OUTPut Subsystem
Parameter
Typical Return
{NORMal|INVerted}, default NORMal
NORM or INV
Set output polarity to INVerted:
OUTP:POL INV
l
NORMal:
waveform goes in one direction at the beginning of the cycle;
INVerted:
waveform goes in other.
l
As shown below, the waveform is inverted relative to the offset voltage. The offset voltage remains unchanged
when the waveform is inverted.
l
The
Sync
signal associated with an inverted waveform is not inverted.
OUTPut:SYNC {ON|1|OFF|0}
OUTPut:SYNC?
Disables or enables the front-panel
Sync
connector.
Parameter
Typical Return
{ON|1|OFF|0}, default ON
0 (OFF) or 1 (ON)
Disable front panel
Sync
connector:
OUTP:SYNC OFF
l
Disabling the
Sync
signal reduces output distortion at lower amplitudes.
l
For more details on the
Sync
signal for each waveform function, see
.
l
When
Sync
is disabled, the output level on the
Sync
connector is a logic "low."
l
Inverting a waveform (
) does not invert the
Sync
signal.
OUTPut[1|2]:SYNC:MODE {NORMal|CARRier|MARKer}
OUTPut[1|2]:SYNC:MODE?
Specifies normal
Sync
behavior (NORMal), forces
Sync
to follow the carrier waveform (CARRier), or indicates marker
position (MARKer).
Parameter
Typical Return
{NORMal|CARRier|MARKer}, default NORMal
NORM, CARR, or MARK
Agilent 33500 Series Operating and Service Guide