18-14
Measure Commands
CGRade:CROSsing
Example
10 OUTPUT 707;”:SYSTEM:HEADER OFF”
20 OUTPUT 707;”:MEASURE:CGRADE:CRATIO? PERCENT”
CGRade:CROSsing
Command
:MEASure:CGRade:CROSsing [{CHANnel<N> | FUNCtion<N> | CGMemory}]
Measures the crossing level percent of the current eye diagram on the color grade or gray
scale display. The data for color grade display is the same as for gray scale display. If the
source is not set, the lowest numbered signal that is on will be the source of the measure-
ment.
Mode
Eye mode only. Ensure that the eye type is set to NRZ. See
Query
:MEASure:CGRade:CROSsing? [{CHANnel<N> | FUNCtion<N> | CGMemory}]
The query returns the crossing level percent of the current eye diagram on the color grade or
gray scale display.
Returned Format
[:MEASure:CGRade:CROSsing] <value>[,<result_state>]<NL>
<value> is the crossing level. If SENDvalid is ON, the <result_state> is returned with the
measurement result. Refer to
for a list of the result states.
Example
10 OUTPUT 707;”:SYSTEM:HEADER OFF”
20 OUTPUT 707;”:MEASURE:CGRade:CROSsing?”
CGRade:DCDistortion
Command
:MEASure:CGRade:DCDistortion <format>[,{CHANnel<N> | FUNCtion<N> | CGMemory}]
Measures the duty cycle distortion on the eye diagram of the current color grade or gray scale
display. The parameter specifies the format for reporting the measurement. The data for
color grade display is the same as for gray scale display. If the source is not set, the lowest
numbered signal that is on will be the source of the measurement. <format> is {TIME | PER-
Cent}.
Mode
Eye mode only. Ensure that the eye type is set to NRZ. See
Query
:MEASure:CGRade:DCDistortion? <format> [,{CHANnel<N> | FUNCtion<N> | CGMemory}]
The query returns the duty cycle distortion of the color grade or gray scale display.
Returned Format
[:MEASure:CGRade:DCDistortion] <value>[,<result_state>] <NL>
<value> is the duty cycle distortion. If SENDvalid is ON, the <result_state> is returned with
the measurement result. Refer to
for a list of the result states.
Example
10 OUTPUT 707;”:SYSTEM:HEADER OFF”
20 OUTPUT 707;”:MEASURE:CGRADE:DCDistortion? PERCENT”
CGRade:DCYCle
Command
:MEASure:CGRade:DCYCle [<source>]
Measures the duty cycle of the RZ (Return-to-Zero) eye diagram on the color graded display.
If the source is not set, the lowest numbered signal display that is on will be the source of the
measurement. <source> is {CHANnel<N> | FUNCtion<N> | CGMemory}.
Mode
Eye mode only. Ensure that the eye type is set to RZ. See
.
Содержание 86100A
Страница 18: ...1 14 Introduction Status Reporting Figure 1 4 Status Reporting Data Structures...
Страница 19: ...1 15 Introduction Status Reporting Status Reporting Data Structures continued...
Страница 94: ...2 40 Sample Programs BASIC Programming Examples...
Страница 124: ...4 16 Root Level Commands VIEW...
Страница 125: ...5 DATE 5 2 DSP 5 2 ERRor 5 3 HEADer 5 4 LONGform 5 5 MODE 5 6 SETup 5 7 TIME 5 7 System Commands...
Страница 132: ...5 8 System Commands TIME...
Страница 140: ...6 8 Acquire Commands SWAVeform RESet...
Страница 152: ...7 12 Calibration Commands STATus...
Страница 192: ...11 12 Display Commands SSAVer...
Страница 202: ...12 10 Function Commands VERTical RANGe...
Страница 203: ...13 AREA 13 2 DPRinter 13 2 FACTors 13 3 IMAGe 13 3 PRINters 13 4 Hardcopy Commands...
Страница 316: ...21 12 TDR TDT Commands Rev A 05 00 and Below STIMulus...
Страница 332: ......
Страница 353: ...26 DISPlay 26 2 LOAD 26 2 SAVE 26 3 XOFFset 26 3 XRANge 26 3 YOFFset 26 3 YRANge 26 4 Waveform Memory Commands...