![Agilent Technologies 53210A Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/agilent-technologies/53210a/53210a_options-installation_2867227005.webp)
53210A/53220A/53230A Option Installation
5
53210A/53220A/53230A Option Installation
Moving the Internal Battery (Option 300)
When installing options it may be necessary to temporarily move the
internal battery (Option 300) for easier access. To move the battery if
installed:
1. Remove the two T20 TORX screws and lockwashers holding the Option
300 assembly to the left- hand side panel (as viewed from the rear of the
instrument).
2. Lift up carefully on the left side of the assembly and remove the assem-
bly from the three large tabs holding it on the right side (Figure 3). Dis-
connect the two cables going to the assembly.
3. Lay the assembly on its back to the right side of the chassis and place
the three small tabs on the back side of the three large tabs into the three
slots on the assembly deck.