Multimeter Command Reference
95
[:VOLTage[:DC]]:RATio
CONFigure[:VOLTage[:DC]]:RATio [<
range
>|MIN|MAX|DEF|AUTO
[,<
resolution
>|MIN|MAX|DEF]]
configures the multimeter for dc:dc ratio
measurements with the specified range and resolution.
The ratio is calculated from the voltage applied to the HI and LO input terminals
divided by the reference voltage applied to the “Sense” HI and LO terminals.
Autoranging is automatically selected for the reference voltage measurement on the
“Sense” HI and LO terminals. The specified range in the command applies to the
signal connected to the HI and LO input terminals.
Note
Autorange on the “Sense” terminals is from 100mV to 10V range only. Maximum
voltage you can apply to the “Sense” terminals is 10V.
Parameters
Comments
•
To select a standard measurement range, specify
range
as the input signal's
maximum expected voltage. The multimeter then selects the correct range to
accept the input.
•
The
AUTO
or
DEFault
option for the
range
parameter enables autorange. The
DEFault
option for
resolution
defaults the integration time to 10 PLC.
•
The
MIN
and
MAX
parameters select the minimum or maximum values for
range
and
resolution
:
For
range
:
MIN
= 100mV;
MAX
= 300V.
For
resolution
:
MIN
selects the best resolution (the smallest value) for the
selected range.
MAX
selects the worst resolution (the largest value) for the
selected range.
DC:DC RATIO =
dc signal voltage
dc reference voltage
-------------------------------------------------
=
Hi and LO input
Sense HI and LO input
-------------------------------------------------------
Parameter Name
Parameter Type
Range of Values
Default Units
<
range
>
(HI-LO input)
numeric
100mV|1V|10V|100V|300V|
MIN|MAX|DEF|AUTO
volts
<
resolution
>
numeric
resolution|
MIN|MAX|DEF
volts
Содержание Agilent E1412A
Страница 2: ......
Страница 10: ...8 Contents Notes...
Страница 14: ...12 Notes...
Страница 15: ...13 Notes...
Страница 16: ...14 Notes...
Страница 20: ...18 Agilent E1412A Multimeter Module Setup Chapter 1 Figure 1 2 Multimeter Measurement Terminals...
Страница 26: ...24 Agilent E1412A Multimeter Module Setup Chapter 1 Notes...
Страница 194: ...192 Agilent E1412A Multimeter Error Messages Appendix B Notes...
Страница 201: ...Index 199 Index Agilent E1412A User s Manual and SCPI Programming Guide...