Options UN8 and 202
Trailing Broadcast Bit (B2) Field
TETRA - Downlink Continuous Normal Timeslot
[:SOURce]:RADio:TETRa:SLOT[1]|2|3|4:DCNormal:B2 <16-bit value>
[:SOURce]:RADio:TETRa:SLOT[1]|2|3|4:DCNormal:B2?
This command sets the last 16 broadcast bits for the selected downlink continuous normal
timeslot.
Range: 0000 to 1FFF
*RST value: 0000 (hexadecimal)
TETRA - Downlink Discontinuous Normal Timeslot
[:SOURce]:RADio:TETRa:SLOT[1]|2|3|4:DDNormal:B2 <16-bit value>
[:SOURce]:RADio:TETRa:SLOT[1]|2|3|4:DDNormal:B2?
This command sets the last 16 broadcast bits for the selected downlink continuous normal
timeslot.
Range: 0000 to 1FFF
*RST value: 0000 (hexadecimal)
Training Sequence Field
EDGE/GSM - Normal Timeslot
[:SOURce]:RADio:EDGE:SLOT0|[1]|2|3|4|5|6|7:NORMal:TSEQuence TSC0|TSC1|
TSC2|TSC3|TSC4|TSC5|TSC6|TSC7|<78 bit_pattern>
[:SOURce]:RADio:EDGE:SLOT0|[1]|2|3|4|5|6|7:NORMal:TSEQuence?
[:SOURce]:RADio:GSM:SLOT0|[1]|2|3|4|5|6|7:NORMal:TSEQuence
TSC0|TSC1|TSC2|TSC3|TSC4|TSC5|TSC6|TSC7|<bit_pattern>
[:SOURce]:RADio:GSM:SLOT0|[1]|2|3|4|5|6|7:NORMal:TSEQuence?
For EDGE, this command enables you to set the 78-bit training sequence code for a normal
timeslot to one of eight values or to create a custom value. The default hexadecimal values
for the eight training sequence codes are listed below:
TSC0
3F3F9E49FFF3FF3F9E49
TSC1
3F3C9E49E493FF3C9E49
TSC2
39FFF24F24F3F9FFF24F
TSC3
39FF924F279FF9FF924F
TSC4
3FE4F3C93F9FFFE4F3C9
TSC5
39FC93CF27FFF9FC93CF
TSC6
0F3F9249E4FFCF3F9249
TSC7
093C927FE7F3C93C927F