![Agilent Technologies E4428C Скачать руководство пользователя страница 131](http://html.mh-extra.com/html/agilent-technologies/e4428c/e4428c_user-manual_2867497131.webp)
Chapter 4
107
Basic Digital Operation
Using the Dual ARB Waveform Player
Creating Waveform Segments
There are two ways to provide waveform segments for use by the waveform sequencer. You can either
download a waveform via the remote interface, or generate a waveform using one of the Arb modulation
formats. For information on downloading waveforms via the remote interface, see the
E4428C/38C ESG
Signal Generator Programming Guide
.
The following procedure describes how to create waveform segments using IS-95A CDMA waveforms. In
this procedure, you generate two IS-95A CDMA waveforms, a predefined 64 channel forward CDMA state
and a predefined 9 channel forward CDMA state. After the two waveform segments are named and stored in
memory, they are used to build a waveform sequence in the procedure,
“Creating a Waveform Sequence” on
1. Generate the first waveform:
a. Press
Preset
.
b. Press
Mode
>
CDMA
>
Arb IS-95A
.
c. Press
Setup Select
>
64 Ch Fwd
.
d. Press
CDMA Off On
until On is highlighted.
This generates a waveform named
AUTOGEN_WAVEFORM
with the predefined 64 channel forward
link CDMA configuration. The 64 channel forward link
AUTOGEN_WAVEFORM
is stored in volatile
waveform memory (WFM1). During waveform generation, the CDMA and I/Q annunciators are
shown on the ESG’s front-panel display.
e. Press
CDMA Off On
until Off is highlighted.
The
AUTOGEN_WAVEFORM
file is in use while the ARB modulation format is on; preventing you
from performing the modifications to the file as required in the following steps. When the
modulation format is turned off the
AUTOGEN_WAVEFORM
file remains in WFM1 and can be
modified and saved using a different file name.
2. Create the first waveform segment.
The
AUTOGEN_WAVEFORM
, created in the previous step, will be renamed and become the first waveform
segment.
a. Press
Mode
>
Dual ARB
>
Waveform Segments
>
Load Store
to Store.
b. Highlight the default
AUTOGEN_WAVEFORM
file using the front-panel arrow keys.
c. Press
Rename Segment
>
Editing Keys
>
Clear Text
.
d. Enter a file name (for example,
FWDCH_64
), and press
Enter
>
Store Segment To NVWFM Memory
.
This renames the waveform segment, and stores a copy in non-volatile memory (NVWFM).
NOTE
Because there can be only one
AUTOGEN_WAVEFORM
waveform in WFM1 at any given
time, you must rename this file to clear the way for a second waveform.
Содержание E4428C
Страница 22: ...Contents xxii ...
Страница 107: ...Chapter 3 83 Basic Operation Using Security Functions Figure 3 6 ESG Screen with Secure Display Activated ...
Страница 182: ...158 Chapter 4 Basic Digital Operation Using Waveform Clipping Figure 4 22 Rectangular Clipping ...
Страница 183: ...Chapter 4 159 Basic Digital Operation Using Waveform Clipping Figure 4 23 Reduction of Peak to Average Power ...
Страница 224: ...200 Chapter 4 Basic Digital Operation Creating and Using Bit Files ...
Страница 228: ...204 Chapter 5 AWGN Waveform Generator Configuring the AWGN Generator ...
Страница 229: ...205 6 Analog Modulation ...
Страница 276: ...252 Chapter 7 Digital Signal Interface Module Operating the N5102A Module in Input Mode ...
Страница 286: ...262 Chapter 8 Bluetooth Signals Turning On a Bluetooth Signal ...
Страница 287: ...263 9 BERT This feature is available only in E4438C ESG Vector Signal Generators with Option 001 601or 002 602 ...
Страница 330: ...306 Chapter 9 BERT Verifying BERT Operation ...
Страница 366: ...342 Chapter 10 CDMA Digital Modulation IS 95A Modulation ...
Страница 394: ...370 Chapter 12 Multitone Waveform Generator Applying Changes to an Active Multitone Signal ...
Страница 454: ...430 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Concepts Figure 15 9 Uplink Channel Structure ...
Страница 468: ...444 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Frame Structures ...
Страница 667: ...643 18 Troubleshooting ...
Страница 700: ...Index 676 Index ...