Real-Time I/Q Baseband Generator User’s and Programming Guide
3-97
ESG Family Signal Generators
Softkey Reference
Options UN8 and 202
F
NADC:
Mode
>
TDMA
>
NADC
>
Data Format Pattern Framed
>
Configure Timeslots
>
Configure Up TCH
>
Data
>
FIX4
FIX4
is also located in the Configure Down Custom and Configure Up
Custom menus, and in the Data menu found in the Configure Down
TCH menu.
PDC:
Mode
>
TDMA
>
PDC
>
Data Format Pattern Framed
>
Configure Timeslots
>
Configure Up TCH
>
TCH
>
FIX4
FIX4
is also located in the Configure Down Custom and Configure Up
Custom menus, and in the TCH menu found in the Configure Down
TCH menu.
PHS:
Mode
>
TDMA
>
PHS
>
Data Format Pattern Framed
>
Configure Timeslots
>
Configure TCH
>
TCH
>
FIX4
FIX4
is also located in the Data menu found in the uplink Configure
TCH menu, and in the downlink and uplink Configure Custom
menus.
TETRA:
Mode
>
TDMA
>
TETRA
>
Data Format Pattern Framed
>
Configure Timeslots
>
Configure Up Normal
>
Data
>
FIX4
FIX4
is also located in the uplink and downlink Configure Custom
menus, and i the Data menus found in every other TETRA Configure
Timeslots menu.
Frame Repeat Single Cont
Press this softkey to toggle between a single output of framed data and
continuous transmission of frames. Selecting
Single
outputs the
following sequences:
• 4-Bit Patterns (FIX4) - A single frame is generated. The 4-bit pattern
repeats until the data fields are completely filled. Each trigger
transmits the same frame.
• Other Patterns (fixed patterns of equal quantities of ones and zeroes)
- A single frame is generated. The selected pattern repeats until the
data fields are completely filled. Each trigger transmits the same
frame.
• PN9 - A single frame is generated. The data fields are filled with the
leading bits of the PN9 sequence. A trigger causes the frame to be
transmitted. The data fields of this frame are then filled sequentially
with the next series of PN9 data bits. A trigger causes the frame to
be transmitted. This process continues, transmitting the entire PN9
sequence frame by frame. The last bit of the PN9 sequence in a data
field is immediately followed by the first bit of a second PN9
sequence.