94
Chapter 5
Troubleshooting
Troubleshooting Client Connections
Troubleshooting Client Connections
This section gives guidelines to troubleshoot client connections to the E2050
LAN/GPIB Gateway, including:
n
Client Connection Problems
n
Client Run-time Errors
Client Connection Problems
Even if the E2050 LAN/GPIB Gateway has been successfully configured
and the configuration has been verified, individual clients may still have
problems getting a connection to the Gateway.
1
The first step is to verify that the client system has network access
to the Gateway. Use the
ping
command, as follows:
n
For a Windows 95/98/Me/2000/NT client system, type:
ping
hostname
(or)
IP_address
Enter
.
For example:
>ping E2050.agilent.com
Pinging E2050.agilent.com[128.10.0.3] with 32 bytes of
data:
Reply from 128.10.0.3:bytes=32 time=10ms TTL=255
Reply from 128.10.0.3:bytes=32 time=10ms TTL=255
Reply from 128.10.0.3:bytes=32 time=10ms TTL=255
Reply from 128.10.0.3:bytes=32 time=10ms TTL=225
Each line after the
Pinging
line is an example of a packet
successfully reaching the Gateway from the client system.
However, if
ping
is unable to reach the host, a message similar
to the following is displayed:
Pinging E2050.agilent.com[128.10.0.3] with 32 bytes of
data:
Request timed out.
Request timed out.
Request timed out.
Содержание E2050
Страница 1: ...Agilent E2050 LAN GPIB Gateway Installation and Configuration Guide ...
Страница 2: ......
Страница 10: ...10 ...
Страница 11: ...11 1 Introduction ...
Страница 23: ...23 2 Installation ...
Страница 32: ...32 Chapter 2 Installation Installing the Hardware Notes ...
Страница 33: ...33 3 Configuration ...
Страница 63: ...63 4 Administration ...
Страница 80: ...80 Chapter 4 Administration Configuring the Gateway Notes ...
Страница 81: ...81 5 Troubleshooting ...
Страница 99: ...99 A Specifications ...
Страница 102: ...102 Specifications Specifications Notes ...
Страница 103: ...103 Glossary ...
Страница 111: ...Part Number E2050 90003 Printed in U S A E0701 E2050 90003 ...