Technical Information
J5 - In-Out
17
TV 401
/301 MS
User Manual / 87-901-013-01
(A)
219/
264
Tab. 3
PIN N.
SIGNAL NAME INPUT/OUTPUT
1 START/STOP
(+)
IN
2 START/STOP
(-)
IN
3 INTERLOCK
(+)
IN
4 INTERLOCK
(-)
IN
5 SPEED
SETTING
(+)
IN
6 SPEED
SETTING
(-)
IN
7
SOFT START (+)
IN
8
SOFT START (-)
IN
9 +24
Vdc
OUT
10 SPARE
11
PROGRAMMABLE SET POINT
OUT
12 SPARE
13 FAULT
OUTPUT
OUT
14 PROGRAMMABLE
ANALOG
SIGNAL (+)
OUT
15 GROUND
PROGRAMMABLE ANALOG SIGNAL (-)
OUT
Signal Description
START/STOP
: input signal to start or stop the pump. With the
supplied cover connector the START/STOP (+) signal is connected to
the +24 Vdc pin and the START/STOP (-) signal to the GROUND pin:
in this condition the pump automatically starts as soon as the
controller recognises the input supply ("Plug & Pump").
INTERLOCK
: input signal to control the pump rotation. With the
supplied cover connector the INTERLOCK (+) signal is connected to
the +24 Vdc pin and the INTERLOCK (-)signal to the GROUND pin.
Содержание 869-8928R003
Страница 3: ...TV 401 301 MS TV 401 301 MS User Manual 87 901 013 01 A 3 264 TV 401 301 MS...
Страница 4: ...TV 401 301 MS 4 264 TV 401 301 MS User Manual 87 901 013 01 A...
Страница 224: ...17 Technical Information J5 In Out 224 264 TV 401 301 MS User Manual 87 901 013 01 A Figure 19 Case 1...
Страница 244: ...17 Technical Information Serial Cable Installation 244 264 TV 401 301 MS User Manual 87 901 013 01 A Figure 32...
Страница 258: ...17 Technical Information Accessories and Spare Parts 258 264 TV 401 301 MS User Manual 87 901 013 01 A...
Страница 259: ......
Страница 260: ......
Страница 261: ......
Страница 262: ......
Страница 263: ......