range 100 fs resolution Time...

Страница 24: ...Sampling modes Real time Real time with averaging Real time with peak detect Real time with hi resolution Equivalent time Segmented memory Successive single shot acquisitions Selectable from 2 to 6553...

Страница 25: ...nput will generate the trigger The trigger is qualified by an edge After a specified delay between 1 to 16 000 000 rising or falling edges another rising or falling edge on any one selected input will...

Страница 26: ...tion occurs Actions include e mail on trigger and execute multipurpose user setting Trigger shortcuts Provides easy shortcuts to all trigger features Software trigger requires InfiniiScan event identi...

Страница 27: ...displayed automatic measurements Histograms Source Orientation Measurements Waveform or measurement12 Vertical for timing and jitter measurements or horizontal noise and amplitude change modes region...

Страница 28: ...vertical resolution Connected dots dots infinite persistence color graded infinite persistence Includes up to 256 levels of intensity graded waveforms Waveform update rate Maximum waveform update 400...

Страница 29: ...lbs Shipping 27 4 kg 60 lbs Dimensions excluding handle Height 283 mm 11 13 inch Width 432 mm 17 02 inch Depth 506 mm 19 91 inch Safety Meets IEC 61010 1 A2 CSA certified to C22 2 No 1010 1 self certi...

Страница 30: ...fferential mode resistance 50 k 2 Single ended mode resistance 25 k 2 Input dynamic range 3 3 V peak to peak 1 65 V Input common mode range 6 75 V peak to peak dc to 100 Hz 1 25 V peak to peak 100 Hz...

Страница 31: ...to 100 Hz 1 25 V peak to peak 100 Hz Maximum signal slew rate 18 V ns when probing a single ended signal 30 V ns when probing a differential signal DC attenuation 10 1 3 before calibration on oscillos...

Страница 32: ...ption 801 Additional removable solid state drive for 90000 Series with Windows 7 DSO90000A 805 GPIB Card interface DSO90000A 807 1 M ohm adapter with a 500 MHz passive probe DSO90000A 820 DVD RW DSO90...

Страница 33: ...ompliance software 022 N5393B PCI EXPRESS electrical performance validations and compliance software 023 N5399A HDMI electrical performance validation and compliance software 024 N5409A Fully buffered...

Страница 34: ...5472A AFTER PURCHASE 10M TO 20M MEMORY UPGRADE N5472B AFTER PURCHASE 20M TO 50M MEMORY UPGRADE N5472C AFTER PURCHASE 50M TO 100M MEMORY UPGRADE N5472D AFTER PURCHASE 100M TO 200M MEMORY UPGRADE N5472E...

Страница 35: ...35 Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to 90 GHz Industry leading specs Powerful applications...

Страница 36: ...accurate measurements www agilent com quality Agilent Electronic Measurement Group DEKRA Certified ISO 9001 2008 Quality Management System Agilent Channel Partners www agilent com find channelpartners...

Отзывы: