338
Chapter 5
Language Reference
UNIT Subsystem
UNIT Subsystem
Select Power Units of Measure
:UNIT:POWer DBM|DBMV|DBUV|DBUA|V|W|A
:UNIT:POWer?
Specifies amplitude units for the input, output and display.
Factory Preset
and *RST:
dBm in log amplitude scale
volts in linear amplitude scale
History:
Ampere and decibel microampere units are available only with
instruments having firmware revision A.06.00 and later.
Front Panel
Access:
AMPLITUDE/Y Scale, Amptd Units
AMPLITUDE/Y Scale, Amptd Units, dBm
AMPLITUDE/Y Scale, Amptd Units, dBmV
AMPLITUDE/Y Scale, Amptd Units, dB
µ
V
AMPLITUDE/Y Scale, Amptd Units, Volts
AMPLITUDE/Y Scale, Amptd Units, Watts
AMPLITUDE/Y Scale, Amptd Units, Amps
AMPLITUDE/Y Scale, Amptd Units, dB
µ
A