FUNCtion Subsystem
<
percent
>
Channel 1
Amplitude %
Channel 2
Amplitude %
20
100
80
l
This command is enabled by
.
l
This setting is stored as part of the instrument state, and it is affected by
.
FUNCtion:ARBitrary:BALance:OFFSet[1|2] {<
volts
>|MAXimum|MINimum}
FUNCtion:ARBitrary:BALance:OFFSet[1|2]? {MAXimum|MINimum}
This command requires the IQ Player option.
Specifies the offset (in volts) added to the dual arbitrary waveform offset for the specified channel.
Parameter
Typical Return
A floating point value, limited by the dual arbitrary wave-
form amplitude.
+1.00000
Load an arbitrary waveform from the USB drive and set up the balance gain (channel 2 down by 1.02%) and balance
offsets (120 mV for channel 1 and -38 mV for channel 2):
FUNC:ARB "USB:\qam32.barb"
FUNC:ARB:BAL:GAIN 1.02
FUNC:ARB:BAL:OFFS1 0.12
FUNC:ARB:BAL:OFFS2 -0.038
FUNC:ARB:BAL ON
l
Both channels must stay on the same amplifier range.
l
This command is enabled by
.
l
This setting is stored as part of the instrument state, and it is affected by
.
FUNCtion:ARBitrary:SKEW[:STATe] <
state
>
FUNCtion:ARBitrary:SKEW[:STATe]?
This command requires the IQ Player option.
Enables or disables skew time compensation (
). This is always OFF for modulated sig-
nals, sweeps, lists, and bursts.
Parameter
Typical Return
{ON|1|OFF|0}, default OFF
0 (OFF) or 1 (ON)
Set the skew time to compensate for channel 1 being behind channel 2 by 140 picoseconds:
FUNCtion:ARBitrary:SKEW:TIME 1.4e-10
FUNCtion:ARBitrary:SKEW ON
226
Agilent 33500 Series Operating and Service Guide
Содержание Agilent 33500 Series
Страница 1: ...Agilent Technologies 33500 Series Waveform Generator Operating and Service Guide ...
Страница 68: ...Output Configuration OUTPUT SYNC SOURCE CH1 CH2 Agilent 33500 Series Operating and Service Guide 67 ...
Страница 410: ...Block Diagram Block Diagram Agilent 33500 Series Operating and Service Guide 409 ...
Страница 429: ......