SETup:BERRor
SETup:BERRor:MANual:DELay
SETup:BERRor:SLControl
Function
Sets/queries the number of frames the test set will use to correlate uplink information bits with
downlink information bits when loop delay control mode is manual (AUTO OFF). To set the delay
mode to manual, refer to
“SETup:BERRor:LDControl:AUTO” on page 388
This value is displayed in the Speech Frames Delay field when Auto is not displayed. (If you want
to display this value and Auto is currently displayed, press the front-panel key labeled OFF).
Refer to
“Bit Error Measurement Description” on page 48
for a description of frame delay and
how it is used in this measurement.
Setting
Range: 1 to 15
Resolution : 1
Query
Range: 1 to 15
Resolution : 1
*RST Setting
5
Programming Example
OUTPUT 714;"SETUP:BERROR:MANUAL:DELAY 4" !Set delay of 4 speech frames.
Function
Selects/queries the Signalling loopback control state for an BER measurement.
When signalling loopback control is set to on, the test set will automatically send the loopback for
Type A (residual) or Type B (non-residual)
loopback to the MS, based on the measurement
type selected, and then set loopback to off when the measurement is complete.
The loopback type is controlled manually from the Mobile Loopback F12 key, see
“CALL:TCHannel:LOOPback” on page 291
for a program example and details about the
command.
Setting
Range: 1 | ON | 0 | OFF
Query
Range: 1 | 0
*RST
1 | ON
Programming Example
OUTPUT 714;”SETUP:BERROR:SLCONTROL ON” ! Test set will send
! loopback type automatically