STATus Subsystem
When queried, the largest value that can be returned is
32767. This is because the most-significant register bit
cannot be set true.
Example
OUTPUT 720;”:STATUS:OPER:PTRansition 16”
:STATus:PRESet
Presets the enable registers and the PTRansition and
NTRansition filters.
Attribute Summary
Preset
State: none
*RST State: none
SCPI Compliance: standard
Command Only
Description
The PRESet command is defined by SCPI to affect the
enable register. If you want to clear all event registers
and queues, use the *CLS command.
Example
OUTPUT 720;”:STATUS:PRESET”
Status Node
Preset Value
Operation enable register
0
Questionable enable register
0
PTRansition filters
32767
NTRansition filters
0